FC wireless v3003 ac - dc voltage measurement kit

  • 雷竞技appFluke v3003 FC Wireless AC - DC Voltage Measurement Kit
  • 雷竞技appFluke 3000 FC Series Wireless Multimeter
  • 雷竞技appFluke 805 FC Vibration Meter
  • 雷竞技appFluke 3000 FC Series Wireless Multimeter

The main features

FC wireless v3003 ac - dc voltage measurement kit

Wit雷竞技apph a Fluke Connect ® application of Fluke 3000 FC series wireless multimeter can meet the needs of the convenient test and measurement troubleshooting.

  • Ac and dc voltage 1000 V
  • Ac and dc current is 0.01 mA resolution
  • Connectivity, resistance, diode testing, capacitance and frequency measurement
  • Minimum/maximum record
  • The CAT III 1000 V, the CAT IV 600 V;IP54

Wit雷竞技apph the help of a Fluke v3000 FC ac voltage module, you can:

  • To measure true RMS ac 1000 V
  • It is used as instrument independently or as part of the system
  • Using the record function, can record and save as many as 65000 readings

雷竞技appFluke v3001 FC dc voltage module enables you to:

  • Measured 1000 V direct current
  • It is used as instrument independently or as part of the system
  • Using the record function, can record and save as many as 65000 readings

Products overview: FC wireless v3003 ac - dc voltage measurement kit

FC wireless v3003 ac - dc雷竞技app voltage measurement suite is a Fluke Connect wireless test tools part of the product line

Will v3000 FC wireless communication module and a voltage v3001 FC wireless module is connected to the dc voltage is your test points, and wireless digital multimeter in 3000 FC on the results of the scope of view as far as 20 meters.

You'll save time, without resistance.the collect multiple measurements.The three-phase system is measur雷竞技apped using multiple modules, can be used as independent measurement tools, or with other Fluke Connect ™ frequent testing module combined into a system.

In short, you can even check module reading through closed electrical panel.In addition, no manual record data, because the FC wireless voltage module using the optional PC adapter can capture as many as 65000 group has the minimum/maximum average reading/timestamp.雷竞技appFluke Connect wireless test tool also by you in the position of the separation of the test point view reading, to improve safety.

Now, you can get in the operation of the reading on the machinery and equipment, only there is a damage risk measurement module.

Product specifications: FC wireless v3003 ac - dc voltage measurement kit

雷竞技appFluke 3000 FC wireless digital multimeter

* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).

DC to 60 Hz
Detailed technical indicators
Ac voltage
Range creates The resolution of the Precision squared after4 Precision squared after4
45 Hz - 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0% + 3 2.0% + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
1. All ac voltage range has been designated as the range of 1% to 100%.
2. The full scale highest do not exceed 500 V the crest factor of 3 or less, at 1000 V linear low crest factor < 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading).
4. Do not over 107 V - Hz.
Dc voltage, connectivity, resistance, diode test and capacitance
function range The resolution of the The accuracy of
The mV 600.0 mV 0.1 mV 0.09% + 2
V 6.000 V 0.001 V 0.09% + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15% + 2
Ω 600 Ω 1 Ω < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit.
Ω 600.0 Ω 0.1 Ω 0.5% + 2
6.000 k Ω 0.001 k Ω 0.5% + 1
60.00 k Ω 0.01 k Ω
60.00 k Ω 0.1 k Ω
600.0 k Ω 0.001 M Ω
50.00 M Ω 0.01 M Ω 1.5% + 3
Diode test 2.000 V 0.001 V 1% + 2
Including F 1000 nF 1 nF 1.2% + 2
10.00 u F 0.01 u F
100.0 u F 0.1 u F
9999 mu F creates 1 u F 10% of the typical
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2.
Ac and dc current
function Range creates The resolution of the The accuracy of
MA communication
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5% + 3
400.0 mA after 0.1 mA
MA DC squared 60.00 mA 0.01 mA 0.5% + 3
400.0 mA after 0.1 mA
1. All alternating current range has designated range of 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.
frequency
range The resolution of the Precision creates
99.99 Hz 0.01 Hz 0.1% + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz.
The input features
function overload
To protect the
The input impedance
(nominal value)
Common mode rejection ratio (1 k Ω non-equilibrium) Norm inhibition
1100 Vrms > 10 M Ω < 100 pF In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB At 50 Hz or 60 Hz greater than 60 dB
1100 Vrms > 10 M Ω < 100 pF > 60 dB
1100 Vrms > 10 M Ω < 100 pF In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB At 50 Hz or 60 Hz greater than 60 dB
Open circuit voltage Full scale voltage Typical short-circuit current
To 6 M Ω 50 M Ω
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA,
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
MA function
Overload protection 44/100 fuse, A, 1000 V, fuse
overload 600 mA overload for up to 2 minutes, at least 10 minutes to a halt
Minimum/maximum record accuracy
Dc function Specify the precision of the measurement function, duration of > 350 milliseconds for counting + 12 times of change.
Communication function Specify the precision of the measurement function, duration of > 900 milliseconds for counting + 40 times of change.
General technical indicators
The highest voltage between any terminal and earthing 1000 V dc or ac RMS
Ω A input fuse protection 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only
Display (LCD) Update rate 4 / SEC.
The volt, ampere, ohm 6000 times
frequency 10000 times
capacitance 1000 times
The battery type Three AA alkaline batteries, NEDA IEC LR6 15 a
Battery life At least 250 hours
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
The temperature Working temperature - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
The temperature coefficient of 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C)
From 0% to 75% (35 ° C to 40 ° C)
From 0% to 45% (40 ° C to 50 ° C)
At an altitude of Work at an altitude of 2000 m
Stored at an altitude of 12000 m
Electromagnetic compatibility
EMI and RFI, EMC (EMC) and RF
EN 61326-1:6, EN 61326-2 - "06
ETSI V1.7.1 EN 300, 328:2006, ETSI EN 300 489
V1.8.1:2008, the FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements
FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE
Meet safety standards The ANSI/ISA 61010-1 / (82.02.01) The third edition
CAN/CSA C22.2 No. 61010-1-12 The third edition
UL 61010-1 The third edition
IEC/EN 61010-1 2010
certification CSA, the FCC, CE
Protection (IP) rating IP54
Pollution levels 2
Size (height x width x length) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
The weight of the 340 g (12 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appFluke v3000 FC wireless ac voltage module

