雷竞技appFluke 1623-2 KIT grounding resistance tester
The main features
No test of pile
雷竞技appFluke 1623-2 KIT by simply using grounding resistance tester jaw measuring grounding resistance.When using this method of measurement, the two jaw clip on grounding rods, each jaw is connected to the tester.Completely without using grounding pile.One of the fixed voltage clamp taste should be known, another jaw measuring current.Then, the tester will automatically determine the resistance of the ground rod.This test method is only applicable to participants in the buildings or structures with the situation of the grounding system, but in most cases.If the earth is only a path, such as many residential applications, used by the no pile test method cannot provide acceptable values, you must use the potential drop test method.
Adopting pile test, without having to disconnect grounding rods - keep the combination of system on the integrity of the test.Now no need to spend time for the system and the connection of grounding rods placed on pile, it can save a lot of time.Before something you never thought about location, you can also perform ground testing, including building, cable tower, or anything you unable to gain access to the location of the land.
Fully functional tester
雷竞技appKIT is a Fluke 1623-2 different grounding tester, can complete all four types of grounding measurements.
- Three pole and quadrupole potential drop pile (to use)
- Quadrupole soil resistivity test pile (to use)
- Selective test (using the pile and a jaw)
- No pile test (using only two jaw)
Produc雷竞技appts overview: Fluke 1623-2 KIT grounding resistance tester
雷竞技appFluke 1623-2 KIT grounding resistance tester can through the USB port storage and download the data.First-class accessories can help to simplify and speed up the test of time.
- Three pole and quadrupole potential drop ground resistance circuit test
- Quadrupole soil resistivity test
- Using a jaw for selective grounding rods testing
- Using two jaw of pile ground rod test
- IP56 protection grade meet the outdoor use
- Hard carry case
- USB data storage and transmission
Moreover, the tester is easy to use.Each test, the tester will prompt you to use for to pile or jaw;Large size rotary switch to make sure that you even wearing gloves can operate.
Produc雷竞技appt specifications: Fluke 1623-2 KIT grounding resistance tester
General technical indicators | |
Display: 1999 liquid crystal display (LCD) | The use of special symbols, according to digital 25 mm high, fluorescent light |
The user interface | Through the TURN (rotate) and START (START) menu design with instant measurement.The only element operation for rotary switch and START (START) button. |
Strong, waterproof, dustproof | Instrument is specially designed for harsh environment conditions (rubber protection cover, IP56) |
memory | Through the USB port access to the internal storage can be up to 1500 records |
Temperature range | |
Working temperature | - 10 ° C to 50 ° C (14 ° F to 122 ° F) |
Storage temperature | 30 ° to 60 ° C - C (22 ° F to 140 ° F) - |
The temperature coefficient of | Plus or minus 0.1% of reading / ° C < 18 ° C > 28 ° C |
Inherent error | Please reference temperature range, one year guarantee |
The operating error | Please refer to working temperature range, one year guarantee |
Climate level | C1 (IEC 654-1), 5 ° C to + 45 ° C (23 ° to 115 ° F) +, 5% to 95% RH |
Protection type | According to the EN60529, shell protection grade is IP56;Battery cover protection grade for IP40 |
security | Adopt dual and/or reinforced insulation protection.The largest 50 V.IEC61010-1: pollution level 2 |
EMC perturbation resistance (radiation) | IEC61326-1: portable |
The quality system | According to DIN ISO 9001 standard development, design and production |
External voltage | Largest external voltage 24 V (dc and ac < = 400 Hz), ban higher value measurement |
The external voltage rejection ratio | > 120 dB (162/3, 50, 60, and 400 Hz) |
Measuring time | Usually for 6 seconds |
Maximum overload | 250 Vrms (belong to misuse) |
Auxiliary power | 6 x 1.5 V alkaline batteries (AA LR6) |
Battery life span | Usually higher than 3000 times |
Size (width x height x deep) | 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in) |
