China

雷竞技appFluke 1623-2 KIT grounding resistance tester

  • 雷竞技appFluke 1623-2 GEO Earth Ground Tester Kit
  • 雷竞技appFluke 1623-2 GEO Earth Ground Tester
  • 雷竞技appFluke 1623-2 GEO Earth Ground Tester
  • 雷竞技appFluke 1623-2 GEO Earth Ground Tester Kit

The main features

No test of pile

雷竞技appFluke 1623-2 KIT by simply using grounding resistance tester jaw measuring grounding resistance.When using this method of measurement, the two jaw clip on grounding rods, each jaw is connected to the tester.Completely without using grounding pile.One of the fixed voltage clamp taste should be known, another jaw measuring current.Then, the tester will automatically determine the resistance of the ground rod.This test method is only applicable to participants in the buildings or structures with the situation of the grounding system, but in most cases.If the earth is only a path, such as many residential applications, used by the no pile test method cannot provide acceptable values, you must use the potential drop test method.

Adopting pile test, without having to disconnect grounding rods - keep the combination of system on the integrity of the test.Now no need to spend time for the system and the connection of grounding rods placed on pile, it can save a lot of time.Before something you never thought about location, you can also perform ground testing, including building, cable tower, or anything you unable to gain access to the location of the land.

Fully functional tester

雷竞技appKIT is a Fluke 1623-2 different grounding tester, can complete all four types of grounding measurements.

  • Three pole and quadrupole potential drop pile (to use)
  • Quadrupole soil resistivity test pile (to use)
  • Selective test (using the pile and a jaw)
  • No pile test (using only two jaw)

Produc雷竞技appts overview: Fluke 1623-2 KIT grounding resistance tester

Suggestions to the fluke official flagship store of purchase

雷竞技appFluke 1623-2 KIT grounding resistance tester can through the USB port storage and download the data.First-class accessories can help to simplify and speed up the test of time.

  • Three pole and quadrupole potential drop ground resistance circuit test
  • Quadrupole soil resistivity test
  • Using a jaw for selective grounding rods testing
  • Using two jaw of pile ground rod test
  • IP56 protection grade meet the outdoor use
  • Hard carry case
  • USB data storage and transmission

Moreover, the tester is easy to use.Each test, the tester will prompt you to use for to pile or jaw;Large size rotary switch to make sure that you even wearing gloves can operate.

