雷竞技appFluke Ti300 infrared thermal imager
The main features
- The雷竞技app Fluke IR - Fusion ® technology, through the AutoBlend ™ mode, can test the faster and communicate the problems
- Through the wireless image transmission, faster transfer directly to your PC, Apple ® iPhone ® or the ®
- 雷竞技appFluke Connect ® application - found.Save.To be Shared.All the data, the scene for a quick
- Single hand operation, easy to use user interface
- Rugged 640 x480 resolution capacitive touch screen, can be carried out fast navigation menu
- Use the IR - PhotoNotes ™ annotation system, additional digital image capture, to show the position or more detailed information on site
- More advanced display output options, through to the PC or high resolution monitor for video streaming transmission (USB and HDMI) for details
- By recording and comments, can save the additional detailed information in the image file
- Optional replaceable lens has greater flexibility in other applications
- The intelligent battery rechargeable and field replacement, can display power level LED display, can provide better flexibility
- 5 million pixels industrial digital camera performance, can provide high-definition image quality
- Built-in SmartView ® and SmartView mobile software application analysis and report
Produc雷竞技appts overview: Fluke Ti300 infrared thermal imager
High performance, quickly and easily
Technological change.We don't want is to make y雷竞技appou feel you missed important innovation, therefore Fluke Ti300 thermal imager is designed to adapt to this change.
The future is rooted in its genes.You can through the wireless test and measurement speed, and connected to other wireless devices.If you in the future will use the thermal imager, then make sure it can keep pace with the footsteps of the future.
Autofocus function.Ensure focus for each image
雷竞技appFluke Ti400 thermal imager with LaserSharp ™ autofocus function, perfect focus image can be obtained.Each time each thermal imager users know: in the infrared detection, important is to ensure that focus.If there is no accurate image focus, temperature measurement may be inaccurate, sometimes even a difference of 20 degrees, so it is easy to leak problem.LaserSharp autofocus system can accurately focus on target.In front of the focusing laser is used to calculate the system and the distance between the target.The red laser points on an ongoing flaw detection equipment, and then pull and release the trigger, to get a clear picture of perfect focus.
Compatible c雷竞技apponnection type test tool suite Fluke Connect ®
雷竞技appFluke Connect ® is a can let you don't have to leave the scene can keep in contact with the entire team of wireless testing system.雷竞技appFluke Connect ShareLive ™ video call to keep your device has been normal operation.Without leaving our testing site responses immediately communication key data, and can be obtained and additional work for approval.Immediate use to save time and improve production efficiency.For details, please login雷竞技appflukeconnect.com.
Provide on-site installation telephoto and wide Angle lens, realize extra special application versatility;Voice comments are no longer need a pen and paper.
雷竞技appFluke SmartView ® software included all the time, without any additional cost.
Produc雷竞技appt specifications: Fluke Ti300 infrared thermal imager
The main features | |
Spatial resolution IFOV () | 1.75 mRad |
The detector resolution | 240 x180 (43200 pixels) |
Field of view | 24 ° 17 ° V H x |
The minimum distance | 15 cm (about 6 inches) |
Optional lens | Telephoto lens, wide-angle lens |
Af system | LaserSharp ® autofocus system can continuous af images and manual focus |
Laser range finder | There are |
A wireless connection | Com雷竞技apppatible with Fluke Connect ® application.A wireless connection至 PC、iPhone® 和 iPad®(iOS 4s 及更新版本),Android™ 4.3 及更新版本,WiFi 连接至 LAN¹ |
IR - Fusion ® infrared optical Fusion technology | IR - Fusion ® AutoBlend ™ mode and picture in picture mode |
display | Capacitive touch screen 3.5 -inch diagonal, horizontal color VGA (640 x 480), LCD backlight |
design | Suitable for one-handed use comfortable and durable design |
Thermal degree (NETD) | 30 ° C target temperature, 0.05 ° C (mK) 50 or less |
Temperature measurement range | - 20 ° C to + 650 ° C (4 ° F to 1202 ° F) + |
With a built-in digital camera (visible light) | 5 million pixels industrial performance |
Frame frequency | 9 Hz |
Data storage and image capture | |
Selection of storage | Removable from the micro SD memory card to keep, ram, USB function, connect via USB to computer directly to the download |
The image file format | The radiation (. BMP or jpeg) or total radiation (. Is2) The radiation survey (BMP, JPG and. Avi) file without using the analysis software |
SmartView ® software | SmartView ® so雷竞技appftware, Fluke Connect ® creates and SmartView ® mobile applications - comprehensive analysis and reporting software |
Voice note | Longest 60 seconds per image recording;Can playback view on thermal imager |
IR - PhotoNotes ™ | There are |
Video recording | Standard and radiation |
Streaming video (remote display) | Connect with PC through USB or WiFi hotspot or via HDMI and compatible with HDMI connection screen |
Automatic capture (temperature and interval) | There are |
The battery | |
Replacement, rechargeable batteries (can live) | Two pieces of intelligent battery lithium ions, through five lattice LED display to indicate that the power level |
Battery charging system | Two-seater battery charger or within the thermal imager.Optional 12 V car battery adapter |
Temperature measurement | |
precision | Plus or minus 2 ° C or 2% (25 ° C, take readings larger value) |
Screen emissivity correction | Is (number) and form |
The screen reflection background temperature compensation | There are |
The screen transmission correction | There are |
General technical indicators | |
The palette | 8 standards and 8 Ultra Contrast ™ : iron oxide red, blue and red, high Contrast, amber, amber, hot metal, gray, gray |
Color alarm (alarm temperature) | High temperature, low temperature and isotherm |
Point temperature | Hot and cold spots |
User definable point mark | In the camera and Smartview ® software user can specify three points |
The middle box | Extensible/shrinkage measuring box with MIN - AVG - MAX (low - medium - high) three temperature |
drop | Designed to withstand 2 meters (6.5 feet) of drop height (when using the standard lens) |
Size (height x width x length) | 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in) |
Weight (including battery) | 1.04 Kg (2.3 lb) |
Shell protection grade | IP54 (dustproof sealing protection, all-round waterproof) |
Warranty period | Two years (standard), can also be extended warranty |
note | |
C雷竞技appreates Fluke Connect ® is not in all countries/regions are provided |
Mode雷竞技appl: Fluke Ti300 infrared thermal imager
Include:
- Equipped with standard infrared thermal imager
- The ac power and battery charger (including power adapter)
- Two durable lithium ion intelligent battery pack
- The USB cable
- HDMI video line
- Free downloadSmartView ® software
- Solid hard carry bag
- Soft transport package
- With adjustable hand
- The warranty card
- International adapter kit (only 9 Hz)
Manual + 雷竞技appresources: Fluke Ti300 infrared thermal imager
- Ti200 Ti300, Ti400 Ti450, Ti450SF6, Ti480 | user manual
- Radio Frequency Data Class A | instructions page
- Ti200 Ti300, Ti400 Ti450, Ti450SF6, Ti480 | quick reference guide
- Ti200 Ti300, Ti400 Ti450, Ti450SF6, Ti480 statement | non-volatile memory
- Ti200 Ti300, Ti400 Ti450, Ti450SF6, Ti480 | to information security