China

雷竞技appFluke 961 a / 961 b / 961 c temperature and humidity recorder USB type

  • 雷竞技appFluke 961 a / 961 b / 961 c USB Temperature and Humidity Logger
  • 雷竞技appFluke 961 a / 961 b / 961 c USB Temperature and Humidity Logger
  • 雷竞技appFluke 961 a / 961 b / 961 c USB Temperature and Humidity Logger
  • 雷竞技appFluke 961 a / 961 b / 961 c USB Temperature and Humidity Logger
  • 雷竞技appFluke 961 a / 961 b / 961 c USB Temperature and Humidity Logger
  • 雷竞技appFluke 961 a / 961 b / 961 c USB Temperature and Humidity Logger
New product

The main features

  • USB direct reading PDF report, don't need to install the software
  • 32000 groups of data, to meet for a long time
  • Minimum time recording interval to 10 seconds, rapid response to environmental changes of the situation
  • In line with the FDA, data can be traced back
  • A variety of export data and report format
  • 1 meter fall prevention, protection grade IP65
  • Design is small and light, easy to record and read at any time

Produc雷竞技appts overview: Fluke 961 a / 961 b / 961 c temperature and humidity recorder USB type

Read records at any time, at any time, convenient to use

Don't need an雷竞技appother cable, direct use of Fluke 961 comes with a USB interface, can be easily read PDF files automatically generated by the temperature and humidity monitoring, can also be recorder of temperature and humidity data in a table, chart, rapid export in the form of text.Up to 32000 groups of data storage, meet the demand of monitoring for a long time, without frequent export.雷竞技appFluke 961 series USB temperature and humidity recorder is food, medicine, cold chain industry, cold storage temperature and humidity monitoring of convenient tools.

It is recommended to use scene: long time record, according to the need to look at it

  • Cold chain transportation
  • Cold storage verification
  • The food fresh
  • Temporary transfer
  • Ark of air-conditioner is cool
  • Cryogenic storage
Parameters such as start, interval, alarm Settings

The data view and curve analysis

Produc雷竞技appt specifications: Fluke 961 a / 961 b / 961 c temperature and humidity recorder USB type

961 a 961 b, 961 c
Detailed technical indicators
Sensors in the form of built-in The outer The outer
Temperature measurement
The temperature range 30.0 ° and 70.0 ° C C 85.0 ° and 150.0 ° C C 40.0 ° and 85.0 ° C C
The accuracy of + / - 0.4 ° C Plus or minus (0.3 + 0.005 x | | readings) ° C + / - 0.4 ° C
The resolution of the 0.1 ° c.
Humidity measurement
range Between 0% and 100.0% RH NA Between 0% and 100.0% RH
The accuracy of Plus or minus 3% RH (20 to 80% RH @ 25 ° C).
+ / - 5% RH (< 20% RH > 80% RH @ 25 ° C)
NA Plus or minus 3% RH (20 to 80% RH @ 25 ° C).
+ / - 5% RH (< 20% RH > 80% RH @ 25 ° C)
The resolution of the 0.1% RH NA 0.1% RH
Save the data 32000 groups of
Record the time interval 10 seconds to 24 hours
Boot mode Button or PC software
Stop mode Buttons, PC software, or full stop
The alarm threshold As many as three temperature limit and two temperature limit
A humidity cap and a lower limit
Alarm type Single/accumulation
The output report format Directly read PDF (PC), Excel and TXT (via PC software)
General technical indicators
The temperature work - 30 ° C to 70 ° C (host)
storage - 30 ° C to 70 ° C (host)
At an altitude of work 2 000 meters
storage 12 000 m
Relative humidity work 0% RH to 100% RH, the condensation
storage < 75% RH
The power supply The battery type CR2450x1
Battery life 1 year (record @ 15 minutes interval, 25 ° C)
security IEC 610101-1, pollution level 2
Size (length x width x height) 47 mm x 107 mm x 17 mm (excluding external probe)
The weight of the 60 g (including battery) 88 g (including battery) 78 g (including battery)
Protection (IP) rating IEC 60529: IP65
Electromagnetic compatibility (EMC) IEC 61326-1: basic electromagnetic environment;CISPR 11: group 1, A class
Group 1: equipment can produce and/or intentionally use conductive coupling radio frequency energy, it is necessary for internal operation with the device itself.
Class A: equipment is suitable for the family purposes and is not directly connected to the power supply of residential building low voltage network of any device.Because of the conducted interference and radiated interference, electromagnetic compatibility in other environments may be difficult to guarantee.
Caution: this equipment is used for residential environment, in such an environment may not provide adequate radio reception.

Mode雷竞技appl: Fluke 961 a / 961 b / 961 c temperature and humidity recorder USB type

雷竞技appFluke 961 a / 961 b / 961 c

Mod雷竞技appel: Fluke 961 a / 961 b / 961 c temperature and humidity recorder USB type

雷竞技appTemperature and humidity recorder Fluke 961 a USB type

Random standard

  • 雷竞技appFluke 961 a host
  • Mounting bracket and screw
  • hook and loop fasteners

雷竞技appFluke 961 b type USB temperature recorder

Random standard

  • 雷竞技appFluke 961 b host
  • Mounting bracket and screw
  • hook and loop fasteners

雷竞技appFluke 961 c temperature and humidity recorder USB type

Random standard

  • 雷竞技appFluke 961 c host
  • Mounting bracket and screw
  • hook and loop fasteners