雷竞技appFluke TiS55 + thermal infrared imager
The main features
- 256 x 192 pixels, offer excellent image quality
- The 3.5 -inch touch screen, reveal more details
- - 20 to 550 ℃ range, suitable for most equipment maintenance and development quality control occasions
- Avoid focusing + manual focus, long-distance scanning big goals/close small target detection, fast switching
- Su雷竞技apppport the Fluke connect and qr code scanning, intelligent management of assets
- Suitable to capture fast moving targets, farewell ghosting (only applicable for 27 hz frame frequency models)
- Strong and durable, 2 m fall prevention
Produc雷竞技appts overview: Fluke TiS55 + thermal infrared imager
Accuracy of upgrades, refactoring is clear
Compared to the original model (TiS55), the new product of the pixel increased 35% *, which will provide users with more clear and accurate measurement results.Synchronous upgrade and thermal sensitivity, can detect tiny temperature changes.
* 256 x 192 pixels (220 x 165 pixels TiS55 +) (TiS55)
Avoid focusing +Is suitable for manual focus, near and far
For quick scan or not familiar with thermal imaging novice, just turn the focusing ring to prime location, can be used from focusing mode, and from the target position of the 1 m or more images, and make sure every time focusing accurately.
For experienced engineers, according to the distance of the object to be tested using manual focus mode to adjust the image, to obtain high quality clear hot like figure, or realize the close observation of small clear goal, such as fever, circuit board components of LED chips, etc.
Collect data, YiJianYuFan
TiS55 + and TiS75 + integrated intelligent function, means that the user can completely lost a notepad, will need all the information attached to the preservation of heat maps, and automatically by machine finishing archive, save precious time for analyzing heat maps, diagnosing the problem:
Voice comments - using bluetooth headset (optional), the voice of every image can be recorded for 60 seconds, real-time and accurate recognition to see everything on the site
IR - PhotoNotes photo comment - took photos of equipment number and other site as a reference when check the heat maps on computer
Asset Tagging equipment intelligent recognition technology -- a qr code scanner, and then start shooting heat, heat will be automatically saved in the current folder under the device name, no manual sorting.All data can be Shared in the cloud and analysis.
At the same time, the new upgrade 3.5 -inch touch screen, more suitable for modern engineers use habits, tap Settings, can be completed through a row will flip infrared/visible light.
27 hzFrame frequency model, record the moment
In addition to the 9 hz frame frequency model, TiS55 + 27 hz is optional frame frequency model, for quick move fast or temperature change of observation target, farewell ghosting.
Fluke infrared thermal image quick selection tool
Packing list
- Thermal imager
- The ac power (with general ac adapter)
- A piece of lithium ion smart battery
- USB cable
- 4 GB micro SD card
- With flexible transport bags and adjustable hand with strong hard portable box
- Provide雷竞技app free download: Fluke Connect ™ software and user manual
Produc雷竞技appt specifications: Fluke TiS55 + thermal infrared imager
The core function | TiS55 + |
Infrared resolution | 256 x 192 (49152 pixels) |
IFOV | 1.91 mRad |
Viewing Angle | 28 ° x 20 ° |
Af system | Manual focus, fixed focal length (focus position location in 1 m) |
A wireless connection | You have, can be connected to PC, iPhone ® and the ® (iOS 4 s and updated version), and the Android ™ and updated version 4.3, as well as wi-fi and LAN (if any) |
Com雷竞技apppatible with Fluke Connect application | *, Connect the thermal imager 雷竞技appto smart phones, will take images automatically and upload images to Fluke Connect application for preserving and sharing |
雷竞技appFluke Connect Assets optional software | Distributed to the asset has *, the image and create the work order.In the same place to easily compare measurement type, whether mechanical, electrical or infrared image |
Asset tag | Scan t雷竞技apphe qr code, Fluke Connect ™ can help you thermal image automatic sorting and filing |
IR - Fusion infrared optical Fusion technology | Continuous integration, 0% to 100%.To add to the visual details of the infrared image |
Picture in picture (PIP) | There are |
display | 3.5 "(8.9 cm diagonal) touch screen 640 x 480 LCD |
Ergonomic design | Specially designed for one-handed use |
Thermal sensitivity | 40 mk |
Level and the span | Automatic and manual zoom smoothly |
Manual mode fast automatic adjustment | There are |
Minimum range (manual mode) | 3 ° C (4.5 ° F) |
