雷竞技appFluke Ti480 PRO infrared thermal imager
The main features
- The more visual sensitivity to temperature difference of ascension
- Use clear screen image, multiple rectangular mark and nine palette, easier to display and diagnose the problem
- More intuitive interface, touch screen interface is improved and user testing
- Using intelligent interchangeable lens, to show more flexible since the childhood goal - no need for calibration, compatible with 2 times and 4 times long, wide Angle and macro lens
- Using MultiSharp ™ multipoint focusing function, can be taken for the entire field of a clear and precise focus images
- Instant get focus for a specified target image.LaserSharp ® af USES its built-in laser rangefinder are calculated and displayed with the distance between the specified target
- Using super pixel features four times pixel data, and capture more images, and combine in the images, to generate a picture of 1280 x 960 images
- Save time - wirelessly, di雷竞技apprectly from the thermal imager to image synchronization Fluke Connect ® system, or work order and attached to the asset record
- Use the IR - PhotoNotes ™ and voice notes to reduce the need to take notes
Produc雷竞技appts overview: Fluke Ti480 PRO infrared thermal imager
Improve the sensitivity of the differences are more visual
|
|
|
|
It is easier to visualize and diagnose the problem
|
|
|
Old user interface |
More intuitive visual interface
|
|
To show more flexible goal, since the childhood
|
|
A Ti480 PRO, don't have to worry about focus.Using MultiSharp ™ focus, you can af images over the whole field of view, even the fuzzy goal can also completely.Thermal imager will shoot more image and combine in the images, allows you to focus clearly and accurately the nearby and distant goal.Using super pixel function to view more details, offer 4 times of the pixel data.Use software and SuperResolution, you can view the image resolution of 1280 x 960. |
|
Sav雷竞技appe time by Fluke Connect ® system You can wirelessly, directly from the thermal imager to image synchronization雷竞技appFluke Connect ®Records or work order system, and attached to the asset.At the same time at the scene of the maintenance and office or off-site location access maintenance records, to make decisions faster and achieve real-time collaboration between team members.Can also be thermal imager display real-time transmission to the content of the smart phone or PC and remote control of thermal imager. |
|
Using the support wireless testin雷竞技appg tools to capture, measure and measurement results will be saved to the smartphone on the Fluke Connect ® application. |
Asset analysis dashboard: more complex data easily. |
Produc雷竞技appt specifications: Fluke Ti480 PRO infrared thermal imager
The main features | |
Equipped with a standard lens IFOV (spatial resolution) | 0.93 mRad, D: S 1065:1 |
The detector resolution | 640 x 480 (307200). |
Super pixel function | Capture and combined with 4 multiples which generate 1280 x 960 (614400 pixels) image |
MultiSharp ™ more focus | There, we took the entire field of view focal near and far focus images |
LaserSharp ® laser automatic focus | Have to get clear images of always focus. |
Laser range finder | There is, to calculate the distance to the target to obtain a precise focus images, and displayed on the screen this distance |
Advanced manual focus function | There are |
Durable touch screen | 3.5 inches (horizontal) 640 x 480 LCD |
Suitable for one-handed use comfortable and durable design | There are |
Digital zoom | 2 times and 4 times |
Temperature measurement | |
Temperature measurement range (10 ° C below not calibration) | - 10 ° C to 1000 ° C (14 ° F to 1832 ° F) |
precision | Plus or minus 2 ° C or 2% (in nominal temperature of 25 ° C, take large number) |
Thermal sensitivity (NETD) * | 0.05 ° C (mK) 50 or less, the target temperature 30 ° C |
Screen emissivity correction | Is (number) and form |
The screen reflection background temperature compensation | There are |
The screen transmissivity correction | There are |