Produc雷竞技appt specifications: Fluke 1623-2 KIT grounding resistance tester

General technical indicators
Display: 1999 liquid crystal display (LCD) The use of special symbols, according to digital 25 mm high, fluorescent light
The user interface Through the TURN (rotate) and START (START) menu design with instant measurement.The only element operation for rotary switch and START (START) button.
Strong, waterproof, dustproof Instrument is specially designed for harsh environment conditions (rubber protection cover, IP56)
memory Through the USB port access to the internal storage can be up to 1500 records
Temperature range
Working temperature - 10 ° C to 50 ° C (14 ° F to 122 ° F)
Storage temperature 30 ° to 60 ° C - C (22 ° F to 140 ° F) -
The temperature coefficient of Plus or minus 0.1% of reading / ° C < 18 ° C > 28 ° C
Inherent error Please reference temperature range, one year guarantee
The operating error Please refer to working temperature range, one year guarantee
Climate level C1 (IEC 654-1), 5 ° C to + 45 ° C (23 ° to 115 ° F) +, 5% to 95% RH
Protection type According to the EN60529, shell protection grade is IP56;Battery cover protection grade for IP40
security Adopt dual and/or reinforced insulation protection.The largest 50 V.IEC61010-1: pollution level 2
EMC perturbation resistance (radiation) IEC61326-1: portable
The quality system According to DIN ISO 9001 standard development, design and production
External voltage Largest external voltage 24 V (dc and ac < = 400 Hz), ban higher value measurement
The external voltage rejection ratio > 120 dB (162/3, 50, 60, and 400 Hz)
Measuring time Usually for 6 seconds
Maximum overload 250 Vrms (belong to misuse)
Auxiliary power 6 x 1.5 V alkaline batteries (AA LR6)
Battery life span Usually higher than 3000 times
Size (width x height x deep) 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)
The weight of the 1.1 kg (2.43 lb), including the battery
7.6 kg (16.8 lb) (portable box contains attachments and battery)
RA three pole grounding resistance measurement (IEC 1557-5)
Switch gear Ra.Three pole
The resolution of the 0.001 Ω to 10 Ω
Measuring range Ω Ω 0.020 to 19.99 k
precision Plus or minus (reading of 2% + 3 digits)
The operating error Plus or minus (reading of 5% + 3 digits)
The measuring principle, current/voltage measurement
Measure the voltage Vm = 48 V (ac)
Short circuit current > 50 mA
Measure the frequency 128 Hz
The resistance (R probes.) Maximum 100 k Ω
Auxiliary grounding electrode resistance (R)H.) Maximum 100 k Ω
RH.And Rs.The additional error RH.• • • R Ω [k]s./ R Ω [k]a.• • • 0.2% [Ω]
Using the error indicator monitoring Rs.And RH..
Automatic range selection.
If through the current clamp of the current is too low, do not perform measurements.
Ra.Quadrupole grounding resistance measurement (IEC 1557-5)
Switch gear Ra.quadrupole
The resolution of the 0.001 Ω to 10 Ω
Measuring range Ω Ω 0.020 to 19.99 k
precision Plus or minus (reading of 2% + 3 digits)
The operating error Plus or minus (reading of 5% + 3 digits)
The measuring principle, current/voltage measurement
Measure the voltage Vm = 48 V (ac)
Short circuit current > 50 mA
Measure the frequency 128 Hz
The resistance (R probeS +RES) Maximum 100 k Ω
Auxiliary grounding electrode resistance (R)H.) Maximum 100 k Ω
RH.And Rs.The additional error RH.• • • R Ω [k]s./ R Ω [k]a.• • • 0.2% [Ω]
Using the error indicator monitoring Rs.And RH..
Automatic range selection.
Use the current clamp RA three highly selective grounding resistance measurement (Ra.Use the jaw)
Switch gear Ra.Three pole, the use of jaw
The resolution of the 0.001 Ω to 10 Ω
Measuring range Ω Ω 0.020 to 19.99 k
precision Plus or minus (reading of 7% + 3 digits)
The operating error Plus or minus (reading of 10% + 5 digits)
Measuring principle, current/voltage measurement (with an external current clamp)
Measure the voltage Vm = 48 V (ac)
Short circuit current > 50 mA
Measure the frequency 128 Hz
The resistance (R probes.) Maximum 100 k Ω
Auxiliary grounding electrode resistance (R)H.) Maximum 100 k Ω
Using the error indicator monitoring Rs.And RH..
Automatic range selection.
If through the current clamp of the current is too low, do not perform measurements.
Use the current clamp RA quadrupole selective grounding resistance measurement (Ra.Use the jaw)
Switch gear Ra.Quadrupole, the use of jaw
The resolution of the 0.001 Ω to 10 Ω
Measuring range Ω Ω 0.020 to 19.99 k
precision Plus or minus (reading of 7% + 3 digits)
The operating error Plus or minus (reading of 10% + 5 digits)
Measuring principle, current/voltage measurement (with an external current clamp)
Measure the voltage Vm = 48 V (ac)
Short circuit current > 50 mA
Measure the frequency 128 Hz
The resistance (R probes.) Maximum 100 k Ω
Auxiliary grounding electrode resistance (R)H.) Maximum 100 k Ω
Using the error indicator monitoring Rs.And RH..
Automatic range selection.
If through the current clamp of the current is too low, do not perform measurements.
No pile ground loop measurement (2 jaw)
Switch gear Ra.Quadrupole, two of the jaw
The resolution of the 0.001 Ω to 10 Ω
Measuring range Ω Ω 0.020 to 19.99 k
precision Plus or minus (reading of 7% + 3 digits)
The operating error Plus or minus (reading of 10% + 5 digits)
Measuring principle, using two current transformer no piles of closed loop resistance measurement
Measure the voltage Vm = 48 V (ac)
Measure the frequency 128 Hz
Noise current (IEXT) Of the largest IEXT(R = 10 A (communication)a.< 20 Ω)
Of the largest IEXT(R = 2 A (communication)a.> 20 Ω)
Automatic range selection.
Only when to use the recommended for the specified minimum distance measure current clamp, information about no pile ground loop measurement is valid.

Mode雷竞技appl: Fluke 1623-2 KIT grounding resistance tester

雷竞技appFluke 1623-2 suite
雷竞技appFluke 1623-2 GEO Earth Ground Tester Kit

Include:

  • GEO grounding tester
  • The user manual
  • The battery
  • Quick reference guide
  • The USB cable
  • Two jaw
  • C1620 professional carry the box
  • Four grounded pile
  • Three cable