雷竞技appFluke 975 multi-function environmental measuring instrument
The main features
雷竞技appFluke 975 provides incomparable HVAC series measurement functions, create convenient conditions for HVAC technicians to work, to help them quickly and accurately finish the work, and keep the Fluke virtue instrument is convenient to use, durable.
- Measured at the same time, record, and the use of high brightness, backlit LCD displays for temperature, humidity, CO2, CO.
- One-click airflow 雷竞技appand velocity measurement, with a probe (only Fluke 975 v)
- Wet bulb and dew point temperature
- % outside air
- CO2 and CO field calibration function
- Boot self-check function
- Automatic backlit display
- Automatic pressure change compensation
- Show all of the measuring and calculating the average minimum/maximum/reading
- Multilingual user interface
- Metric or standard units
- The alarm sound or visual threshold
- Rich in intermittent or continuous data recording function, can be downloaded to PC through USB interface.
- Keyboard lock, in order to ensure safety.
- Con雷竞技apptains FlukeView Forms ® software (belong to the standard configuration section of Fluke 975 v, Fluke 975 should be optional.)
Produc雷竞技appts overview: Fluke 975 multi-function environmental measuring instrument
A tool, a variety of functions.
雷竞技appFluke 975 AirMeter measuring tools combine five powerful functions in one, strong, durable, easy to use, make indoor air monitoring to rise to a new level.Use雷竞技app Fluke 975, HVAC ventilation Settings can be adjusted to better, meet ASHRAE62 recommended standards.It can take the initiative to monitor production status, quickly and accurately in the first solve the problem of impact living comfort.雷竞技appFluke 975 measuring range includes:
- The temperature
- The velocity
- humidity
- CO2
- CO
Flu雷竞技appke 975 AirMeter measuring tool can be used to:
- Solve the problem of the using of the space living comfort.
- Check the building HVAC control system running status.
- Determine whether ventilation is sufficient.
- Monitoring of airflow and velocity.
- A carbon monoxide leak test dangerous problem.
- Duct section take point method of measurement.
- Optimization of HVAC systems, management of energy cost.
Produc雷竞技appt specifications: Fluke 975 multi-function environmental measuring instrument
Measurement specification | ||
The temperature | range | - 20 ° C to 50 ° C (5 ° F to 122 ° F) |
Display resolution | 0.1 ° C (0.1 ° F) | |
precision | + / - 0.9 ° C / + / - 1.62 ° F (40 ° to 60 ° C) C + / - 0.5 ° C / + / - 1.00 ° F (5 ° C to 40 ° C) + / - 1.1 ° C / + / - 1.98 ° F (20 ° C to 5 ° C) - |
|
Relative humidity | range | Between 10% and 90% relative humidity, without condensation |
Display resolution | 1% | |
precision | Plus or minus 2% relative humidity (relative humidity from 10% to 90% relative humidity) | |
Air velocity | range | 50.0 FPM - 3000 FPM 0.25 m/s to 15 m/s |
Display resolution | 1 FPM (0.005 m/s) | |
precision | Plus or minus 4% or 4 FPM creates Plus or minus 4%, or 0.02 m/s that creates greater value |
|
1. The accuracy specification only the effective rate of more than 50 FPM readings. | ||
C0 | range | 0 to 500 PPM |
Display resolution | 1 PPM (one over one million) | |
precision | Plus or minus 5% or + / - 3 PPM, take larger value, 20 ° C and Relative humidity of 50% |
|
C02 | range | 0 to 5000 PPM |
Display resolution | 1 PPM (one over one million) |
|
precision | Preheat time 1 minute (total index for 5 minutes), 2.75% + 75 PPM | |
Calculation specification | ||
The dew point temperature | range | - 44 ° C to 50 ° C (47 ° F to 122 ° F) - |
Display resolution | 0.1 ° C (0.1 ° F) | |
precision | Plus or minus 1 ° C (temperature: - 20 ° C to 50 ° C, relative humidity: 40% to 90%) Plus or minus 2 ° C (temperature: - 20 ° C to 50 ° C, relative humidity: 20% to 40%) Plus or minus 4 ° C (relative humidity: 10% to 20%) |
|
Wet bulb temperature | range | - 16 ° C to 50 ° C (3 ° F to 122 ° F) |
Display resolution | 0.1 ° C (0.1 ° F) | |
precision | + / - 1.2 ° C (relative humidity: 20% to 90%, the temperature: - 20 ° to 60 ° C - C) + / - 2.1 ° C (relative humidity: 10% to 20%) |
|
The volume flow (tube) | range | 0-3965 M3 / m (0-140000 CFM) |
Display resolution | 0.001 M3 / min (CFM) | |
precision | Does not apply to: volume flow calculation is only multiplied by catheter area of the average of the data points | |
% outside air (temperature) based | range | 0-100% |
Display resolution | 0.1 | |
% outside air (based on CO2) | range | 0-100% |
Display resolution | 0.1% is not applicable to | |
General specification | ||
Work and storage temperature | - 20 ° C to 50 ° C (4 ° F to 122 ° F) | |
humidity | From 10% to 90% (without condensate) | |
At an altitude of | Up to 2000 meters (6562 feet) | |
Seismic performance | MIL - PRF - 28800 - f: level 2 | |
Multilingual interface | English, French, Spanish, Portuguese and German | |
The battery | Rechargeable lithium ion batteries (main battery), three AA batteries (backup battery) | |
Data records | 25000 records (continuous), 99 records (discrete) | |
Warranty period | A year |
Mode雷竞技appl: Fluke 975 multi-function environmental measuring instrument
雷竞技appFluke 975 Air Meter ™
Manual + 雷竞技appresource: Fluke 975 multi-function environmental measuring instrument
- 雷竞技appFluke975 function introduction | application cases
- 雷竞技appFluke975 | application cases in hvac
- 雷竞技appFluke975 | application cases in energy saving
- How to detect carbon monoxide?(F975) | application cases
- Fluke products how to monitor the data center environmental indicators _F975_TiS20 | application case
- Energy conservation for HVAC upgrade components of reason