雷竞技appFluke MAX + 116/62 combination tool suite
The main features
- Built-in thermometer for HVAC applications
- Microamps of current sensors of the test flame
- Reading error caused by low input impedance can help prevent virtual voltage
- Wide bright white LED backlight screen, suitable for dark areas work
- True RMS voltage and current measurements, accurate measurement of nonlinear loads
- No current clamp, can be directly measured 10 A (20 A overload, for 30 seconds)
- Resistance, on and off, frequency, and capacitance
- Using the minimum/maximum/average and experience the timestamp records signal fluctuation
- For easy one-handed operation
- Optional magnetic pendant (ToolPak ™), hands free
- The CAT III 600 V safety level
- Measuring temperature: - 30 ° C to 650 ° C (22 ° F to 1202 ° F) -
- High accuracy, the accuracy of 雷竞技appup to + 1.0 ° C or + 1.0% reading (Fluke 62 MAX +)
- IP54 waterproof and dustproof, support for a rainy day, the sun, even dirty, dusty industrial environment
- Strong enough to bear 3 m fall.Even in the ladder work also need not worry
- Small, light,Can clip on the tool belt or belt loops, or easily into the toolbox
- Double laser: 62 MAX + has dual laser, helps to identify the area being measured
Produc雷竞技appts overview: Fluke MAX + 116/62 combination tool suite
Choose the right tool is very important for specific application;When need to have all the right tools is better.雷竞技appFluke 116/323 combination of HVAC tools suite provides you with multi-function, rugged multimeter and fast gm clip-on table.
雷竞技app116 is equipped with A Fluke Fluke 80 bk - A integrated digital multimeter temperature probe.Microamps function support as low as 0.1 microamps flame sensor.AutoV/LoZ function can prevent the error caused by virtual voltage readings.雷竞技appFluke 116 also has wide bright white LED backlight screen, suitable for in the area of insufficient light.Instrument can measure the resistance, on-off and capacitance, frequency, and provide experience time minimum/maximum average reading/to record the signal wave.
雷竞技appFluke 116 multimeter by independent testing, could be used for CAT III 600 v environment security.
雷竞技appFluke 62 MAX + infrared thermometer can meet all you needed.Small size, high accuracy, and easy to use.IP54 protection grade, dustproof and waterproof.High accuracy and strong and durable enough to withstand 3 m fall.
雷竞技appFluke 116 HVAC multimeter and 62 MAX + infrared thermometer for HVAC technical personnel to provide the right tools for the work.
Produc雷竞技appt specifications: Fluke MAX + 116/62 combination tool suite
雷竞技appFluke 116 multimeter
Technical indicators | ||
Any maximum voltage between terminals and grounding | 600 V | |
Surge protection | 6 kV peak, IEC 61010-1 600 V CAT III, pollution level 2 | |
According to | 6000 words, updated four times per second | |
Simulation indicate | 33 and update 32 times per second | |
Working temperature | - 10 ° C to + 50 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
The battery type | 9 v alkaline battery, NEDA 1604 a/IEC 6 lr61 | |
Battery life | 400 hours, typical values, no backlighting | |
The accuracy of technical indicators | ||
DC millivolt mV (DC) | Range /The resolution of the | 600.0 mV / 0.1 mV |
The accuracy of | Plus or minus (reading [%] + [word]) : 0.5% + 2 | |
DC voltage (DC V) | Range /The resolution of the | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
The accuracy of | Plus or minus (reading [%] + [word]) : 0.5% + 2 | |
Automatic voltage | range | 600.0 V / 0.1 V |
The accuracy of | 2.0% + 3 (dc, 45 Hz - 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
AC millivolts (AC) mV1True RMS, | range | 600.0 mV / 0.1 mV |
The accuracy of | 1.0% + 3 (dc, 45 Hz - 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
AC voltage (AC V)1True RMS | Range /The resolution of the | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
