雷竞技appFluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
The main features
雷竞技appFluke 116 Digital Multimeter. Designed by Electricians. Engineered by a Fluke.
- Built - in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: else prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- To hold, continuity, frequency and capacitance
- Min/Max/business with elapsed time to record the signal fluctuations
- Compact ergonomic design for one - handed operation
- Compatible with optional magnetic hanger (ToolPak ™)
- The CAT III 600 V safety rated
雷竞技appFluke 323 True RMS Clamp Meter. The Rugged. Reliable. Precise.
- 400 A AC current measurement
- 600 VAC and the DC voltage measurement
- True RMS AC voltage and current for accurate measurements on non - linear signals
- To hold measurement of up to 40 k Ω with continuity of detection
- Slim, ergonomic design
- The CAT III 600 V, 300 V/CAT IV safety rating
Produc雷竞技appts overview: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
Having the right tool for the job is essential. Having all the right tools when you need them is even better. The 雷竞技appFluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast - acting, general purpose clamp meter.
The 雷竞技appFluke 116 comes with The Fluke 80 bk - A integrated DMM temperature probe.No need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings under caused by ghost voltage雷竞技app. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures to hold, continuity, frequency, and capacitance and provides The Min/Max/business readings with elapsed time to record The signal fluctuations.
雷竞技appFluke 116 multimeters are independently * for safe use in CAT III 600 V environments.
True RMS measurements and optimized ergonomics make the 雷竞技appFluke 323 True RMS Clamp Meter the best general purpose Clamp Meter for ltd. and residential electricians. The Fluke 323 model is ideally suited for the current measurements of up to 400 A in tight cable compartments.
Together, the 雷竞技appFluke 116 HVAC Multimeter and 323 True RMS Clamp Meter difference electricians the right tools for the job.
Produc雷竞技appt specifications: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
雷竞技appFluke 116 HVAC Multimeter with Temperature and Microamps
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Surge protection, | 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 | |
The Display | 6000 counts, 4 updates per second | |
The Bar graph | 32 33 segments, updates per second | |
Operating temperature | - 10 ° C to + 50 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
'type | 9 volt Alkaline, NEDA 1604 a/IEC 6 lr61 | |
'life | 400 hours of typical, with backlight | |
Accuracy Specifications | ||
DC millivolts | The Range/Resolution | 600.0 mV / 0.1 mV |
Accuracy | Plus or minus ([% of reading] + [counts]) : 0.5% + 2 | |
DC volts | The Range/Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
Accuracy | Plus or minus ([% of reading] + [counts]) : 0.5% + 2 | |
Auto volts | The Range/Resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
AC millivolts creates True RMS | The Range/Resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC volts creates True RMS | The Range/Resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
Continuity | The Range/Resolution | Ω Ω / 1, 600 |
Accuracy | Beeper on < 20 Ω off > 250 Ω;Detects opens the or shorts of 500 mu s or longer. | |
Ohms | The Range/Resolution | 600.0 Ω / 0.1 Ω 6.000 k Ω Ω / 0.001 k 60.00 k Ω Ω / 0.01 k 600.0 k Ω Ω / 0.1 k Ω 6.000 M / 0.001 M Ω |
Accuracy | 0.9% + 1 | |
The Range/Resolution | Ω 40.00 M / 0.01 M Ω | |
Accuracy | 1.5% + 2 | |
Diode test | The Range/Resolution | 2.000 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | The Range/Resolution | 1000 nF / 1 nF 10.00 u F / 0.01 u F 100.0 u F / 0.1 u F 9999 mu F u F / 1 100 mu to 1000 mu F F |
Accuracy | 1.9% + 2 | |
The Range/Resolution | > 1000 mu F | |
Accuracy | 5% + 20% | |
LoZ capacitance | The Range | 1 nF to 500 mu F |
Accuracy | 10% + 2 typical | |
Temperature squared (Type K thermocouple) | The Range/Resolution | To 40 ° C to 400 ° C / 0.1 ° C |
Accuracy | 1% + 10 squared | |
The Range/Resolution | To 40 ° F to 752 ° F / 0.2 ° F | |
Accuracy | 1% + 18 squared | |
AC mu amps True RMS (45 Hz to 500 Hz) | The Range/Resolution | 600.0 mu A / 0.1 mu A |
Accuracy | 1.0% + 2 | |
DC mu amps | The Range/Resolution | 600.0 mu A / 0.1 mu A |
Accuracy | 1.0% + 2 | |
Hz (V or A input) squared | The Range/Resolution | 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto - V/LoZ are specified from 1% to 100% of the range. The Auto - V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. • Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. The Frequency is DC coupled, 45 Hz to 5 kHz for AC current. • Temperature Range/Resolution: - 40 ° F to 752 ° F / 0.2 ° F |
||
Mechanical and General Specifications | ||
The Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
giant | 3 years |
雷竞技appFluke 323 True RMS Clamp Meter
Specifications | ||
AC current | The Range | 400.0 A |
Accuracy | 2% plus or minus 5 who leads (45 Hz to 65 Hz) 2.5% plus or minus 5 who leads (65 Hz to 400 Hz) |
|
The AC voltage | The Range | 600.0 V |
Accuracy | 1.5% plus or minus 5 who leads | |
The DC voltage | The Range | 600.0 V |
Accuracy | 1.0% plus or minus 5 who leads | |
To hold | The Range/Resolution | 400.0 Ω Ω / 4000 |
Accuracy | 1.0% plus or minus 5 who leads | |
Continuity | 70 or less Ω | |
AC response | True RMS - | |
The Data hold | Yes | |
The Size | H x W x D (mm) | 207 x 75 x 34 |
Max wire diameter | 30 mm (MCM) 600 | |
Weight | 265 g | |
The Category rating | The CAT III 600 V The CAT IV 300 V |
|
giant | Two - year |
Mode雷竞技appl: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
Includes Multimeter and Clamp Meter
Manual + 雷竞技appresources: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
- 116 | user manual
- 323/324/325 | user manual
- 110/113/114/115/116/117 | to information security
- 114, 115, 116, and 117 | calibration manual
- 117, 116115114113 and 110 Plus statement | non-volatile memory
- 302 + / 303/305/323/324/325 | non-volatile memory
- 323/324/325 | calibration manual
- 323/324/325 | calibration manual addendum
- 323/324/325 | quick reference guide
- 雷竞技appFluke 116 True RMS Multimeter | quick reference guide