雷竞技appFluke 1508 IND insulation resistance tester (digital "shake table")
The main features
- The insulation of the 0.01 M Ω to 10 G Ω test
- Remote testing probe, repetitive or difficult to reach by measuring point of testing is more convenient
- Insulation test voltage: 50 V, 100 V, 250 V, 500 V and 1000 V, suitable for a variety of applications
- Pass/fail () function, make the repeatability test is simple and convenient
- Save/call function, with 19 storage unit, to save time and manpower
- Ac/dc voltage: 0.1 V to 600 V
- Ω Ω resistance: 0.01 to 20.00 K
- Automatic shutdown function, to save battery power
- CAT IV 600 V measurement security levels, improve the ability of the protection of personnel
- Including attachments: test line, test probes, remote control pens and, alligator clip
- 5 years warranty
Produc雷竞技appts overview: Fluke 1508 IND insulation resistance tester (digital "shake table")
雷竞技appFluke 1508 IND
1508 IND insulation resistance tester is designed for the industrial enterprise users to tailor, in the original precision, durable, safe and easy to use to upgrade again, the stronghold of the warranty period will be extended to five years, upgraded and will test the attachment, more large alligator clip group can measure the target scene.
Produc雷竞技appt specifications: Fluke 1508 IND insulation resistance tester (digital "shake table")
Produ雷竞技appct specifications: Fluke 1508 IND insulation resistance tester (digital "shake table")
Ac/dc voltage measurement | ||
precision | The scope of | 600.0 V |
The resolution of the | 0.1 V | |
50 Hz - 400 Hz + + digital reading (%) | Plus or minus 2% (+ 3) | |
The input impedance | 3 M Ω (nominal value), < 100 pF | |
Common mode rejection ratio (1 k Ω imbalance) | > 60 dB, when the dc, 50 or 60 Hz | |
Overload protection | Valid values or dc 600 V | |
The ground resistance measurement | ||
Range/resolution | 20.00 Ω | 0.01 Ω |
200.0 Ω | 0.1 Ω | |
2000 Ω | 1 Ω | |
20.00 k Ω | 0.01 k Ω | |
precision | Plus or minus 1.5% (+ 3) | |
Overload protection | 2 V RMS or dc | |
Open circuit voltage | > 4.0 V, < 8 V | |
Short circuit current | > 200.0 mA | |
Insulation technical indicators | ||
Measuring range | 0.01 M Ω Ω to 10 G | |
The test voltage | 50 V, 100 V, 250 V, 500 V, 1000 V | |
The test voltage accuracy | + 20% and - 0% | |
Short circuit test current | 1 mA, nominal value | |
Automatic discharge | When C = 1 (including F or more hours, discharge time < 0.5 s | |
Electric circuit detection function | Before test initialization, if a greater than 30 V voltage is detected, the test is prohibited. | |
The maximum load capacity | In as much as 1 (including F under the load of work. | |
General technical parameters | ||
The maximum voltage applied to an arbitrary terminals | 600 V ac RMS or dc | |
Storage temperature | - 40 ° to 60 ° C - C (to 40 ° F to 140 ° F) | |
Working temperature | - 20 ° C to 55 ° C (4 ° F to 131 ° F) | |
The temperature coefficient of | Accuracy of 0.05 x (given) / ° C, 28 ° C temperature 18 ° C < or > (< > 64 ° F or 82 ° F) | |
Relative humidity | 0% to 95%, 10 ° to 30 ° C C (50 ° F to 86 ° F) | |
0% to 75%, 30 ° C to 40 ° C (86 ° F to 104 ° F) | ||
0% to 40%, and 40 ° C to 55 ° C (104 ° F to 131 ° F) | ||
Vibration resistance | Random, 2 g, 5-500 Hz, accord with MIL - PRF - 28800 - f, the requirements of Class 2 instrument | |
Impact resistance | 1 m drop, conform to the IEC 61010-1 version 2 (1 m drop test, 6 surface, oak floor) | |
Electromagnetic compatibility | In the 3 V/M of RF field, the accuracy of = the given accuracy (EN 61326-97) took | |
security | Meet the ANSI/ISA 82.02.01 (2004, 61010-1) CAN/CSA - C22.2 No. 1010.1 and IEC/EN 61010-1 version 2 requirements for CAT 600 V IV equipment | |
certification | CSA, accord with a standard CSA/C22.2 No. 1010.1;TUV, conform to the standard IEC/EN 61010-1 version 2 | |
The battery | 4 AA size batteries (15 a or IEC LR6 (NEDA) | |
Battery life | Used for insulation test: | At room temperature for at least 1000 times with new batteries insulation test.Test: refers to the standard 1000 V, to 1 M Ω, duty cycle open for 5 seconds, 25 seconds to shut down. |
When the resistance measurement: | Using new batteries at room temperature for at least 2500 times grounding resistance measurement.Refers to the standard testing: 1 Ω, duty cycle open for 5 seconds, 25 seconds to shut down | |
size | High 5.0 cm x 10.0 cm wide by 20.3 cm (1.97 in x 3.94 in x 8.00 in long wide high) | |
The weight of the | 550 g (1.2 lb) | |
The IP rating | IP40 | |
The altitude | work | 2000 m CAT IV 600 V, 3000 m CAT III 600 V |
Non-working (store) | 12000 m | |
Overload capacity | 110% of |
Mode雷竞技appl: Fluke 1508 IND insulation resistance tester (digital "shake table")
雷竞技appFluke 1508 IND
contains
- 雷竞技appFluke 1508 insulation resistance tester host
- TLL224 test line
- TP74 test probe
- TP165X pens and control
- Large alligator clip
- The user manual