雷竞技appFluke 80 series V digital multimeter
The main features
- Able to accurately measure speed motor drive and other electrical equipment noise voltage and frequency (87 v/C)
- Built-in thermometer, without other equipment, can easily read the temperature (87 v/C)
- Optional magnetic suspension kits, convenient setting and observation, hands free to engage in other jobs
- High brightness of the large digital display screen has two levels of backlight, making 80 V series multimeter measurement results are easier to read than other models
Produc雷竞技appts overview: Fluke 80 series V digital multimeter
Accuracy and diagnostic function can make industrial productivity
New 雷竞技appFluke 87 v/C greatly improve the functions of measurement, diagnosis, resolution and accuracy, able to solve more motor drive, factory automation, power distribution equipment and electrical and mechanical equipment failure.
The new 80 series DMMS include the following models:
- 雷竞技appFluke 83 V industrial DMMS
- 雷竞技appTrue RMS Fluke 87 v/C industrial DMMS
- 雷竞技appFluke 87 v/E2 industrial electrician suite
87 v/C DMMS are very similar to the classic 87 DMMS, but has a stronger ability to solve problems, more secure, convenient and has better impact protection.
80 v series multi-purpose table through a third party independent testing, fully meet the ANSI/ISA S82.01 second edition and CAT EN61010-1 1000 v, 600 v/CAT III IV standard requirements.Can withstand more than 8000 V voltage pulse, which greatly reduces the danger of surge and breakdown.
function | 83 v | 87 v |
Accurately measure true RMS ac voltage and current of nonlinear signal | • | |
Optional filter, used to accurately measure the voltage and frequency of the motor drive | • | |
Dc accuracy of 0.05% | • | |
6000 words, 3-3/4 | • | • |
4-1/2 a precise measurement mode (20000 words) | • | |
Measure up to 1000 V ac and dc signals | • | • |
Continuous measurement for 30 seconds, 20 A, 10 A current | • | • |
The built-in thermometer, do not need to carry more tools (including the TC probe) | • | |
Up to 200 kHz frequency measurement, as well as the percentage of duty ratio | • | • |
Impedance, on-off and diode testing | • | • |
10000 (including F capacitance measurement range for capacitance measurement devices and motors | • | • |
Minimum/maximum - average record, with minimum/maximum alarm functions, can automatically capture signal changes | • | • |
Peak capture capabilities, can record up to 250 mu s transient signals | • | • |
Relative mode, when making low impedance measurements can eliminate the interference of the test lead | • | • |
Automatic and manual range, with greater flexibility | • | • |
Contact function, capture stable readings, eliminate the noise signal | • | • |
Large Numbers and two-stage white backlight, enhance the readability | • | • |
Used in the simulation of the rapid change or unstable signal display pointer | • | • |
Input alarm function, when using the wrong input plug sound alarm | • | • |
Improvement of optional sleep mode, extend battery life | • | • |
To quickly without the need for calibration of seal, replace the battery | • | • |
With a removable holster "classic" design, a holster can hold the test wire and probe | • | • |
A lifetime warranty | • | • |
Electrical safety
All the input level of protection for the Category III, 1000 V and 600 V Category IV.Can take the pulse of more than 8000 V, which greatly reduces the danger of surge and breakdown.
Correct PWM motor drive signal measurement
Before this, no one multi-purpose table can accurately measure speed signal of the motor.How雷竞技appever, Fluke 87 v/C specifically for complex signal generated by the adjustable speed motor drive design.No need to guess driving system fault, will obtain the potential productivity.Each and every measurement is accurate.
- Pulse width modulation (PWM) ac voltage precise measurement with noise.Can be measured on the ASD and the motor terminal.
- Accurate measurement frequency (motor speed).frequency测量不受ASD负载频率的影响
- Using the optional current clamp attachment, alternating current can be measured
- 87 v/C reading compared with ASD the value shown on
- Special shielding measures to prevent the drive systems of high frequency, the effects of high-energy noise
Produc雷竞技appt specifications: Fluke 80 series V digital multimeter
Technical indicators | ||
Dc voltage | Maximum voltage | 1000 V |
precision | Plus or minus 0.1% (+ 1) | |
Maximum resolution | Including 100 V | |
Ac voltage | Maximum voltage | 1000 V |
precision | Plus or minus 0.5% (+ 2) | |
Maximum resolution | 0.1 mV | |
Dc current | Maximum current | 10 A (20. A, the longest 30 seconds) |
Accuracy of current | Plus or minus 0.4% (+ 2) | |
Maximum resolution | 0.01 mA | |
Alternating current | Maximum current | 10 A (20. A, the longest 30 seconds) |
Accuracy of current | Plus or minus 1.2% (+ 2) | |
Maximum resolution | 0.1 (including A | |
resistance | The biggest resistance | 50 M Ω |
precision | Plus or minus 0.4% (+ 1) | |
Maximum resolution | 0.1 Ω | |
capacitance | The largest capacity | 9999 (including F |
precision | Plus or minus 1% (+ 2) | |
Maximum resolution | 0.01 the nF | |
frequency | Maximum frequency | 200 kHz |
precision | Plus or minus 0.005% (+ 1) | |
Maximum resolution | 0.01 Hz | |
Duty ratio | The biggest duty ratio | 99.9% |
precision | Plus or minus (+ 0.1% / 0.2% kHz) | |
Maximum resolution | 0.1% | |
conductance | The biggest conductance | 60.00 nS |
precision | Plus or minus 1.0% (+ 10) | |
Maximum resolution | 0.01 nS | |
diode | range | 3 V |
The resolution of the | 1 mV | |
precision | Plus or minus 2% (+ 1) | |
Duty ratio range | The accuracy of | Within the scope of plus or minus (+ 0.1% / 0.2% kHz) |
Environmental indicators | ||
Working temperature | - 20 ° C to + 55 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
Humidity (no condensation) | 0% - 90% (0 ° C - 35 ° C) 0% - 70% (35 ° C - 55 ° C) |
|
Work at an altitude of | 2000 m | |
Safety specifications | ||
The overvoltage category | EN 61010-1 to 1000 V, the CAT CAT III IV 600 V | |
approval | CSA and TUV | |
The mechanical and general specifications | ||
display | digital | 6000 count, updated four times per second |
simulation | 32, update 40 times per second | |
frequency | When counting, 19999 > 10 Hz update 3 times per second | |
size | 201 x 98 x 52 mm (with holster) | |
The weight of the | 355 g | |
Weight (with holster and flexible frame) | 624 g | |
Warranty period | A lifetime | |
Battery life | Alkaline batteries are usually ~ 400 hours, no backlight | |
impact | 1 m high in the fall (according to IEC 61010-1:01) | |
vibration | According to the MIL - PRF - 28800 specification for level 2 meter |
Mode雷竞技appl: Fluke 80 series V digital multimeter
Include:
- TL75 test line
- AC175 alligator clip
- Protective sleeve
- 9 v battery (installed)
Manual + 雷竞技appresources: Fluke 80 series V digital multimeter
- Series 80 V | user manual
- Series 80 V | user manual addendum
- Series 80 V | primer
- Series 80 V | portal addendum
- Series 80 V | calibration manual
- Series 80 V | calibration manual addendum
- Series 80 V | safety guidelines
- Series 80 V, 83 V, 85 V, 87 V | quick reference guide
- 83, 87, 88 Series V | non-volatile memory
- 88 V | quick reference guide