China

雷竞技appFluke 16 General Purpose Meter for HVAC

  • 雷竞技appFluke 16 1500 x1000-1

The main features

  • Accurate temperature measurement from 40 to 400 ° C
  • Confidently test flame sensor circuits with microamp microamps measurement down to 0.1
  • Capacitance of up to 10000 microfarads
  • 0.9%, basic DC accuracy
  • The count of 4000 digital display
  • Min/Max recording with relative time stamp records the highest and lowest voltage readings during a 100 - hour period
  • Automatic or manual held
  • High hold ranges to 40 megohms
  • Millivolt range for compatibility with other accessories
  • V - Check ™ mode is designed for safety
  • When measuring ohms, continuity, or diode test modes, the meter automatically switches to measuring ac or dc volts if wining 4.5 V is present
  • Continuity Capture ™ locates intermittent opens as brief as 250 microseconds and identifies them in a -- display as short - to - open or open - to - short
  • Sleep mode preserves' life

Produc雷竞技appts overview: Fluke 16 General Purpose Meter for HVAC

The 雷竞技appFluke 16 measures temperature quickly and accurately. The Standard equipment includes an 80 bk integrated DMM temperature probe. A microamp function is included for flame sensor measurements down to 0.1 microamps. Use The Fluke to test motor start and run capacitors on up to 10000 microfarads. Rely on The Fluke 16 to make your everyday measurements - up to 600 volts ac or dc, 40 megohms, diode test and exceptionally fast continuity.

Produc雷竞技appt specifications: Fluke 16 General Purpose Meter for HVAC

Specifications
Voltage DC
Maximum: 600 V
Accuracy: 0.9% (+ 1)
Maximum Resolution: 1 mV
Voltage AC
Maximum: 600 V
Accuracy: (1.9% + 2)
Maximum Resolution: 1 mV
Bandwith: 50 to 400 Hz
The Current DC
Maximum: 200 (including A
Accuracy: 1% + 2
Maximum Resolution: 0.1 (including A
The Current AC
Maximum: 200 (including A
Accuracy: 2% + 3
Maximum Resolution: 0.1 (including A
Bandwith: 50 to 400 Hz
To hold
Maximum: 40 M Ω
Accuracy: 0.9% + 1
Maximum Resolution: 0.1 Ω
Capacitance
Maximum: 10.000 (including F
Accuracy: 1.9% + 2
Maximum Resolution: 0.001 (including F
Diode
Maximum: 2.000 V
Accuracy: (1.9% + 2)
Resolution: 1 mV
Temperature
The Range: - 10 to 400 ° C
Accuracy: (1% + 0.8 ° C) (typical)
Maximum Resolution: 0.1 ° c.
Continuity
Beeper on The < 25 Ohm
Beeper off > 250 Ohm
Environmental Specifications
Operating Temperature
- 10 ° C to 50 ° C
Storage Temperature
30 ° to 60 ° C - C indefinitely
(40 ° C for 100 HRS) to -
Humidity (Without Condensation)
0% to 90% (10 ° to 35 ° C - C)
0% to 70% (35 ° C to 50 ° C)
Temperature Coefficient
(0.1 x specified accuracy) / ° C (18 ° C or > < 28 ° C)
Safety Specifications
Overvoltage category
EN 61010-1 to 600 v CAT III
Mechanical & General Specifications
The Size
(H x W x L) : 3.46 cm x 7.05 cm x 14.23 cm
1.35 in x 2.75 in x 5.55 in ()
Weight
286 g
giant
3 years
'Life
Alkaline: ~ 650 hours of typical

Mode雷竞技appl: Fluke 16 General Purpose Meter for HVAC

雷竞技appFluke 16
雷竞技appFluke 16 General Purpose Meter for HVAC

Includes:

  • 80 bk integrated DMM temperature probe
  • C10 Holster
  • The Test Leads
  • The Users manual