China

雷竞技appMax + / 1 Fluke T5-600/62 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit

  • 雷竞技appMax + / 1 Fluke T5-600/62 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit

The main features

雷竞技appFluke T5 Voltage, Continuity and Current Testers.

  • Automatically measures volts, AC volts DC and with precise digital resolution.
  • 1000 Ω Displays to hold to.
  • Easy and accurate OpenJaw ™ current measurement.
  • Continuity beeper.
  • Rugged enough to withstand a 10 ft (3 m) drop.
  • 600 V model.
  • Auto off mode to conserve 'life.
  • AC current.
  • The Display to hold.
  • All inputs of the T5-600 are protected to CAT III 600 v. EN61010-1 UL, CSA and VDE listed.

雷竞技appFluke 62 MAX +. Small in size. Big on toughness.

  • Dust and water - resistant: IP54 rated.
  • Rugged: 3 m (9.8 ft) drop *.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Short to spot: now.
  • Dual lasers: Identifies the area to be measured.
  • Large, backlit display: top service data easier to read, even in dark areas.
  • C115 Deluxe soft their case with shoulder strap.

Produc雷竞技appts overview: Fluke T5-600/62 Max + / 1 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit

This kit is designed to help electricians and HVAC technicians of solve the problems quicker. Test first for overheated electrical devices using an IR thermometer.Then use electrical test tools to find out more about the problem.

Produc雷竞技appt specifications: Fluke T5-600/62 Max + / 1 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit

雷竞技appFluke T5-600 Voltage, Continuity and Current Tester

Specifications
Jaw opening 12.9 mm (0.5 in)
Max wire size 1/0 THHN cable
The Current range AC RMS 0 to 100.0 A
Accuracy of AC current (50/60 Hz) 3% plus or minus 3 counts
AC Response Averaging
Voltage range AC 0 to 600 V
Accuracy of AC voltage 1.5% plus or minus 2 counts
Voltage range of DC 0 to 600 V
Accuracy DC voltage The count 1% plus or minus 1
To hold the range 0 to 1000 Ω
Continuity beeper threshold On the at < 25 Ω, off the at > 400 Ω
Volts indicator LED threshold Guaranteed on by 30 V AC
Environmental Specifications
Operating temperature - 10 ° C to 50 ° C
Storage temperature - 30 ° to 60 ° C C
Humidity (without condensation) 0% to 95% (5 ° to 30 ° C C);0% to 75% (30 ° C to 40 ° C);
0% to 45% (40 ° C to 50 ° C)
Dust/water to hold Yes
Operating led 2000 meters Max
Temperature coefficient 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Safety Specifications
Measurement Category IEC 61010-2-032, IEC61010-2-033: the CAT III 600 V, 100 A ac
Agency approvals CSA and TUV
Maximum voltage 600 V between any terminal and earth ground
Mechanical and General Specifications
The Size 51 x 30.5 x 203 mm
Weight 300 g
giant Two years -
'life 200 hour any zinc chloride, 400 hour alkaline
'type 2 x AA
Low 'indicator Yes
The Current sensor opening The 12.9 mm
Calibration cycle 1 year
The Test leads The Type Heavy duty, flexible leads rated for the use of 1000 V.
Field replaceable leads the terminate male shrouded in banana plugs
The Probes One red and One black.
Detachable Slim - Reach ™ probe tips
Styles TP1 Slim Reach ™ test brobes
Safety Specifications
Safety CAT IV 600 V, the CAT III, 1000 V
Maximum voltage 1000 V AC RMS from earth to the ground, in the compliance with EN61010


雷竞技appFluke 62 MAX + Infrared Thermometer

Specifications
Temperature range - 30 ° C to 650 ° C (22 ° F to 1202 ° F) -
Accuracy + / - 1.0 ° C or plus or minus 1.0% of reading, whichever is greater
- 10 ° C to 0 ° C: + / - 2.0
- 30 ° C to - 10 ° C: + / - 3.0
The Response time (95%). < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical resolution Whoever (calculated at 90% energy)
The Display resolution 0.1 ° C (0.2 ° F)
Repeatability of readings Plus or minus 0.5% of reading or < plus or minus 0.5 ° C (1 ° F), whichever is greater
The Power AA '
'life 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
The Size 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating temperature 0 ° C to 50 ° C (32 ° F to 122 ° F)
Storage temperature - 20 ° to 60 ° C (C - 4 ° F to 140 ° F), (without ')
Operating humidity 10% to 90% RH non - condensing at 30 ° C (86 ° F)
Operating led 2000 meters above mean sea level
Storage led 12000 meters above mean sea level
The IP rating IP 54 per IEC 60529
The Drop test 3 meters
Vibration and shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:6 now EN 61326-06
Standards and agency approval The Compliance EN/IEC 61010-1:2001
Laser safety The FDA and EN 60825-1 Class II

Mode雷竞技appl: Fluke T5-600/62 Max + / 1 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit

雷竞技appFluke T5 - MAX + 600/62
雷竞技appMax + / 1 Fluke T5-600/62 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit

Includes:

  • 雷竞技appFluke T5-600
  • 雷竞技appFluke 62 MAX + IR Thermometer