雷竞技appFluke 1587 / ET electric fault diagnosis and eliminate senior suite
Has been discontinued
The main features
雷竞技appFluke 1587
Insulation multimeter
- Us雷竞技apping the Fluke 1587 insulation test, as well as a variety of digital multimeter, reliable and easy to use.
- In one tool: powerful fully functional multimeter
- Ideal tool of dealing with the motor, cable and switch gear.
- Wide screen, backlight.
- Filter, suitable for motor driven measurement.
- Insulation test (0.01 M Ω Ω to 2 G).
- Insulation test voltage (50 V, 100 V, 250 V, 500 V, 1000 V), applicable to a variety of applications.
- 1000 V / 600 V IV CAT CAT III overvoltage safe level, to provide users with additional protection.
- 雷竞技appUsed together with Fluke Fluke i400 1587, can accurately measure the alternating current, do not need to disconnect the circuit.
- U雷竞技appsed with Fluke 1587, 1 A, AC - 400 - A AC measurement.
- 1 mA/A output, to ensure easy reading.
- 1000 V / 600 V IV CAT CAT III overvoltage safe level, to provide users with additional protection.
- Specially designed, can be in a very compact size under provides maximum usefulness.
- Conductor: the biggest Ø 32 mm.
- Dustproof water: IP54.
- Solid: through 3 meters (9.8 feet) drop test.
- Ergonomics design: a complete redesign, feel more natural.
- Distance coefficient ratio: now.
- Double laser: identify the area being measured.
- Wide screen: even in the dark environment, also can read data easily.
This product has been discontinued or reclassified
Produc雷竞技appts overview: Fluke 1587 / ET electrical failure diagnosis and elimination of senior suite
The suite of products selected, suitable for failure diagnosis and elimination, and preventive maintenance applications.
Develop a plan of preventive maintenance is becoming more and more important, which can maintain the normal operation of electrical equipment, and significantly reduce planned and unplanned downtime.Unplanned downtime cost is hard to calculate, but are often very large.For some industries, the annual costs may account for 1% to 3% of the income (profit may be 30% to 40%).
contains 雷竞技appFluke 1587 Insulation multimeter, 雷竞技appFluke i400 Current clamp and 雷竞技appFluke 62 Mini infrared thermometer.
Develop a plan of preventive maintenance is becoming more and more important, which can maintain the normal operation of electrical equipment, and significantly reduce planned and unplanned downtime.Unplanned downtime cost is hard to calculate, but are often very large.For some industries, the annual costs may account for 1% to 3% of the income (profit may be 30% to 40%).
contains 雷竞技appFluke 1587 Insulation multimeter, 雷竞技appFluke i400 Current clamp and 雷竞技appFluke 62 Mini infrared thermometer.
- Us雷竞技apping the Fluke 1587 insulation test, as well as a variety of digital multimeter, reliable and easy to use.
- 雷竞技appUsed together with Fluke Fluke i400 1587, can accurately measure the alternating current, do not need to disconnect the circuit.
- Using 62 Max + non-contact thermometer to check the high temperature and measured temperature.
Produc雷竞技appt specifications: Fluke 1587 / ET electrical failure diagnosis and elimination of senior suite
Technical indicators | ||
DC DC voltage (V) | The highest voltage | 1000 V |
The accuracy of | Plus or minus 0.09% (+ 2) | |
The highest resolution | 0.001 V | |
AC voltage (V) | The highest voltage | 1000 V |
The accuracy of | Plus or minus 2% (+ 3) | |
Communication bandwidth | 5 kHz1 | |
1. Low pass filter;3 db @ 800 Hz | ||
The highest resolution | 0.1 mV | |
Direct current (DC) a. | Maximum current | 400 mA |
Accuracy of current | Plus or minus 0.2% (+ 2) | |
The highest resolution | 0.01 mA | |
Alternating current (AC) a. | Maximum current | 400 mA |
Accuracy of current | Plus or minus 1.5% (+ 2)1 | |
1.1 kHz bandwidth | ||
The highest resolution | 0.01 mA | |
resistance | The biggest resistance | 50 M Ω |
The accuracy of | Plus or minus 0.9% (+ 2) | |
The highest resolution | 0.1 Ω | |
capacitance | The largest capacity | 9999 (including F |
The accuracy of | Plus or minus 1.2% (+ 2) | |
The highest resolution | 1 nF | |
frequency | Maximum frequency | 100 kHz |
The accuracy of | Plus or minus 0.1% (+ 1) | |
The highest resolution | 0.01 Hz | |
