A: if it is a true RMS ac multimeter, 17 x or x 8, for example, it is not zero, and should not return to zero.For ac voltage and ac current, true RMS multimeter most has the lowest ac voltage and current index, usually for the range of 3% to 5%.When the signal is above the minimum levels, instrument will meet its accuracy index.Can be found in the user manual part at the back of the technical indicators the index.
Answer: the answer is located in the application of the article "digital multimeter." ""With the features and functions of ABC - a multi-meter.".
A: it refers to the range, the least significant bit of instrument.For example, we use 6000 words A multimeter measuring 120 V ac voltage (A/D converter) from 0 to 5999 words.In order to measure 120 V ac voltage, the instrument must be in 600.0 ac voltage range.The resolution (least significant bit) 0.1 V.(120 V X 1% = 1.2 V + 3 words) = (1.2 V to + 0.3 V) = 1.5 V
A: as the name implies, "Min/Max" (Min/Max) model is a multimeter from the "Min/Max" (Min/Max) record mode began to measure the maximum and minimum of readings.Under normal circumstances, in order to obtain accurate readings, need from 200 to 350 milliseconds or longer period of time the maximum or minimum value measurement signal.They apply to any schema, such as dc voltage, true RMS ac voltage, resistance and current function."Peak" (Peak) model of positive and negative Peak voltage measurement signal.For 120 V ac circuit, peak readings will reach + 169 V and 169 V (for pure sine wave, x 1.414 = 169 V, 120 V).Normally, they can be well used in the peak of 250 microseconds, or for a longer time.
Answer: the instrument measurement is test line resistance, a new set of test line usually 0.1 to 0.3 ohm resistance range.The error of the test line need to subtract from resistance.Some of the more feature-rich instrument will provide the "Relative delta" (Relative difference) (in the final result using actual Δ symbol) mode button, it will be minus the test line error.
A: you can "Save the Memory" (Save the Memory) Save a total of 400 Save most readings.
A: you can up to save a total of 400 records in the memory.By putting a time interval is set to 15 minutes, even if you use all 400 save reading storage location, before need to upload the result to the computer, also can get more weeks.
A: repeat again, "Min/Max" (Min/Max and "Peak" (Peak), respectively, a total of 400, a total of 800 readings.
A: can't.When you select the name, such as "Motor" (Motor), "the Panel (Panel)," Circuit (Circuit) ", "Control" (Control) or "'" (Battery), you need to do is to "Save" (Save), "Record" (Record), "Min Max" (Min/Max) or the "Peak" (Peak) reading placed in the files of the selected folder.A total of 400 still each measurement type.