雷竞技appFluke 3000 FC HVAC systems
The main features
FC wireless HVAC system provides all of the common electrical parameters measurement
Wit雷竞技apph a Fluke Connect ® application of Fluke 3000 FC series wireless multimeter can satisfy all needs of convenient testing and measuring troubleshooting:
- Ac and dc voltage measurement, up to 1000 V
- Ac and dc current is 0.01 mA resolution
- Connectivity, resistance, diode testing, capacitance and frequency measurement
- Minimum/maximum record
- The CAT III 1000 V, the CAT IV 600 V;IP54
雷竞技appFluke a3000 FC wireless communication convenient current clamp module can meet all needs of test and measurement troubleshooting:
- True RMS ac current clamp table
- Measured 400 A alternating current (ac)
- It is used as instrument independently or as part of the system
- For logging, used to record and save as many as 65000 readings
- Surge function
Wit雷竞技apph the help of a Fluke t3000 FC wireless type K temperature module, you can:
- It is used as instrument independently or as part of the system
- For logging, used to record and save as many as 65000 readings
Produc雷竞技appts overview: Fluke 3000 FC HVAC systems
雷竞技appFluke FC HVAC system enables you to use remote wireless module current and temperature faster, safer and more convenient to electrical panel operations
FC wireless communication current clamp module is connected to your test points, and wireless digital multimeter at FC on the result of the scope of view as far as 20 meters.In addition, you can connect to wireless K type t3000 FC wireless temperature module, and view the remote temperature measurement value.
You'll save time, without resistance.the collect multiple measurements.The three-phase system is measur雷竞技apped using multiple modules, can be used as independent measurement tools, or with other Fluke Connect ® frequent testing module combined into a system.
In short, you can even check module reading through closed electrical panel.In addition, no雷竞技app manual record data, because the Fluke Connect remote module USES optional PC adapter can capture up to 65000 groups of min/Max with timestamp/average readings.雷竞技appFluke Connect wireless test tool also by you in the position of the separation of the test point view reading, to improve safety.
Now, you can get in the operation of the reading on the machinery and equipment, only there is a damage risk measurement module.
Produc雷竞技appt specifications: Fluke 3000 FC HVAC system
雷竞技appFluke 3000 FC series wireless multimeter
* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).
Detailed technical indicators | |||||
Ac voltage | |||||
Range creates/resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
||||
Precision squared after4 | 45 Hz - 500 Hz | 1.0% + 3 | |||
500 Hz to 1 kHz | 2.0% + 3 | ||||
1. All ac voltage range has been designated as the range of 1% to 100%. 2. The full scale highest do not exceed 500 V the crest factor of 3 or less, at 1000 V linear low crest factor < 1.5. Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading). 4. Do not over 107 V - Hz. |
|||||
Dc voltage, connectivity, resistance, diode test and capacitance | |||||
function | |||||
The mV | Range/resolution | 600.0 mV / 0.1 mV | |||
precision | 0.09% + 2 | ||||
V | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
|||
precision | 0.09% + 2 0.15% + 2 |
||||
))) | Range/resolution | Ω Ω / 1, 600 | |||
precision | < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit. | ||||
Ω | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 k Ω Ω / 0.001 k 60.00 k Ω Ω / 0.01 k 60.00 k Ω Ω / 0.1 k 600.0 k Ω Ω / 0.001 M Ω 50.00 M / 0.01 M Ω |
|||
precision | 0.5% + 2 0.5% + 1 1.5% + 3 |
||||
Diode test | Range/resolution | 2.000 V / 0.001 V | |||
precision | 1% + 2 | ||||
Including F | Range/resolution | 1000 nF / 1 nF 10.00 u F / 0.01 u F 100.0 u F / 0.1 u F 9999 mu F1 /1 u F |
|||
precision | 1.2% + 2 10% of the typical |
||||
Creates under 9999 mu F range measuring 1000 mu F capacitance, the measuring accuracy of 1.2% + 2. | |||||
Ac and dc current | |||||
function | |||||
MA communication (45 Hz to 1 kHz) |
Range creates/ resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|||
precision | 1.5% + 3 | ||||
MA DC squared | Range creates/resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|||
precision | 0.5% + 3 | ||||
