In compact space connection.Can't reach the control cabinet.Large wires.We understand your work space.Using FieldSense ™ 雷竞技apptechnology Fluke 377 FC and 378 FC clamp table was among the first to let you use only jaw can measure the voltage and current of handheld clamp table.
application
Using FieldSense technology tools are very suitable for use in industrial, residential and commercial facilities troubleshooting and maintenance of the application.
residential | business | industrial | ||
Check whether the circuit is charged before start working | X | X | X | |
Measurement of voltage (FieldSense is used to measure the ac voltage or using the test lead to measure dc voltage) | X | X | X | |
Through the jaw measurement is as high as 1000 A dc current | X | X | X | |
Through measuring up to 2500 a alternating current iFlex accessories | X | X | X | |
To 60 k Ω resistance measurement range | X | X | X | |
Check the circuit on and off | X | X | X | |
Measuring panel branch circuit load | X | X | ||
Will be mapped to the circuit breaker socket | X | X | ||
Measuring the pump and motor or compressor load | X | X | ||
Determination of lighting system on the voltage and current | X | X | ||
Check the switchboard (including feed cable, branch circuit and neutral) of the load and grounding circuit integrity | X | |||
The generator/motor/chiller maintenance and troubleshooting | X | |||
Test of the motor power supply circuit (maximum 1000 ampere) | X | |||
Verify the motor and pump load of the measured values | X | |||
Confirm the transformer load and line voltage | X |
Why use FieldSense in clamp table?
FieldSense is an award-winning breakthrough in voltage measurements by technology.Conventional clamp table by testing for alternating current magnetic field measurements, and FieldSense also by measuring the electric field at the same time measure the voltage.As a 雷竞技appresult, Fluke clamp table in an operation can be through the use of forceps mouth at the same time measure the voltage and current:
- Double screen support for current and voltage measurements at the same time
- Don't need to clamp table to connect to a charged conductor, and therefore can be more safely for voltage measurements
- Fast 3 phase measurement, in order to obtain automatically calculates the relative phase voltage and phase rotation
- Built-in power quality (PQ) in 378 FC indicator, used to monitor power related problems
- 雷竞技appFluke Connect software can realize seamless data transfer and data records, report
How to support FieldSense clamp table is used to measure the voltage or current
- Separate the live wire and neutral wire.
- The black paint test wire clip in any outstanding electrical grounding on the side.
- The clamp clip on the wire.Ensure that wire contact with the yellow part of the jaw, as shown.
- See on the screen is reliable, accurate voltage and current value.
In the jaw and more easy to isolate the control cabinet is used various wires, when many wire banding together generally difficult to isolate.In many cases, the one hand can be used for measurement.
Please note that FieldSense technology in variable frequency drives (VFDS) output does not work.In voltage VFDS output measurement, please use the test lead of the clamp table attached.