China

雷竞技appFluke - 190-204 ScopeMeter ® color digital oscillographic table

  • 雷竞技appFluke 190-204 ScopeMeter ® Test Tool
  • 雷竞技appFluke 190-204 ScopeMeter ® Test Tool
  • 雷竞技appFluke 190-204 ScopeMeter ® Test Tool
  • 雷竞技appFluke 190-204 ScopeMeter ® Test Tool

The main features

Use double channels雷竞技app and four CAT level IV Fluke ScopeMeter 190 series II for more information, solve more problems.

雷竞技appFluke ScopeMeter 190 series II will be safe level and strong portability combined with desktop oscillographic table of high performance.These rugged ScopeMeter test tools specially designed for plant maintenance engineers and technicians, can under the condition of hard, dirty, dangerous industrial work, test from microelectronics to all devices in the field of power electronics applications.

190 series II is an easy to use test tools, you can use it to handle any troubleshooting tasks.Which include multimeter, TrendPlot ™ and ScopeRecord ™ scroll mode of paperless recorder and Connect with - and - View ™ triggered a hands-free operation, there are more features:

  • Two or four electrical isolation input
  • Security level for 1000 v / 600 v IV CAT CAT III
  • 60 MHz, 100 MHz, 200 MHz or 500 MHz bandwidth models to choose from
  • Sampling rate is high, up to 5 GS/s, resolution up to 200 ps (depending on the use of models and channel)
  • Waveform capture each channel depth storage: 10000 times, so you can magnify the view details
  • Dual channel models dedicated 5000 count digital multimeter
  • Model through four channels of oscillographic table BNC input four instrument measurement
  • Connect - and - View ™ continuous automatic trigger, a single shot, pulse width and video trigger
  • ScopeRecord scroll mode, capture the waveform sampling data up to 48 hours
  • TrendPlot, trend readings for 22 days
  • The advanced automatic measurement, power (Vpwm, VA, W, PF) and time (mAs, V/s and W/s)
  • 51, dustproof and waterproof level for IP can be used in harsh environment
  • Isolated storage devices and PC USB port can be connected
  • Lithium ion battery support longer running time interval:
    • 190 - X04, four channel model for 7 hours (standard BP291)
    • 190 - X02, dual channel model for 4 hours (standard BP290) or for up to 8 hours (using the option BP291)
    • Using an optional external battery charger EBC290 for spare batteries
  • Easy to open the battery cover so you can easily replace the battery
  • When unattended, available standard Kensington or ® as fixed lock and lock oscillographic table convenient slot

Produc雷竞技appts overview: Fluke - 190-204 ScopeMeter ® color digital oscillographic table

Suggestions to the fluke official flagship store of purchase

雷竞技appFluke 190 series II ScopeMeter ® handheld oscillographic table - ScopeMeter ® test tools more than 20 years of innovation.

As a safe level of 1000 v / 600 v IV CAT CAT III dou雷竞技appble channels and four portable oscillographic table, Fluke 190 series II ScopeMeter ® oscillographic table will level of performance, durability and portability.You can choose to 60 MHz, 100 MHz, 200 MHz or 500 MHz bandwidth model, real-time sampling rate is as high as 5 GS/s, a resolution of 200 ps, each channel deep memory can store 10000 samples, which can realize high precision capture and display waveform details, noise and other distractions.

All the model achieves IP - 51 grade can be dustproof, waterproof, moistureproof and resistance to a wide range of temperature change.

Three phase or at a multiloop industrial system on the timing or amplitude measurement, or in the circuit under test to compare and contrast more test points.Such as TrendPlot ™, ScopeRecord ™ and Connect - and - View ™ feature helps you to quickly diagnose industrial machinery, such as automation and process control devices and power electronic devices, thereby reducing maintenance costs and downtime as much as possible.These features make the oscillographic sheet is easy to use, especially in the diagnosis of intractable problems, such as complex waveform, induction, intermittent events and fluctuations, or noise drift problem.

New type of lithium battery technology can ensure you the oscillographic table available throughout the day.

Three - dimensional Testing for Industrial Systems

Try out four channel what can you do?»


Many measures, at the same time in order to find out the root cause of the complex debugging problems.