*The best |
A wireless connection | |
To connect to PC, iPhone ® and the ® (iOS 4 s and updated version), and the Android ™ and updated version 4.3, WiFi to connect to a LAN (if any) | |
Com雷竞技apppatible with Fluke Connect ® application | *, Connect the thermal imager 雷竞技appto smart phones, will take images automatically and upload images to Fluke Connect application for preserving and sharing |
雷竞技appFluke Connect ® optional software | Distributed to the asset has *, the image and create the work order.In a position easily compare measurement type |
雷竞技appFluke Connect ® instant upload | *, Connect the thermal imager to WiFi 雷竞技appnetwork, the architecture of a recording images automatically and upload images to Fluke Connect system for your view on the smart phone or PC |
Co雷竞技appmpatible with Fluke Connect ® tools | *, wirelessly c雷竞技apponnected to support Fluke Connect selected tools and measurement in the thermal imager screen |
IR - Fusion ® infrared optical Fusion technology | |
To add to the visual details of the infrared image | |
AutoBlend ™ mode | Min, Mid, Max IR thermal imager for increasing comprehensive visibility;Continuous variable in the software |
Picture in picture (PIP) | There are |
With a built-in digital camera (visible light) | 5 MP |
The lens | ||
The standard lens | Spatial resolution IFOV () | 0.93 mRad, D: S 1065:1 |
Viewing Angle | 34 ° H x 24 ° V | |
The minimum distance | 15 cm (about 6 inches) | |
IR - Fusion ® infrared optical Fusion technology | Picture in picture and full screen | |
Optional telephoto intelligent camera 2 times | Spatial resolution IFOV () | 0.65 mRad, D: S 1529:1 |
Viewing Angle | 12 ° H x 9 ° V | |
The minimum distance | 45 cm (about 18 inches) | |
IR - Fusion ® infrared optical Fusion technology | Picture in picture and full screen | |
Four times the optional telephoto smart camera | Spatial resolution IFOV () | 0.33 mRad, D: S 2941:1 |
Viewing Angle | 6 ° H x 4.5 ° n | |
The minimum distance | 45 cm (about 18 inches) | |
IR - Fusion ® infrared optical Fusion technology | Picture in picture and full screen | |
Optional wide smart camera | IFOV | 2.62 mRad, D: S 377:1 |
Viewing Angle | 46 ° 34 ° V H x | |
The minimum distance | 15 cm (about 6 inches) | |
IR - Fusion ® infrared optical Fusion technology | Full screen |
Level and the span | Automatic and manual zoom smoothly |
Fast automatic switch between manual and automatic mode | There are |
Manual mode of fast automatic adjustment again | There are |
Minimum range (manual mode) | 2.0 ° C (3.6 ° F) |
The minimum range (automatic mode) | 3.0 ° C (5.4 ° F) |
Data storage and image capture | |
Selection of storage | Portable 4 GB micro SD memory card, 4 GB bu雷竞技appilt-in flash memory, can be saved to the U disk, can be uploaded to the Fluke Cloud ™ permanent storage |
Image capture, view, save mechanism | Single hand image capture, view and save functions |
The image file format | The radiation (. BMP or jpeg) or total radiation (. Is2);. For the radiation (BMP, jpeg and the avi) files, without analysis software |
The memory view | Thumbnails and full screen view |
software | SmartView ® software - a co雷竞技appmprehensive analysis and reporting software and Fluke Connect ® system |
Use SmartView ® software export file format | Bitmap (BMP), GIF, JPEG, PNG, TIFF |
Voice note | Longest 60 seconds per image recording;Can playback view on thermal imager;Optional bluetooth headset but not required |
IR - PhotoNotes ™ image annotation | Is (5 images) |
Text notes | There are |
Video recording | Standard and radiation |
Video file format | The radiation (MPEG encoding. AVI) and total radiation (. IS3) |
Streaming video (remote display) | Have, in the PC, smart phones, or on TV monitor to check the thermal imager display real-time flow through USB, wi-fi hotspots or WiFi network to connect to the PC SmartView ® software;Through WiFi connect雷竞技appion to Fluke on smart phones Connect ® application;Or via HDMI connection to the television monitor |