Temperature measurement | 40.0 ° C to 537 ° C 40.0 ° F to 998 ° F Does not contain the probe |
|
Diode test | range | 6 V |
The resolution of the | 1 mV | |
The accuracy of | Plus or minus 2% (+ 1) | |
Insulation test | ||
Minimum test current Ω @ 1 k/V | 1 mA | |
The test voltage | 50, 100, 250, 500, 1000 V | |
The maximum resistance @ test voltage | 50 V | |
100 V | ||
250 V | ||
500 V | ||
1000 V | 2 G Ω | |
The highest resolution @ test voltage | 50 V | 0.01 M Ω |
100 V | 0.01 M Ω | |
250 V | 0.1 M Ω | |
500 V | 0.1 M Ω | |
1000 V | 0.1 M Ω | |
@ testing voltage precision | 50 V | Plus or minus 3% (+ 5) |
100 V | Plus or minus 3% (+ 5) | |
250 V | Plus or minus 1.5% (+ 5) | |
500 V | Plus or minus 1.5% (+ 5) | |
1000 V | + + 5 (1.5%), less than 600 M Ω;Plus or minus 10% (+ 3), up from 600 M Ω | |
Environmental technology indicators | ||
Working temperature | - 20 ° C to + 55 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
No condensation (humidity) | 0% to 95% (10 ° C - 30 ° C) | |
0% - 75% (30 ° C - 40 ° C) | ||
0% - 40% (40 ° C - 55 ° C) | ||
Work at an altitude of | 2000 m. | |
Safety indicators | ||
Overpressure analogy | Meet the ANSI/ISA 82.02.01 (2004, 61010-1) CAN/CSA - C22.2 NO. 61010-1-04 and IEC/EN 61010-1 version 2 about measuring the CAT III and IV CAT 600 V, 1000 V | |
Accredited institution | 2000 MB of 1000 V, the CAT CAT III IV 600 V;3000 m CAT II III 600 V 1000 V, the CAT | |
Machinery and general index | ||
size | 203 x 100 x 50 mm (including sheath) | |
The weight of the | 624 g | |
The quality assurance | 3 years | |
Alkaline battery life | When using a multimeter | 1000 hours |
Insulation testing | Room temperature, a new alkaline battery insulation testing support at least 1000 times.1000 V,1MΩ标准测试,占空比为5秒开,25秒关。 | |
The IP rating | IP40 |
雷竞技appFluke i400 alternating current clamp
Technical indicators | |
Nominal current range | 400 A |
Continuous current range | 1 A - 400 - A |
The biggest non-destructive current | 1000 A |
Minimum current measurement | 1 A |
The basic accuracy | 2% + 0.06 A (45-400 Hz) Readouts + basic indicators (%) |
Frequencies available | 5 Hz and 20 kHz |
Output level | 1 mA/A |
Safety indicators | |
security | The CAT IV III 1000 V 600 V, the CAT |
The highest voltage | 1000 V AC RMS ground so as to meet the requirements of EN61010 |
Machinery and general index | |
The quality assurance | 1 year |
Maximum conductor diameter | 32 mm (1.25 in) |
The largest conductor size (bus) | 750 MCM |
The output cable length | 1.5 m (59) in |
Sheathed banana plug | is |
雷竞技appFluke 62 MAX + infrared thermometer
Technical indicators | ||
Temperature range: | - 30 ° C to 650 ° C (22 ° F to 1202 ° F) - | |
The accuracy of | + / - 1.0 ° C or reading plus or minus 1.0%, of great value - 10 ° C to 0 ° C: + / - 2.0 - 30 ° to 10 ° C - C: + / - 3.0 |
|
Response time (95%). | 雷竞技appFluke 62 MAX + | < 300 ms (95% reading) |
Spectral response | 8 to 14 microns | |
emissivity | 0.10 to 1.00 | |
Optical resolution | Whoever (90% energy calculated) | |
Display resolution | 0.1 ° C (0.2 ° F) | |
Reading repeatability | Plus or minus 0.5% reading or < plus or minus 0.5 ° C (1 ° F), of great value | |
The power supply | Type AA batteries | |
Battery life | 8 hours, laser and open backlighting | |
The physical technical indicators | The weight of the | 255 g (8.99 oz) |
size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Working temperature | 0 ° C to 50 ° C (32 ° F to 122 ° F) | |
Storage temperature | - 20 ° to 60 ° C - C (4 ° F to 140 ° F), (including battery) | |
Working humidity | Between 10% and 90% RH no condensation @ 30 ° C (86 ° F) | |
Work at an altitude of | An average of 2000 meters above sea level | |
Stored at an altitude of | An average of 12000 meters above sea level | |
The IP rating | IP 54, IEC 60529 | |
Drop test | 3 m | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:6 now, EN 61326-06 | |
Standards and certification body | compliance | EN/IEC 61010-1:2001 |
Laser safety | The FDA and EN 60825-1, class II |
Mode雷竞技appl: Fluke 1587 / ET electric fault diagnosis and eliminate senior suite
雷竞技appFluke 1587 / ET Kit
雷竞技appFluke 1587 / ET electric fault diagnosis and eliminate senior suite
Standard:
- 雷竞技appFluke 1587 insulation multimeter
- 雷竞技appFluke i400 current clamp
- 雷竞技appFluke 62 MAX + infrared thermometer