雷竞技appFluke 972 a / 972 b / 972 es temperature and humidity detector
The main features
- Can choose to go or optional external probe, the flexible space constraints
- Accuracy of + / - 0.4 ℃, plus or minus 3% RH, industrial-grade test requirements
- 99 groups of da雷竞技appta storage, convenient back to see (only Fluke 972 b)
- Grip feels comfortable, accord with human body engineering design
- Strengthening confinement of sensors to ensure safe operation
Produc雷竞技appts overview: Fluke 972 a / 972 b / 972 es temperature and humidity detector
Increases with the increasing measurement, industrial design, inspection is necessary.
Comfort, environmental temperature and humidity is indoor air testing of two crucial test.雷竞技appFluke 972 series temperature and humidity detector can be quickly and easily obtain accurate humidity and temperature data.Streamlined industrial design easy to hold, to streamline the action button without more complex operation, selection of high precision sensor to ensure that the data is reliable.For equipment maintenance and engineering and technical pe雷竞技apprsonnel, HVAC service contractors, research and development and production personnel, and engaged in the indoor air quality (IAQ) evaluation experts, Fluke 972 series is an integral part of the environmental monitoring tool.
Produc雷竞技appt specifications: Fluke 972 a / 972 b / 972 es temperature and humidity detector
972 a | 972 b, | 972 es | ||
Detailed technical indicators | ||||
Sensors in the form of | built-in | Built-in + external | The outer | |
The temperature range | 30.0 ° and 70.0 ° C C | 30.0 ° and 70.0 ° C C (built-in sensors); 40.0 ° C to 100 ° C (external sensors) |
40.0 ° C to 100 ° C | |
The temperature accuracy | + / - 0.4 ° C | Built-in sensors: + / - 0.4 ° C (30 ° C to 70 ° C) External sensors: + / - 0.4 ° C (to 40 ° C to 90 ° C). + / - 0.5 ° C (90 ° C to 100 ° C) |
+ / - 0.4 ° C (to 40 ° C to 90 ° C). + / - 0.5 ° C (90 ° C to 100 ° C) |
|
The temperature resolution | 0.1 ° c. | |||
The dew point temperature | range | N/A | 40.0 ° C to 100 ° C | N/A |
The resolution of the | N/A | 0.1 ° c. | N/A | |
Wet bulb temperature | range | N/A | 20.0 ° and 60.0 ° C C | N/A |
The resolution of the | N/A | 0.1 ° c. | N/A | |
humidity | range | Between 0% and 99.9% RH | ||
The accuracy of | + / - 3% RH (20% RH to 80% RH @ 25 ° C). + / - 5% RH (< 20% RH > 80% RH @ 25 ° C) |
|||
The resolution of the | 0.1% RH | |||
Save the data | N/A | Yes, up to 99 sets of data | N/A | |
According to | Line 2 LCD display with backlight | There is no | ||
Automatic shutdown | Automatic shutdown after 20 minutes without any operation | N/A | ||
General technical indicators | ||||
The temperature | work | - 30 ° C to 70 ° C | To 40 ° C to 70 ° C | |
storage | - 30 ° C to 70 ° C, < 80% RH (including battery) | To 40 ° C to 70 ° C, < 80% RH | ||
At an altitude of | work | 2000 m | ||
storage | 12000 m | |||
Relative humidity | work | 0% RH to 99% RH | ||
storage | < 80% RH | |||
The power supply | The battery type | Section 2 AAA batteries | - | |
Battery life | 1000 hours of continuous work, no backlight | - | ||
security | IEC61010-1, level 2 pollution | |||
Size (length x width x height) | 58 x 211 x 40 mm | 264 x x 28 mm 33 | ||
The weight of the | 172 g (model) | 127 g | ||
Electromagnetic environment (EMC) | IEC 61326-1: portable, electromagnetic environment: IEC 61326-2-2;CISPR 11: group 1, A class | |||
Group 1: equipment can produce and/or intentionally use conductive coupling radio frequency energy, it is necessary for internal operation with the device itself. Class A: equipment is suitable for the family purposes and is not directly connected to the power supply of residential building low voltage network of any device.Because of the conducted interference and radiated interference, electromagnetic compatibility in other environments may be difficult to guarantee. Caution: this equipment is used for residential environment, in such an environment may not provide adequate radio reception. |
||||
Protection (IP) rating | IEC 60529: IP30, non-working state |
Mode雷竞技appl: Fluke 972 a / 972 b / 972 es temperature and humidity detector
Mod雷竞技appel: Fluke 972 a / 972 b / 972 es temperature and humidity detector
雷竞技appFluke 972 a temperature and humidity detector
Random standard
- 雷竞技appFluke 972 a host
- Black soft package
雷竞技appFluke 972 b, temperature and humidity detector
Random standard
- 雷竞技appFluke 972 b host
- 雷竞技appFluke 972 es external sensors
- Black soft package
雷竞技appFluke 972 es external temperature and humidity sensor
Random standard
- 雷竞技appFluke 972 es external sensors