The remote control operation | Have, through the Sma雷竞技apprtView ® software or Fluke Connect ® mobile applications |
Automatic capture (temperature and interval) | There are |
The battery | |
Replacement, rechargeable batteries (can live) | Two intelligent rechargeable lithium-ion battery pack, through five lattice LED display to indicate that the power level |
Battery life | 2-3 hours/battery (* according to the condition of specific set up and use, the actual working hours may vary) |
Battery charging time | 2.5 hours with |
Battery charging system | Double tank battery charger or thermal imager.Optional 12 V car battery adapter |
Alternating current (ac) work | Through the attached power supply (100 VAC to 240 VAC, 50/60 Hz) using an alternating current work |
Power saving function | The user can choose sleep and shutdown mode |
The palette | |
The standard palette | 9: the rainbow color, rust, blue, red, high contrast, amber, amber, hot metal, gray, gray |
Ultra Contrast ™ palette | 9: the rainbow color, rust, blue, red, high contrast, amber, amber, hot metal, gray, gray |
General technical indicators | |
Frame frequency | 60 Hz or 9 Hz model |
The laser pointer | There are |
Leds (torch) | There are |
Color alarm (alarm temperature) | High temperature, low temperature and isothermal (range) |
Central point temperature measurement | There are |
Point temperature | Hot and cold spots |
User definable point mark | Three user definable point mark |
The middle box | Extensible/shrinkage measuring box with MIN - AVG - MAX (low - medium - high) three temperature display |
The infrared spectral band | 7.5 mu m to 14 microns (long) |
Working temperature | - 10 ° C to + 50 ° C (14 ° F to 122 ° F) |
Storage temperature | - 20 ° C to + 50 ° C (4 ° F to 122 ° F), without the battery |
Relative humidity | Between 10% and 95% with no condensation |
security | IEC 61010-1: overvoltage category II, pollution level 2 |
Electromagnetic compatibility | IEC 61326-1: basic electromagnetic environment.CISPR 11: group 1, A class |
Australia RCM | IEC 61326-1 |
US the FCC | 47 CFR part 15 C in section 15.207, 15.209, all applicable requirements of section 15.249 |
Vibration resistance | G2/0.03 Hz (3.8 g), 2.5 g IEC 68-2-6 |
impact | 25 g, IEC 68-2-29 |
fall | Designed to withstand 2 meters (6.5 feet) of drop height (when using the standard lens) |
Size (height x width x length) | 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in) |
Weight (including battery) | 1.04 kg (2.3 lb) |
Shell protection grade | IEC 60529: IP54 (dustproof sealing protection, all-round waterproof) |
Warranty period | Two years (standard), can also be extended warranty |
Recommended by the calibration cycle | Two years (assuming a normal operation and aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish |
Mode雷竞技appl: Fluke Ti480 PRO infrared thermal imager
- Equipped with standard infrared infrared thermal imager
- The ac power and battery charger (including universal power adapter)
- Two durable intelligent rechargeable lithium-ion battery pack
- USB cable
- HDMI video line
- 4 GB micro SD card
- Solid hard carry case
- With adjustable hand
- Equipped with standard infrared infrared thermal imager
- The ac power and battery charger (including universal power adapter)
- Two durable intelligent rechargeable lithium-ion battery pack
- USB cable
- HDMI video line
- 4 GB micro SD card
- Solid hard carry bag
- With adjustable hand
Manual + 雷竞技appresources: Fluke Ti480 PRO infrared thermal imager
- Ti300 PRO, Ti400 +, Ti400 PRO, Ti401 PRO, Ti450 PRO, Ti480 PRO, Ti450 SF6 | user manual
- Thermal Imagers | to information security
- Ti300 PRO, Ti300 +, Ti400 PRO, Ti400 +, Ti401 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO | non-volatile memory
- Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO | to information security
- Ti300 PRO, Ti400 +, Ti400 PRO, Ti401 PRO, Ti450 PRO, Ti480 PRO, Ti450 SF6 | quick reference guide
- Ti300 PRO, Ti300 +, Ti400 PRO, Ti401 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO | quick reference guide