Easily in the diagnosis of multiple signals of questions about the timing

  • At the same time and check multiple related signal in real time
  • Measuring input and output signals, safety interlock system and feedback loop

Find the problems in the industrial system, including:

  • Circuit voltage/current overload
  • Attenuation/input impedance mismatch
  • Load fluctuations/drift
  • Regulating circuit signal integrity
  • The key signal validation test points
  • Input/output/feedback on a matter of time
  • Induction noise and interference
  • Random closing and reset
Three - phase Testing for Diagnosing the Vsd, Power Inverters, and Converters

Diagnosis of VSDs * or power inverter and converter »

  • In the three-phase power input harmonic, transient, and load
  • The control circuit of the troubleshooting of dc to ac converter or output level IGBT grid fault
  • Cable interface - test reflection and transient PWM output
  • Accurately measure the rise time of pulse edge IGBT, reflection amplitude and peak
  • Vpwm measurement, drive on the output of the effective voltage measurement
Safely Measure from the mV to kV

In mV to kV within the scope of security measure

The insulation of the independent input enables you to mix with different ground reference circuit measurement, which reduces the risk of accidental short circuit.Traditional desktop oscillographic table has not been equipped with a differential probe and insulation transformer, can only reference line power grounding measurements.With the aid of the wide range of applications (from the mV to kV) standard probe, you can deal with from the microelectronics field to any problems with the heavy high voltage electrical applications.

Can be used in harsh environment protection class IP - 51

ScopeMeter ® handheld oscillographic table durable and vibration control, is suitable for use in dirty and dangerous environment.Equipped with a sealed enclosure, dustproof, waterproof, moistureproof, and against air pollution.Each use ScopeMeter ® handheld oscillographic table, you can be at ease use, it can reliably solve any problem for you.
Built in Digital Multimeter to Quickly and Conveniently Perform Precise Measurements

The built-in digital multimeter

Use the built-in digital multimeter 5000 count waveform analysis allows you to easily convert multimeter measurement precision.Measurement functions including Vdc, Vac, Vac + dc, resistance, connectivity and diode testing.To have wide conversion factor right shunt, probe or adapter to measure current and temperature.
The Work a Full Shift on a Single Charge

Portability is good

New advanced lithium-ion battery technology, the battery can work continuously for seven hours.Easy to open the battery cover allows you to quickly replace the battery.
The Capture and Share Waveforms Easily with the New USB Connectivity

USB connection to capture and share the waveform.

New雷竞技app Fluke 190 series II provides two USB ports, and with the input circuit insulation measurement.It is convenient for data transmission to the PC.Waveform can be recorded, and Shared with original equipment manufacturers, colleagues and support staff waveform.Can set the waveform, screen capture content and instrument saved to the USB storage devices.ScopeMeter ® test tools can be stored as CSV format, the format of the file can be transferred to U disk.This file format can be used for 雷竞技appfurther processing data in Excel ®, can also be FlukeView ® in for a more detailed analysis of waveform.
See a Stable Display Instantly with the Connect - and - View ™ Triggering

Connect - and - View ™ trigger can be instantaneous and stable display

If you ever use other oscillographic table, you will understand how tricky trigger.If the setting is not correct, the results may not be stable or not correct.
Connect - and - View ™ by identifying the signal types to automatically set the right trigger.Without contact button, you can get all the signal is stable, reliable, repeat display, including the motor drive and control signals.When you fast, continuously measuring a series of test points, this feature is especially fast and convenient.
Record Up to 48 Hours of High - Resolution Waveforms with ScopeRecord ™

ScopeRecord ™ mode can be realized for up to 48 hours of high resolution waveform record

ScopeRecord ™ memory can be stored up to 30000 or more on each channel most stronghold, and capture at a speed of 8 ns rapid intermittent events and fault.(two set of multi-channel records can be stored for analysis purposes.)
  • Dynamic files and record events, such as UPS, power supply or motor cycle.
  • By keeping trigger mode, ScopeMeter ® test tool can automatically identify power failure and storage before the waveform data.
Record up to 22 Days with Trendplot ™ Paperless Recorder to Find Intermittent Faults

TrendPlot ™ paperless recorder to record for 22 days, can help you find the intermittent failures.

