China

雷竞技app15 b PRO multimeter Fluke

  • 雷竞技appFluke PRO 15 b
New product

The main features

  • 600 V Cat III safety design index
  • Large range of 50%, backlight is bright white
  • Voltage, resistance, current, capacitance
  • Input terminal of ac and dc current measurement value of 10 A
  • Diode test, and maintain data

Produc雷竞技appts overview: Fluke 15 b PRO multimeter

At work, you need a durable, reliable and accurate digital multimeter.雷竞技appFluke PRO 15 bDigital multimeter可满足甚至超出您的需求。Fluke 15B PRO 易于使用,只需要一只手操作,甚至在带手套的时候也可以灵活操作,可满足您的所有需求。

Produc雷竞技appt specifications: Fluke 15 b PRO multimeter

Precision specifications
Can keep 1 year after the calibration accuracy, the work temperature of 18 ° C to 28 ° C, relative humidity of 0% to 75%.Accuracy specification form is as follows: plus or minus (reading % + the least significant digits).

function range The resolution of the precision
Ac voltage
(40 Hz and 500 Hz)1
4.000 V 0.001 V 1.0% + 3
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V
Dc voltage 4.000 V 0.001 V 0.5% + 3
40.00 V 0.01 V
400.0 V 0.1 V
1000 V 1 V
Ac voltage (mv) 400.0 mV 0.1 mV 3.0% + 3
Dc voltage (mv) 400.0 mV 0.1 mV 1.0% + 10
Diode test2 2.000 V 0.001 V 10%
resistance
(ohm)
400.0 Ω 0.1 Ω 0.5% + 3
4.000 k Ω 0.001 k Ω 0.5% + 2
40.00 k Ω 0.01 k Ω 0.5% + 2
400.0 k Ω 0.1 k Ω 0.5% + 2
4.000 M Ω 0.001 M Ω 0.5% + 2
40.00 M Ω 0.01 M Ω 1.5% + 3
capacitance3 40.00 the nF 0.01 the nF 2% + 5
400.0 the nF 0.1 the nF 2% + 5
4.000 u F 0.001 u F 5% + 5
40.00 u F 0.01 u F 5% + 5
400.0 u F 0.1 u F 5% + 5
1000 mu F 1 u F 5% + 5
Alternating current mu A
(40 Hz and 400 Hz)
400.0 mu A 0.1 mu A 1.5% + 3
4000 mu A 1 mu A
Alternating current mA
(40 Hz and 400 Hz)
40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
Alternating current A
(40 Hz and 400 Hz)
4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
Mu A dc current 400.0 mu A 0.1 mu A 1.5% + 3
4000 mu A 1 mu A
Dc current mA 40.00 mA 0.01 mA 1.5% + 3
400.0 mA 0.1 mA
A dc current 4.000 A 0.001 A 1.5% + 3
10.00 A 0.01 A
backlight There are
1All current, frequency and duty ratio range is the range of 1% to 100%.Not less than 1% range of input value specified.
2Usually, the open circuit voltage of 2.0 V, short circuit current < 0.6 mA.
3Specification does not include the test leads capacitance and the capacitance plate caused by error (error range is 40 nF, highest 1.5 nF).
function Overload protection Input impedance (nominal value) Common mode rejection ratio Normal mode rejection ratio
Ac voltage 1000 V1 > 10 M Ω < 100 pF In direct current flow, 50 Hz or 60 Hz, greater than 60 dB -
Ac voltage (mv) 400 mV > 1 m Ω, < 100 pF When 50 Hz or 60 Hz, greater than 80 dB -
Dc voltage 1000 V1 > 10 M Ω < 100 pF In direct current flow, 50 Hz or 60 Hz, greater than 100 dB When 50 Hz or 60 Hz, greater than 60 dB
Dc voltage (mv) 400 mV > 1 m Ω, < 100 pF When 50 Hz or 60 Hz, greater than 80 dB -
1106V Hz maximum
General technical indicators
The highest voltage between any terminal and earthing 1000 V
Display (LCD) 4000 count, update 3 times per second
The battery type 15 a, 2 AA, NEDA IEC LR6
Battery life span Minimum 500 hours (LED test mode and 50 hours without load cases.Load case, the battery life depends on the kind of tested LED.)
The temperature
Working temperature 0 ° C to 40 ° C
Storage temperature - 30 ° to 60 ° C C
Relative humidity
Working humidity The condensation (< 10 ° C)
10 ° to 30 ° C, C less than or equal to 90% RH.
30 ° C to 40 ° C, less than or equal to 75%
40 M Ω range
10 ° to 30 ° C, C less than or equal to 80% RH.
30 ° C to 40 ° C, less than or equal to 70%
At an altitude of
Working temperature 2000 m
Storage temperature 12000 m
The temperature coefficient of 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C)
The current input fuse protection 440 mA, 1000 V of fuse,雷竞技app Fluke specified parts only.
11. A, 1000 v of fu雷竞技appse, Fluke specified parts only.
Volume (high x width x length) 183 x 91 x 49.5 mm
The weight of the 455 g
The IP rating IP 40
security IEC61010, IEC 61010-1-2-030 CAT III 600 V, the CAT II 1000 V, pollution level 2
Electromagnetic environment IEC 61326-1: portable
Electromagnetic compatibility Only applicable in Korea
Class A equipment (industrial radio and communication equipment)1
1The product meet the requirement of industry (class A) electromagnetic devices, A salesman or A user that should be paid attention to.This equipment is suitable for the business environment, not suitable for family use.

PRO 雷竞技appmultimeter model: Fluke 15 b

雷竞技appFluke PRO 15 b

PRO雷竞技app multimeter model: Fluke 15 b

  • 雷竞技app15 b PRO multimeter Fluke
  • TL75 test leads, with two hats
  • 2 AA batteries
  • The user manual