雷竞技app15 b PRO multimeter Fluke
New product
The main features
- 600 V Cat III safety design index
- Large range of 50%, backlight is bright white
- Voltage, resistance, current, capacitance
- Input terminal of ac and dc current measurement value of 10 A
- Diode test, and maintain data
Produc雷竞技appts overview: Fluke 15 b PRO multimeter
At work, you need a durable, reliable and accurate digital multimeter.雷竞技appFluke PRO 15 bDigital multimeter可满足甚至超出您的需求。Fluke 15B PRO 易于使用,只需要一只手操作,甚至在带手套的时候也可以灵活操作,可满足您的所有需求。
Produc雷竞技appt specifications: Fluke 15 b PRO multimeter
Precision specifications
Can keep 1 year after the calibration accuracy, the work temperature of 18 ° C to 28 ° C, relative humidity of 0% to 75%.Accuracy specification form is as follows: plus or minus (reading % + the least significant digits).
function | range | The resolution of the | precision |
Ac voltage (40 Hz and 500 Hz)1 |
4.000 V | 0.001 V | 1.0% + 3 |
40.00 V | 0.01 V | ||
400.0 V | 0.1 V | ||
1000 V | 1 V | ||
Dc voltage | 4.000 V | 0.001 V | 0.5% + 3 |
40.00 V | 0.01 V | ||
400.0 V | 0.1 V | ||
1000 V | 1 V | ||
Ac voltage (mv) | 400.0 mV | 0.1 mV | 3.0% + 3 |
Dc voltage (mv) | 400.0 mV | 0.1 mV | 1.0% + 10 |
Diode test2 | 2.000 V | 0.001 V | 10% |
resistance (ohm) |
400.0 Ω | 0.1 Ω | 0.5% + 3 |
4.000 k Ω | 0.001 k Ω | 0.5% + 2 | |
40.00 k Ω | 0.01 k Ω | 0.5% + 2 | |
400.0 k Ω | 0.1 k Ω | 0.5% + 2 | |
4.000 M Ω | 0.001 M Ω | 0.5% + 2 | |
40.00 M Ω | 0.01 M Ω | 1.5% + 3 | |
capacitance3 | 40.00 the nF | 0.01 the nF | 2% + 5 |
400.0 the nF | 0.1 the nF | 2% + 5 | |
4.000 u F | 0.001 u F | 5% + 5 | |
40.00 u F | 0.01 u F | 5% + 5 | |
400.0 u F | 0.1 u F | 5% + 5 | |
1000 mu F | 1 u F | 5% + 5 | |
Alternating current mu A (40 Hz and 400 Hz) |
400.0 mu A | 0.1 mu A | 1.5% + 3 |
4000 mu A | 1 mu A | ||
Alternating current mA (40 Hz and 400 Hz) |
40.00 mA | 0.01 mA | 1.5% + 3 |
400.0 mA | 0.1 mA | ||
Alternating current A (40 Hz and 400 Hz) |
4.000 A | 0.001 A | 1.5% + 3 |
10.00 A | 0.01 A | ||
Mu A dc current | 400.0 mu A | 0.1 mu A | 1.5% + 3 |
4000 mu A | 1 mu A | ||
Dc current mA | 40.00 mA | 0.01 mA | 1.5% + 3 |
400.0 mA | 0.1 mA | ||
A dc current | 4.000 A | 0.001 A | 1.5% + 3 |
10.00 A | 0.01 A | ||
backlight | There are | ||
1All current, frequency and duty ratio range is the range of 1% to 100%.Not less than 1% range of input value specified. 2Usually, the open circuit voltage of 2.0 V, short circuit current < 0.6 mA. 3Specification does not include the test leads capacitance and the capacitance plate caused by error (error range is 40 nF, highest 1.5 nF). |
function | Overload protection | Input impedance (nominal value) | Common mode rejection ratio | Normal mode rejection ratio |
Ac voltage | 1000 V1 | > 10 M Ω < 100 pF | In direct current flow, 50 Hz or 60 Hz, greater than 60 dB | - |
Ac voltage (mv) | 400 mV | > 1 m Ω, < 100 pF | When 50 Hz or 60 Hz, greater than 80 dB | - |
Dc voltage | 1000 V1 | > 10 M Ω < 100 pF | In direct current flow, 50 Hz or 60 Hz, greater than 100 dB | When 50 Hz or 60 Hz, greater than 60 dB |
Dc voltage (mv) | 400 mV | > 1 m Ω, < 100 pF | When 50 Hz or 60 Hz, greater than 80 dB | - |
1106V Hz maximum |
General technical indicators | |
The highest voltage between any terminal and earthing | 1000 V |
Display (LCD) | 4000 count, update 3 times per second |
The battery type | 15 a, 2 AA, NEDA IEC LR6 |
Battery life span | Minimum 500 hours (LED test mode and 50 hours without load cases.Load case, the battery life depends on the kind of tested LED.) |
The temperature | |
Working temperature | 0 ° C to 40 ° C |
Storage temperature | - 30 ° to 60 ° C C |
Relative humidity | |
Working humidity | The condensation (< 10 ° C) 10 ° to 30 ° C, C less than or equal to 90% RH. 30 ° C to 40 ° C, less than or equal to 75% |
40 M Ω range 10 ° to 30 ° C, C less than or equal to 80% RH. 30 ° C to 40 ° C, less than or equal to 70% |
|
At an altitude of | |
Working temperature | 2000 m |
Storage temperature | 12000 m |
The temperature coefficient of | 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C) |
The current input fuse protection | 440 mA, 1000 V of fuse,雷竞技app Fluke specified parts only. 11. A, 1000 v of fu雷竞技appse, Fluke specified parts only. |
Volume (high x width x length) | 183 x 91 x 49.5 mm |
The weight of the | 455 g |
The IP rating | IP 40 |
security | IEC61010, IEC 61010-1-2-030 CAT III 600 V, the CAT II 1000 V, pollution level 2 |
Electromagnetic environment | IEC 61326-1: portable |
Electromagnetic compatibility | Only applicable in Korea |
Class A equipment (industrial radio and communication equipment)1 1The product meet the requirement of industry (class A) electromagnetic devices, A salesman or A user that should be paid attention to.This equipment is suitable for the business environment, not suitable for family use. |
PRO 雷竞技appmultimeter model: Fluke 15 b
雷竞技appFluke PRO 15 b
PRO雷竞技app multimeter model: Fluke 15 b
- 雷竞技app15 b PRO multimeter Fluke
- TL75 test leads, with two hats
- 2 AA batteries
- The user manual