The accuracy of | 1.0% + 3 (dc, 45 Hz - 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
On and off sex | range | Ω Ω / 1, 600 |
The accuracy of | Hum @ < 20 Ω, closing @ > 250 Ω;Test 500 mu s or more open or short circuit. | |
resistance | Range /The resolution of the | 600.0 Ω / 0.1 Ω 6.000 k Ω Ω / 0.001 k 60.00 k Ω Ω / 0.01 k 600.0 k Ω Ω / 0.1 k Ω 6.000 M / 0.001 M Ω |
The accuracy of | 0.9% + 1 | |
Range/resolution | Ω 40.00 M / 0.01 M Ω | |
The accuracy of | 1.5% + 2 | |
Diode test | Range /The resolution of the | 2.000 V / 0.001 V |
The accuracy of | 0.9% + 2 | |
capacitance | Range /The resolution of the | 1000 nF / 1 nF 10.00 u F / 0.01 u F 100.0 u F / 0.1 u F 9999 mu F u F / 1 100 mu to 1000 mu F F |
The accuracy of | 1.9% + 2 | |
Range/resolution | > 1000 mu F | |
The accuracy of | 5% + 20% | |
LoZ capacitance | range | 1 nF - 500 u F |
The accuracy of | 10% + 2, typical values | |
The temperature2(K type thermocouple) | Range /The resolution of the | To 40 ° C to 400 ° C / 0.1 ° C |
The accuracy of2 | 1% + 10 | |
Range /The resolution of the | To 40 ° F to 752 ° F / 0.2 ° F | |
The accuracy of2 | 1% + 18 | |
Exchange microamps (AC) mu A, true RMS (45 Hz - 500 Hz) | Range /The resolution of the | 600.0 mu A / 0.1 mu A |
The accuracy of | 1.0% + 2 | |
DC microamps (DC mu A) | Range /The resolution of the | 600.0 mu A / 0.1 mu A |
The accuracy of | 1.0% + 2 | |
Hz (V or A input)2 | Range /The resolution of the | 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz |
The accuracy of | 0.1% + 2 | |
1. In addition to the Auto - V/LoZ, all ac voltage range is from 1% to 100% range;Auto - V/LoZ start at 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. • for ac voltage and frequency for exchange coupling, 5 Hz to 50 kHz.For alternating current, the frequency for a dc coupling, 45 Hz to 5 kHz. Temperature range/resolution: to 40 ° F to 752 ° F / 0.2 ° F. |
||
Machinery and general index | ||
size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
The weight of the | 550 g | |
The quality assurance | 3 years |
雷竞技appFluke 62 MAX + infrared thermometer
Technical indicators | ||
Temperature range: | - 30 ° C to 650 ° C (22 ° F to 1202 ° F) - | |
The accuracy of | + / - 1.0 ° C or reading plus or minus 1.0%, of great value - 10 ° C to 0 ° C: + / - 2.0 - 30 ° to 10 ° C - C: + / - 3.0 |
|
Response time (95%). | < 300 ms (95% reading) | |
Spectral response: | 8 to 14 microns | |
emissivity | 0.10 to 1.00 | |
Optical resolution | Whoever (90% energy calculated) | |
Display resolution | 0.1 ° C (0.2 ° F) | |
Reading repeatability | Plus or minus 0.5% reading or < plus or minus 0.5 ° C (1 ° F), of great value | |
The power supply | Type AA batteries | |
Battery life | 8 hours, laser and open backlighting | |
The physical technical indicators | ||
The weight of the | 255 g (8.99 oz) | |
size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Working temperature | 0 ° C to 50 ° C (32 ° F to 122 ° F) | |
Storage temperature | - 20 ° to 60 ° C - C (4 ° F to 140 ° F), (including battery) | |
Working humidity | Between 10% and 90% RH no condensation @ 30 ° C (86 ° F) | |
Work at an altitude of | An average of 2000 meters above sea level | |
Stored at an altitude of | An average of 12000 meters above sea level | |
The IP rating | IP 54, IEC 60529 | |
Drop test | 3 m | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:6 now, EN 61326-06 | |
Standards and certification body | compliance | EN/IEC 61010-1:2001 |
Laser safety | The FDA and EN 60825-1, class II |
Mode雷竞技appls: Fluke MAX + 116/62 combination tool suite
- 雷竞技appFluke 116 HVAC multimeter and microamps of current
- 雷竞技appFluke 62 infrared thermometer
- Quad TL75 Hard Point test
- TPak ToolPak magnetic multimeter accessories
- The flexible belt casing tongs thermocouple
- 80 bk integrated temperature sensor
- 80 ak thermocouple adapter
- With C115 luxury soft bag, shoulder straps