The main features

  • Can choose to go or optional external probe, the flexible space constraints
  • Accuracy of + / - 0.4 ℃, plus or minus 3% RH, industrial-grade test requirements
  • 99 groups of da雷竞技appta storage, convenient back to see (only Fluke 972 b)
  • Grip feels comfortable, accord with human body engineering design
  • Strengthening confinement of sensors to ensure safe operation

Produc雷竞技appts overview: Fluke 972 a / 972 b / 972 es temperature and humidity detector

Increases with the increasing measurement, industrial design, inspection is necessary.

Comfort, environmental temperature and humidity is indoor air testing of two crucial test.雷竞技appFluke 972 series temperature and humidity detector can be quickly and easily obtain accurate humidity and temperature data.Streamlined industrial design easy to hold, to streamline the action button without more complex operation, selection of high precision sensor to ensure that the data is reliable.For equipment maintenance and engineering and technical pe雷竞技apprsonnel, HVAC service contractors, research and development and production personnel, and engaged in the indoor air quality (IAQ) evaluation experts, Fluke 972 series is an integral part of the environmental monitoring tool.

Produc雷竞技appt specifications: Fluke 972 a / 972 b / 972 es temperature and humidity detector

972 a 972 b, 972 es
Detailed technical indicators
Sensors in the form of built-in Built-in + external The outer
The temperature range 30.0 ° and 70.0 ° C C 30.0 ° and 70.0 ° C C (built-in sensors);
40.0 ° C to 100 ° C (external sensors)
40.0 ° C to 100 ° C
The temperature accuracy + / - 0.4 ° C Built-in sensors: + / - 0.4 ° C (30 ° C to 70 ° C)
External sensors:
+ / - 0.4 ° C (to 40 ° C to 90 ° C).
+ / - 0.5 ° C (90 ° C to 100 ° C)
+ / - 0.4 ° C (to 40 ° C to 90 ° C).
+ / - 0.5 ° C (90 ° C to 100 ° C)
The temperature resolution 0.1 ° c.
The dew point temperature range N/A 40.0 ° C to 100 ° C N/A
The resolution of the N/A 0.1 ° c. N/A
Wet bulb temperature range N/A 20.0 ° and 60.0 ° C C N/A
The resolution of the N/A 0.1 ° c. N/A
humidity range Between 0% and 99.9% RH
The accuracy of + / - 3% RH (20% RH to 80% RH @ 25 ° C).
+ / - 5% RH (< 20% RH > 80% RH @ 25 ° C)
The resolution of the 0.1% RH
Save the data N/A Yes, up to 99 sets of data N/A
According to Line 2 LCD display with backlight There is no
Automatic shutdown Automatic shutdown after 20 minutes without any operation N/A
General technical indicators
The temperature work - 30 ° C to 70 ° C To 40 ° C to 70 ° C
storage - 30 ° C to 70 ° C, < 80% RH (including battery) To 40 ° C to 70 ° C, < 80% RH
At an altitude of work 2000 m
storage 12000 m
Relative humidity work 0% RH to 99% RH
storage < 80% RH
The power supply The battery type Section 2 AAA batteries -
Battery life 1000 hours of continuous work, no backlight -
security IEC61010-1, level 2 pollution
Size (length x width x height) 58 x 211 x 40 mm 264 x x 28 mm 33
The weight of the 172 g (model) 127 g
Electromagnetic environment (EMC) IEC 61326-1: portable, electromagnetic environment: IEC 61326-2-2;CISPR 11: group 1, A class
Group 1: equipment can produce and/or intentionally use conductive coupling radio frequency energy, it is necessary for internal operation with the device itself.
Class A: equipment is suitable for the family purposes and is not directly connected to the power supply of residential building low voltage network of any device.Because of the conducted interference and radiated interference, electromagnetic compatibility in other environments may be difficult to guarantee.
Caution: this equipment is used for residential environment, in such an environment may not provide adequate radio reception.
Protection (IP) rating IEC 60529: IP30, non-working state

Mode雷竞技appl: Fluke 972 a / 972 b / 972 es temperature and humidity detector

雷竞技appFluke 972 a / 972 b / 972 es

Mod雷竞技appel: Fluke 972 a / 972 b / 972 es temperature and humidity detector

雷竞技appFluke 972 a temperature and humidity detector

Random standard

  • 雷竞技appFluke 972 a host
  • Black soft package

雷竞技appFluke 972 b, temperature and humidity detector

Random standard

  • 雷竞技appFluke 972 b host
  • 雷竞技appFluke 972 es external sensors
  • Black soft package

雷竞技appFluke 972 es external temperature and humidity sensor

Random standard

  • 雷竞技appFluke 972 es external sensors