1. All alternating current range has designated range of 5% to 100%. 2. Enter the load voltage (typical) : 400 mA input 2 mV/mA. 3. According to the 400 mA specified accuracy, overload of 600 mA. |
|||||
frequency | |||||
Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz |
||||
Precision creates | 0.1% + 1 | ||||
Creates the specified voltage frequency up to 99.99 kHz, current frequency up to 10 kHz. | |||||
The input features | |||||
function | overload To protect the |
The input impedance (nominal value) |
Common mode rejection ratio (1 k Ω non-equilibrium) | Norm inhibition | |
1100 Vrms | > 10 M Ω < 100 pF | In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | At 50 Hz or 60 Hz greater than 60 dB | ||
1100 Vrms | > 10 M Ω < 100 pF | When the dc to 60 Hz, or more than 60 dB | At 50 Hz or 60 Hz greater than 60 dB | ||
1100 Vrms | > 10 M Ω < 100 pF | In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | At 50 Hz or 60 Hz greater than 60 dB | ||
Open circuit voltage | Full scale voltage | Typical short-circuit current | |||
To 6 M Ω | 50 M Ω | Typical short-circuit current | |||
1100 Vrms | < 2.7 VDC | < 0.7 VDC | < 0.9 VDC | < 350 mA, | |
1100 Vrms | < 2.7 VDC | 2.000 VDC | < 1.1 mA | ||
MA function | |||||
Overload protection | 44/100 fuse, A, 1000 V, fuse | ||||
overload | 600 mA overload for up to 2 minutes, at least 10 minutes to a halt | ||||
Minimum/maximum record accuracy | |||||
Dc function | Specify the precision of the measurement function, duration of > 350 milliseconds for counting + 12 times of change. | ||||
Communication function | Specify the precision of the measurement function, duration of > 900 milliseconds for counting + 40 times of change. | ||||
General technical indicators | |||||
The highest voltage between any terminal and earthing | 1000 V dc or ac RMS | ||||
Ω A input fuse protection | 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only | ||||
Display (LCD) | Update rate | 4 / SEC. | |||
The volt, ampere, ohm | 6000 times | ||||
frequency | 10000 times | ||||
capacitance | 1000 times | ||||
The battery type | Three AA alkaline batteries, NEDA IEC LR6 15 a | ||||
Battery life | At least 250 hours | ||||
Radio frequency communication | The 2.4 GHZ ISM band | ||||
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters | |||
, gypsum board wall | As far as 6.5 m | ||||
Wall, concrete, or steel electric shell | As far as 3.5 m | ||||
The temperature | Working temperature | - 10 ° C to 50 ° C | |||
Storage temperature | To 40 ° to 60 ° C C | ||||
The temperature coefficient of | 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C) | ||||
Relative humidity | From 0% to 90% (0 ° C and 35 ° C) From 0% to 75% (35 ° C to 40 ° C) From 0% to 45% (40 ° C to 50 ° C) |
||||
At an altitude of | Work at an altitude of | 2000 m | |||
Stored at an altitude of | 12000 m | ||||
Electromagnetic compatibility EMI and RFI, EMC (EMC) and RF |
EN 61326-1:6, EN 61326-2 - "06 ETSI V1.7.1 EN 300, 328:2006, ETSI EN 300 489 V1.8.1:2008 The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE |
||||
Meet safety standards | The ANSI/ISA 61010-1 / (82.02.01) : 3rd edition CAN/CSA C22.2 No. 61010-1-12:3rd edition UL 61010-1:3 IEC/EN61010-1:10 |
||||
certification | CSA, the FCC, CE | ||||
Protection (IP) rating | IP54 | ||||
Pollution levels | 2 | ||||
Size (height x width x length) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||||
The weight of the | 340 g (12 oz) | ||||
Warranty period | Three years, | ||||
Is雷竞技app not compatible with Fluke CNX testing tools |
雷竞技appCurrent clamp module Fluke a3000 FC wireless communication
Technical indicators | ||
range | 0.5 A and 400.0 A | |
The resolution of the | 0.1 A | |
precision | 400.0 A: 2% + / - 5 (10 Hz to 100 Hz), of 2.5% plus or minus five (100 Hz - 500 Hz) | |
The surge current | According to the biggest readings | 999.9 A |
Crest factor (50 Hz / 60 Hz) | 3 (500 A) 2.5 (600 A) 1.42 (1000 A) C.F. > 2 increased by 2% |
|
LCD with backlight | 3 1/2 level a | |
Data storage rate/intervals | 1 second (minimum)/can be adjusted by the PC | |
The battery type | 15 A, 2 AA, NEDA IEC LR6 | |
Battery life | 400 hours | |
memory | Can record up to 65000 readings | |
Radio frequency communication | The 2.4 GHZ ISM band | |
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters |
, gypsum board wall | As far as 6.5 m | |
Wall, concrete, or steel electric shell | As far as 3.5 m | |
Working temperature | - 10 ° C to + 50 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