Occasional failure is harder to find.These intermittent failures may be by improper connection, dust, dirt, corrosion, bolt joint or damaged the cause.Lines, depression, or motor start and stop could lead to a stop.When that happens, 雷竞技appyou may not be near, but FlukeScopeMeter ® test tool will help you to monitor at any time.
  • Smallest peak for 22 days and the maximum peak and average
  • Show all the input voltage, current, temperature, frequency and phase, all these items are marked with the time and date, in order to find out the fault

Produc雷竞技appt specifications: Fluke - 190-204 ScopeMeter ® color digital oscillographic table

Technical indicators

bandwidth 雷竞技appFluke 190-504:500 MHz
雷竞技appFluke 190-502:500 MHz
雷竞技appFluke 190-204:200 MHz
雷竞技appFluke 190-202:200 MHz
雷竞技appFluke 190-104:100 MHz
雷竞技appFluke 190-102:100 MHz
雷竞技appFluke 190-062:60 MHz
The channel number 雷竞技appFluke. 190-504:500 MHz: 4 channels
雷竞技appFluke 190-502:500 MHz: 2 channels
雷竞技appFluke. 190-204:200 MHz: 4 channels
雷竞技appFluke 190-202:200 MHz: 2 channels
雷竞技appFluke 190-104:100 MHz: 4 channels
雷竞技appFluke 190-102:100 MHz: 2 channels
雷竞技appFluke 190-062:60 MHz: 2 channels
Real-time sampling rate 雷竞技appFluke 190-504:5 GS/s
雷竞技appFluke 190-502:5 gs/s
雷竞技appFluke 190-204:2.5 GS/s
雷竞技appFluke 190-202:2.5 GS/s
雷竞技appFluke 190-104:1.25 GS/s
雷竞技appFluke 190-102:1.25 GS/s
雷竞技appFluke 190-062:625 MS/s
The input 雷竞技appFluke 190 - X04:4 x BNC input for oscillographic table and multimeter measurement
雷竞技appFluke 190 - X02:2 BNC input and 1 DMM input
Independent floating input isolation Up to 1000 V between the input, reference and grounding CAT CAT III / 600 V IV
Time base scope Ns/div 1 to 4 s/div (190-504500 MHz model)
Ns/div 2 to 4 s/div (190-20 x, 200 MHz model)
5 ns/div to 4 s/div (190-10 x, 100 MHz model)
10 ns/div to 4 s/div (190-062, 60 MHz model)
The input sensitivity 2 mV - 100 - V/div and attenuation
Trigger type Connect - and - View ™, free operation, a single photo, edge, latency, dual slope, college video, video circuit, pulse width is optional, N cycle
Trigger source 雷竞技appFluke 190 - X02:2 BNC input or by DMM external input connection
雷竞技appFluke 190 - X04:Four BNC input
Electronic pulse capture 8 ns
Oscillographic table measurement The cursor7:
Automatically:30
Record the length of the largest ScopeRecord mode: every time input 30000 pt
Oscillographic table schema: every time input 10000 pt
reserved Digital afterglow provides the oscillographic table similar to the simulation of wave attenuation
Waveform comparison With automatic pass/fail test waveform reference

DMM specifications (type of dual channel)

The instrument input
(also used as the oscillographic table schema external trigger input)
4 mm banana plug input and oscillographic table input and grounding is completely isolated
Maximum resolution 5000 count
measurement Vdc, Vac RMS, Vac + dc RMS, resistance, persistent, diode test, current (by current clamp or shunt), temperature of DHS in C or DHS F (using the optional converter)
Storage location Screen + set: 30 store waveform, 10 9 record and store a copy of the screen.
display 153 mm quick update of full color LCD

Environmental indicators

Working temperature 0 DHS C to 40 DHS C (including battery)
0 to 50 DHS DHS C C (including battery)
Storage temperature - 20 ° C to + 60 ° C
Work at an altitude of The CAT IV III 1000 V, 600 V/CAT up to 2000 m (6666 ft)
600 V / 1000 V II CAT CAT III up to 3000 m (10000 ft)

Safety specifications

Electrical safety The CAT CAT III 1000 V / 600 V IV (EN61010-1)

The mechanical and general specifications

size 270 x 190 x 70 mm
The weight of the 2.2 kg
Warranty period The host three years warranty
Lithium ion batteries 雷竞技appFluke 190 - XX2:BP290 (2400 mah)
雷竞技appFluke 190 - XX4:BP291 (4800 mah)

Mode雷竞技appls: Fluke - 190-204 ScopeMeter ® color digital oscillographic table

雷竞技appFluke. 190-204
ScopeMeter color digital oscilloscope, 200 MHz, 4 channel DMM/external input
  • Color ScopeMeter, 200 MHZ
  • Four channels
  • DMM/Ext input

Manual + 雷竞技appresources: Fluke - 190-204 ScopeMeter ® color digital oscillographic table