China

雷竞技app17 b + IND Fluke digital multimeter

  • 雷竞技app17 b + IND 1500 x1000 01 Fluke
  • 雷竞技app17 b + IND 1500 x1000 02 Fluke
  • 雷竞技app17 b + IND 1500 x1000 03 Fluke

The main features

  • 600 V CAT III safety design index
  • Voltage to upgrade to 6000 words
  • Capacitance range increased to 2000 mu F
  • The frequency and temperature measurement
  • Voltage, resistance, current, capacitance measurement
  • Increasing magnetic hanging belt, make the operation more convenient
  • Five years warranty

Produc雷竞技appts overview: Fluke 17 b + IND digital multimeter

雷竞技appFluke 17 b + IND

Digital multimeter designed for industrial enterprise users to tailor, in the original precision, durable, safe and easy to use to upgrade again, the stronghold of voltage to upgrade to 6000 words, according to the capacitance range increased to 2000 mu F, upgraded and will test the attachment, increased the magnetic hanging belt make the operation more convenient, in addition to the quality assurance period extended to five years.

Produc雷竞技appt specifications: Fluke 17 b + IND digital multimeter

function range The resolution of the precision
Ac voltage
(40 Hz and 500 Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
Dc voltage 4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
Ac voltage (mv) 400.0 mV 0.1 mV 3.0% + 3
Dc voltage (mv) 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
resistance
(ohm)
400.0 Ω
4.000 k Ω
40.00 k Ω
400.0 k Ω
4.000 M Ω
40.00 M Ω
0.1 Ω
0.001 k Ω
0.01 k Ω
0.1 k Ω
0.001 M Ω
0.01 M Ω
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
capacitance3 40.00 the nF
400.0 the nF
4.000 u F
40.00 u F
400.0 u F
1000 mu F
2000 mu F
0.01 the nF
0.1 the nF
0.001 u F
0.01 u F
0.1 u F
1 u F
1 u F
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
5% + 5
frequency1
Hz
(10 Hz to 100 kHz)
50.00 the H2
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1% + 3
Duty ratio1 Between 1% and 99% 0.10% 1%, the typical case4
Alternating current mu A
(40 Hz and 400 Hz)
400.0 mu A
4000 mu A
0.1 mu A
1 mu A
1.5% + 3
Alternating current mA
(40 Hz and 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
Alternating current A
(40 Hz and 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Mu A dc current 400.0 mu A
4000 mu A
0.1 mu A
1 mu A
1.5% + 3
Dc current mA 40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
A dc current 4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
The temperature 50 ° C to 400 ° C
0 ° C - 50 ° C
- 55 ° C - 0 ° C
0.1 C 2% plus or minus 1 ° C
Plus or minus 2 ° C
9% plus or minus 2 ° C
backlight - - There are
1All current, frequency and duty ratio range is the range of 1% to 100%.Not less than 1% range of input value specified.
2Usually, the open circuit voltage of 2.0 V, short circuit current < 0.6 mA.
3Specification does not include the test leads capacitance and the capacitance plate caused by error (error range is 40 nF, highest 1.5 nF).
4Usually means the frequency is 50 Hz or 60 Hz, duty ratio between 10% and 90%.
function Overload protection Input impedance (nominal value) Common mode rejection ratio Normal mode rejection ratio
Ac voltage 1000 V1 > 10 M Ω < 100 pF In direct current flow,
50 Hz or 60 Hz, greater than 60 dB
-
Ac voltage (mv) 400 mV > 1 m Ω, < 100 pF When 50 Hz or 60 Hz, greater than 80 dB -
Dc voltage 1000 V1 > 10 M Ω < 100 pF In direct current flow, 50 Hz or 60 Hz, greater than 100 dB When 50 Hz or 60 Hz, greater than 60 dB
Dc voltage (mv) 400 mV > 1 m Ω, < 100 pF When 50 Hz or 60 Hz, greater than 80 dB -
1106V Hz maximum
General technical indicators
The highest voltage between any terminal and earthing 1000 V
Display (LCD) 6000 count, update 3 times per second
The battery type 15 a, 2 AA, NEDA IEC LR6
Battery life span Minimum 500 hours (LED test mode and 50 hours without load cases.Load case, the battery life depends on the kind of tested LED.)
The temperature
Working temperature 0 ° C to 40 ° C
Storage temperature - 30 ° to 60 ° C C
Relative humidity
Working humidity The condensation (< 10 ° C)
10 ° to 30 ° C, C less than or equal to 90% RH.
30 ° C to 40 ° C, less than or equal to 75%
40 M Ω range
10 ° to 30 ° C, C less than or equal to 80% RH.
30 ° C to 40 ° C, less than or equal to 70%
At an altitude of
Working temperature 2000 m
Storage temperature 12000 m
The temperature coefficient of 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C)
The current input fuse protection 440 mA, 1000 V of fuse,雷竞技app Fluke specified parts only.
11. A, 1000 v of fu雷竞技appse, Fluke specified parts only.
Volume (high x width x length) 183 x 91 x 49.5 mm
The weight of the 455 g
The IP rating IP 40
security IEC61010, IEC 61010-1-2-030 CAT III 600 V, the CAT II 1000 V, pollution level 2
Electromagnetic environment IEC 61326-1: portable
Class A equipment (industrial radio and communication equipment)1
1The product meet the requirement of industry (class A) electromagnetic devices, A salesman or A user that should be paid attention to.This equipment is suitable for the business environment, not suitable for family use.

17 b雷竞技app + models: Fluke IND digital multimeter

雷竞技appFluke 17 b + IND

contains

  • 雷竞技app17 b + IND Fluke digital multimeter
  • TL75 test pens and, with two protective cap
  • Magnetic hanging belt
  • 2 AA batteries
  • The user manual