The weight of the | 1.1 kg (2.43 lb), including the battery 7.6 kg (16.8 lb) (portable box contains attachments and battery) |
RA three pole grounding resistance measurement (IEC 1557-5) | |
Switch gear | Ra.Three pole |
The resolution of the | 0.001 Ω to 10 Ω |
Measuring range | Ω Ω 0.020 to 19.99 k |
precision | Plus or minus (reading of 2% + 3 digits) |
The operating error | Plus or minus (reading of 5% + 3 digits) |
The measuring principle, current/voltage measurement | |
Measure the voltage | Vm = 48 V (ac) |
Short circuit current | > 50 mA |
Measure the frequency | 128 Hz |
The resistance (R probes.) | Maximum 100 k Ω |
Auxiliary grounding electrode resistance (R)H.) | Maximum 100 k Ω |
RH.And Rs.The additional error | RH.• • • R Ω [k]s./ R Ω [k]a.• • • 0.2% [Ω] |
Using the error indicator monitoring Rs.And RH.. Automatic range selection. If through the current clamp of the current is too low, do not perform measurements. |
|
Ra.Quadrupole grounding resistance measurement (IEC 1557-5) | |
Switch gear | Ra.quadrupole |
The resolution of the | 0.001 Ω to 10 Ω |
Measuring range | Ω Ω 0.020 to 19.99 k |
precision | Plus or minus (reading of 2% + 3 digits) |
The operating error | Plus or minus (reading of 5% + 3 digits) |
The measuring principle, current/voltage measurement | |
Measure the voltage | Vm = 48 V (ac) |
Short circuit current | > 50 mA |
Measure the frequency | 128 Hz |
The resistance (R probeS +RES) | Maximum 100 k Ω |
Auxiliary grounding electrode resistance (R)H.) | Maximum 100 k Ω |
RH.And Rs.The additional error | RH.• • • R Ω [k]s./ R Ω [k]a.• • • 0.2% [Ω] |
Using the error indicator monitoring Rs.And RH.. Automatic range selection. |
|
Use the current clamp RA three highly selective grounding resistance measurement (Ra.Use the jaw) | |
Switch gear | Ra.Three pole, the use of jaw |
The resolution of the | 0.001 Ω to 10 Ω |
Measuring range | Ω Ω 0.020 to 19.99 k |
precision | Plus or minus (reading of 7% + 3 digits) |
The operating error | Plus or minus (reading of 10% + 5 digits) |
Measuring principle, current/voltage measurement (with an external current clamp) | |
Measure the voltage | Vm = 48 V (ac) |
Short circuit current | > 50 mA |
Measure the frequency | 128 Hz |
The resistance (R probes.) | Maximum 100 k Ω |
Auxiliary grounding electrode resistance (R)H.) | Maximum 100 k Ω |
Using the error indicator monitoring Rs.And RH.. Automatic range selection. If through the current clamp of the current is too low, do not perform measurements. |
|
Use the current clamp RA quadrupole selective grounding resistance measurement (Ra.Use the jaw) | |
Switch gear | Ra.Quadrupole, the use of jaw |
The resolution of the | 0.001 Ω to 10 Ω |
Measuring range | Ω Ω 0.020 to 19.99 k |
precision | Plus or minus (reading of 7% + 3 digits) |
The operating error | Plus or minus (reading of 10% + 5 digits) |
Measuring principle, current/voltage measurement (with an external current clamp) | |
Measure the voltage | Vm = 48 V (ac) |
Short circuit current | > 50 mA |
Measure the frequency | 128 Hz |
The resistance (R probes.) | Maximum 100 k Ω |
Auxiliary grounding electrode resistance (R)H.) | Maximum 100 k Ω |
Using the error indicator monitoring Rs.And RH.. Automatic range selection. If through the current clamp of the current is too low, do not perform measurements. |
|
No pile ground loop measurement (2 jaw) | |
Switch gear | Ra.Quadrupole, two of the jaw |
The resolution of the | 0.001 Ω to 10 Ω |
Measuring range | Ω Ω 0.020 to 19.99 k |
precision | Plus or minus (reading of 7% + 3 digits) |
The operating error | Plus or minus (reading of 10% + 5 digits) |
Measuring principle, using two current transformer no piles of closed loop resistance measurement | |
Measure the voltage | Vm = 48 V (ac) |
Measure the frequency | 128 Hz |
Noise current (IEXT) | Of the largest IEXT(R = 10 A (communication)a.< 20 Ω) |
Of the largest IEXT(R = 2 A (communication)a.> 20 Ω) | |
Automatic range selection. Only when to use the recommended for the specified minimum distance measure current clamp, information about no pile ground loop measurement is valid. |
Mode雷竞技appl: Fluke 1623-2 KIT grounding resistance tester
Include:
- GEO grounding tester
- The user manual
- The battery
- Quick reference guide
- The USB cable
- Two jaw
- C1620 professional carry the box
- Four grounded pile
- Three cable