The temperature coefficient of | Increased by 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C) | |
Working humidity | 35 ° C in 90% 40 ° C in 75% 50 ° C in 45% |
|
At an altitude of | Work at an altitude of | 2000 m |
Stored at an altitude of | 12000 m | |
Electromagnetic compatibility (EMC) | EN 61326-1:6 | |
Meet safety standards | IEC 61010-1600 - V class III, third edition pollution level 2 | |
Security level | The CAT III 600 V | |
certification | CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE | |
Protection (IP) rating | IP30 | |
Pollution levels | 2 | |
Jaw opening | The 34 mm (1.33 in) | |
Size (high x width x deep) | 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in) | |
The weight of the | 0.22 kg (8 oz.) | |
Warranty period | Three years, | |
Is雷竞技app not compatible with Fluke CNX testing tools |
雷竞技appFluke t3000 FC wireless module type K temperature
General technical indicators | ||||
The range of K type | - 200 ° C to 1372 ° C | |||
The resolution of the | 0.1 ° c. | |||
precision | + / 0.5% + 0.3 ° C | |||
The input terminals | K type miniature | |||
W/LCD backlight | 3 1/2 level a | |||
Data storage rate/intervals | 1 second (minimum)/can be adjusted by the PC | |||
The battery type | 15 A, 2 AA, NEDA IEC LR6 | |||
Battery life | 400 hours | |||
memory | Can record up to 65000 readings | |||
Radio frequency communication | The 2.4 GHZ ISM band | |||
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters | ||
, gypsum board wall | As far as 6.5 m | |||
Wall, concrete, or steel electric shell | As far as 3.5 m | |||
Working temperature | - 10 ° C to + 50 ° C | |||
Storage temperature | To 40 ° C to + 60 ° C | |||
The temperature coefficient of | Reading of 0.01% + 0.03 ° C (° C) | |||
Temperature scale | ITS - 90. | |||
Working humidity | 35 ° C under 90%, 40 ° C under 45%, 50 ° C under 75% | |||
At an altitude of | Work at an altitude of | 2000 m | ||
Stored at an altitude of | 12000 m | |||
Electromagnetic compatibility (EMC) | EN 61326-1:6 | |||
Meet safety standards | IEC 61010-1, in class I, third edition pollution level 2 | |||
certification | CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE | |||
Protection (IP) rating | IP42 | |||
Pollution levels | 2 | |||
Size (high x width x deep) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
The weight of the | 0.22 kg (8 oz.) | |||
Warranty period | Three years, | |||
Is雷竞技app not compatible with Fluke CNX testing tools |
Mode雷竞技appl: Fluke 3000 FC HVAC systems
Include:
- 雷竞技appFluke 3000 FC series wireless multimeter
- 雷竞技appFluke a 3000 FC wireless college ac current clamp module
- 雷竞技appFluke 3000 t thermocouple thermometer
- TL175 test conductor
- AC175 alligator clip
- 80 pk - 1 bead K type thermocouple
- Magnetic hanging belt
Manual + 雷竞技appresources: Fluke 3000 FC HVAC systems
- 3000 FC | user manual
- 3000 FC | quick reference guide
- 3000 FC | calibration manual
- 3000 FC | calibration manual addendum
- 3000 FC statement | non-volatile memory
- The a3000 FC | calibration manual
- The a3000 FC | quick reference guide
- A3001 FC | calibration manual
- A3001 FC | quick reference guide
- A3002 FC | calibration manual
- A3002 FC | quick reference guide
- 雷竞技appFluke Connect | quick reference guide
- 雷竞技appFluke Connect wi-fi to Thermal Imager | quick reference guide
- Ir3000 FC | quick reference guide
- PC 3000 FC | instructions page
- T3000 FC | quick reference guide
- T3000 FC | calibration manual
- V3000 FC | calibration manual
- V3000 FC v3001 FC | quick reference guide
- V3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC statement | non-volatile memory
- 雷竞技appFluke Connect video is introduced: using TrendIt chart function identification of intermittent fault
- 雷竞技appFluke Connect video introduction: how to save measurements to EquipmentLog history
- 雷竞技appFluke Connect video introduction: how to create equipment through EquipmentLog history function benchmark
- 雷竞技appFluke Connect to perform predictive maintenance
- Us雷竞技appe Fluke Connect the application from a safe distance measurement
- Using ShareLive video sharing real-time measurements and video call function
- How 雷竞技appto use the Fluke Connect application sharing equipment measurements
- How to record the measured value and draw diagrams
- Records automatically by the AutoRecord measurement function measurements
- Th雷竞技apprough the Fluke Connect Connect multiple tools at the same time