The minimum range (automatic mode) | 5 ° C (9.0 ° F) |
With a built-in digital camera (visible) | 640 x 480 |
Frame frequency | 9 Hz or 27 Hz model |
Dew point calculation | There is no |
Data storage and image capture | |
memory | About 500 images |
The external storage | 4 GB SD card or higher (> 1000 images) |
Image capture, view, save mechanism | Single hand image capture, view and save functions |
The image file format | Visible light BMP or JPEG or infrared is2 |
The memory view | There are |
software | 雷竞技appTo access the Fluke Fluke Connect software - Connect the comprehensive analysis and reporting software |
Analysis on the PC and store the heat map data | There are |
Use雷竞技app Fluke Connect software export file format | Is2, BMP, GIF, JPEG, PNG, TIFF |
Voice note | Yes, audio via bluetooth headset profile (HSP) connecting external devices, the longest recorded in 60 seconds. |
IR image annotation | There is.The most optional 1 extra capture visible light image are contained in IS2 file. |
Text notes | After completion of IS2 capture user can use on-screen keyboard input comments. |
Video recording and format | There is no |
The remote control operation | There are |
Automatic capture (temperature and interval) | There is.Optional according to user, the time interval of capture IS2 or Jpeg files. |
The battery | |
Replacement, rechargeable batteries (can live) | Lithium-ion rechargeable batteries |
Battery life | In the case of not use WiFi acuity 3.5 hours continuous working time (the actual battery life depends on the situation to set up and use) |
Battery charging time | 2.5 hours on a full charge |
Battery charging system | Ti SBC3B two-groove battery charger, or charge in the thermal imager.(double groove battery chargers for optional, not the attached) |
Alternating current (ac) work | Through the attached universal power adapter using alternating current work, the output of the adapter is as follows: 15 VDC, 2 A |
Power saving function | Users can choose sleep and turn it off |
Temperature measurement | |
Temperature range (below 10 ℃ uncalibrated) | - 20 ℃ to 550 ° C (below 10 ℃ uncalibrated) |
precision | At 25 ℃ ambient temperature plus or minus 2 ° C or 2% (supplied) |
Screen emissivity correction | Have, with 10 kinds of commonly used material emissivity listing + value adjustment between 0.01 and 1.00 |
The palette | |
The standard palette | 6 |
General technical indicators | |
Color alarm | There is no |
Infrared wavelengths | ~ 8 to 14 microns |
Working temperature | - 10 ° C to 50 ° C (14 ° F to 122 ° F) |
Storage temperature | - 20 ° C to 50 ° C (4 ° F to 122 ° F), without the battery |
Relative humidity | Between 10% and 95% with no condensation |
Point temperature | Center (fixed) |
User definable point mark | Have, 3 user adjustable temperature point mark.Position is adjustable.Screen shows the marked temperature.Users can choose to mark the opening/closing. |
User defined measuring box | Yes, three user adjustable rectangle.Size and location are adjustable.Screen display rectangle statistics: low temperature, high temperature, average temperature.Users can choose to mark the opening/closing. |
Hard portable box | Solid hard portable box with soft package, including adjustable hand belt |
Safety standards | IEC 61010-1: pollution level 2 |
Electromagnetic compatibility | IEC 61326-1: portable electromagnetic environment;IEC 61326-2-2 CISPR 11: group 1, class A |
Australia RCM | RCM IEC 61326-1 |
US the FCC | Section C of article 47 CFR child 15, 15.209, 15.249, 15.207 |
vibration | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
impact | 30 g, 11 ms, IEC 60068-2-27 |
drop | May withstand the 2 m drop impact |
Size (height x width x length) | (about 26.7 cm x 10.1 cm x 14.5 cm) (about 10.5 in x 4.0 in x 5.7 in) |
Weight (including battery) | 2.27 kg or less (5 lb) |
Shell protection grade | IP54 |
Warranty period | Two years (standard) |
Recommended by the calibration cycle | Two years (assuming a normal operation and aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish |
In line with the RoHS directive | There are |
Mode雷竞技appls: Fluke TiS55 + thermal infrared imager
Include:
- Thermal imager
- The ac power (with general ac adapter)
- A piece of lithium ion smart battery
- USB cable
- 4 GB micro SD card
- With flexible transport bags and adjustable hand with strong hard portable box
- Provide雷竞技app free download: Fluke Connect ™ software and user manual
Include:
- Thermal imager
- The ac power (with general ac adapter)
- A piece of lithium ion smart battery
- USB cable
- 4 GB micro SD card
- With soft bag and adjustable hand with solid hard portable box
- Provide雷竞技app free download: Fluke Connect ™ software and user manual