雷竞技appFluke 1630-2 FC earth loop resistance test clamp table
The main features
- For fast and safely test indoor/outdoor ground loop resistance, support the use of no auxiliary measuring method
- Ac leakage current measurements: constantly open grounding system grounding rods, can measure ac leakage
- Durable: in the scene of bad environment, heavy jaw still can keep the precision and durable
- Record measurements: save up to 32760 measurements in the memory
Produc雷竞技appts overview: Fluke 1630-2 FC earth loop resistance test clamp table
Grounding resistance test is located in the narrow space inside the equipment (including indoor or do not allow the use of auxiliary grounding area).Keep online - identify grounding resistance, without interruption from the system after opening grounding connection again.
雷竞技appFluke 1630-2 FC ground loop resistance test clamp table with a Fluke tools consistent high quality and durability.Durable clamp table jaw even in the daily operation of the industrial environment can guarantee accurate and durable.
No auxiliary measuring method
1630-2 FC clamp table more than double jaw is used to measure the grounding resistance of grounding system., you don't have to perform dangerous using the test technology and time-consuming to disconnect and connect the ground loop operation, also don't have to find the suitable location to install auxiliary grounding for testing.You can also difficult position before the execution of the grounding test: building interior, cable tower or unable to contact the soil in place of any auxiliary grounding position.
雷竞技appFluke Connect®Wireless systems
1630-2 FC sup雷竞技appport Fluke Connect wireless system (not in all regions are provided).雷竞技appFluke Connect using the application on the smart phone or tablet wirelessly connected clamp table.The application can be on your smartphone or tablet screen earthing resistance measurements.You can use these measurements雷竞技app, GPS location from your phone and images stored in a Fluke Connect Cloud storage, and share them with your team.
Produc雷竞技appt specifications: Fluke 1630-2 FC earth loop resistance test clamp table
Electrical technical indicators | ||
The largest ground voltage | 1000 V | |
The battery type | AA alkaline IEC/EN LR6 (x4) | |
Battery life | * for more than 15 hours | |
* in grounding resistance measurement mode, the back light and radio frequency mode off | ||
Frequency range | 40 Hz to 1 kHz | |
Protection grade | IEC/EN 60529: IP30 (jaw closed) | |
LCD display | The digital reading | 9999 count |
The refresh rate | 4 / SEC. | |
Working temperature | - 10 ° C to + 50 ° C | |
Storage temperature | - 20 ° C to + 60 ° C | |
Working humidity | The condensation (< 10 ° C) (< 50 ° F) | |
90% RH or less (10 ° to 30 ° C C / 50 ° F to 86 ° F) | ||
75% RH or less (30 ° C to 40 ° C / 86 ° F to 104 ° F) | ||
45% RH or less (40 ° C to 50 ° C / 104 ° F to 122 ° F) | ||
(condensate) | ||
Work at an altitude of | 2000 m (6561 ft) | |
For altitude | 12, 000 m (39370 ft) | |
Reference temperature | 23 ° C + / - 5 ° C (73 ° F + 9 ° F) for | |
The temperature coefficient of | 0.15% (x) specified precision / ° C (18 ° C or > < 28 ° C [< 64.4 ° F or > 82.4 ° F]) | |
Overload indicator | OL | |
Data record capacity | A minimum of 32760 measurements | |
Data record time interval | 1 second to 59 minutes and 59 seconds | |
According to the standard loop resistance reading specifications | ||
Input (Ω) | The minimum | The biggest |
0.474 | 0.417 | 0.531 |
0.5 | 0.443 | 0.558 |
10 "=" | 9.55 | 10.45 |
= "100" | = "96" | = "104" |
security | ||
general | IEC/EN 61010-1 level pollution IEC/EN 61557-1 | |
measurement | IEC/EN 61010-2-032: the CAT III 1000 V, 600 V/CAT IV | |
Current clamp table for leakage current measurement | IEC/EN 61557 - lift, 30 A/m or less | |
Grounding resistance | IEC/EN 61557-5 | |
The effectiveness of the protective measures | IEC/EN 61557-16 | |
Electromagnetic compatibility (EMC) | The international standard | IEC/EN 61326-1: portable electromagnetic environment |
CISPR group B class, therefore the IEC/EN 61326-2-2 | ||
South Korea's (KCC) | Class A equipment (industrial radio and communication equipment) | |
The United States (FCC) | 47 CFR part 15 B child.According to the provisions of article 15.103 of this product is regarded as tax-free equipment | |
radio | ||
Frequency range | 2412 MHz to 2462 MHz | |
The output power | The < 10 mW | |
Radio frequency certification | The FCC ID: T68 - FBLE IC: 6627 a - FBLE | |
General technical indicators | ||
Conductor size | About 40 mm (1.57 in) | |
Size (length x width x height) | 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in) | |
The weight of the | 880 g (31 oz) | |
Warranty period | 1 year | |
Ground loop resistance | ||
range | precision= "1"Plus or minus (+ / - % + Ω reading value) | |
0.025 Ω to Ω 0.249 | 1.5% + 0.02 Ω | |
0.250 Ω to Ω 0.999 | 1.5% + 0.05 Ω | |
1.000 Ω to Ω 9.999 | 1.5% + 0.10 Ω | |
10.00 Ω to Ω 49.99 | 1.5% + 0.30 Ω | |
50.00 Ω to Ω 99.99 | 1.5% + 0.50 Ω | |
100.0 Ω to Ω 199.9 | 3.0% + 1.0 Ω | |
200.0 Ω to Ω 399.9 | 5.0% + 5.0 Ω | |
400 Ω Ω to 599 | 10.0% + 10 Ω | |
600 Ω Ω to 1500 | 20.00% | |
= "1"Loop resistance, inductance, center conductors and jaw with vertical | ||
After mA floor drain current measurements | ||
Automatic range 50/60 Hz, true RMS, wave coefficient CF 3 or less | ||
range | The resolution of the | precision= "1"Plus or minus (+ / - % reading value + mA) |
0.200 mA to 3.999 mA | 1 mu A | 2.0% + 0.05 mA |
4.00 mA to 39.99 mA | 10 mu A | 2.0% + 0.03 mA |
40.0 mA to 399.9 mA | 100 mu A | 2.0% + 0.3 mA |
0.400 A and 3.999 A | 1 mA | 2.0% + 3 mA |
4.00 A and 39.99 A | 10 mA, | 2.0% + 30 mA |
= "1"Apply to the signal frequency
|
Mode雷竞技appl: Fluke 1630-2 FC earth loop resistance test clamp table
- 1630-2 FC earth loop resistance test clamp table
- Hard suitcases
- Standard calibration loop resistance plate
- 4 AA batteries
- Safety information guide and quick reference guide