Precision is specified for plus or minus (% [reading] + [the least significant digit]).All the range for the transformation.
Precision is specified as the transform of the range of 5% to 100%, 18 ° C to 28 ° C.

Technical specifications
Range creates/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Precision squared after4 45 Hz - 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All ac voltage range has been designated as the range of 1% to 100%.
2. The full scale highest do not exceed 500 V the crest factor of 3 or less, at 1000 V linear low crest factor < 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading).
4. Do not over 107 V - Hz.
General technical indicators
LCD with backlight 3 1/2 level figures, 6000 times, update 4 per second
The battery type 15 A, 2 AA, NEDA IEC LR6
Battery life 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Working humidity 35 ° C under 90%, 40 ° C under 45%, 50 ° C under 45%
At an altitude of Work at an altitude of 2000 m
Stored at an altitude of 12000 m
Electromagnetic compatibility (EMC) EN 61326-1:6
Meet safety standards The ANSI/ISA 61010-1 / (82.02.01) The third edition
CAN/CSA C22.2 No. 61010-1-12 The third edition
UL 61010-1 The third edition
IEC/EN 61010-1 2010
Security level The CAT IV III 1000 V 600 V, the CAT
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP42
Pollution levels 2
Size (high x width x deep) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
The weight of the 0.22 kg (8 oz.)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appDc voltage Fluke v3001 FC wireless module

Within one year after the calibration precision, working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).All the range for the transformation.precision指定为由自动量程获得的量程,18 °C 至 28 °C。

Voltage specification
function
mVDC Range creates/resolution 600.0 mV / 0.1 mV
precision 0.09% + 3
VDC Range creates/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
precision 0.09% + 3
Range creates/resolution 1000 V / 1 V
precision 0.15% + 2
General technical indicators
LCD with backlight 3 1/2 level, 6000 number, update rate of four per second
The battery type 2 AA alkaline batteries, NEDA IEC LR6 15 a
Data storage rate/intervals Can be adjusted by the PC for 1 second to 1 hour, the default value is 1 minute
Battery life At least 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHz ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C), 0% to 75% (35 ° C to 40 ° C).
From 0% to 45% (40 ° C to 50 ° C)
Electromagnetic compatibility (EMC) IEC 61236-1: portable
Meet safety standards IEC 61010-1600 - V IV class / 1000 V class III, third edition, pollution level 2
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP42
Size (high x width x deep) 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
The weight of the 0.255 kg (9 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

Model: FC wireless v3003 ac - dc voltage measurement kit

FLK - v3003 FC Kit
FC wireless v3003 ac - dc voltage measurement kit
  • 雷竞技appFluke 3000 FC series wireless multimeter
  • 雷竞技appFluke v3000 ac voltage module
  • 雷竞技appFluke v3001 dc voltage module
  • TL175 test conductor
  • TL224 test conductor
  • TL222 test conductor
  • AC175 alligator clip
  • AC285 alligator clip
  • AC220 alligator clip
  • Magnetic hanging belt

Manual + resource: FC wireless v3003 ac - dc voltage measurement kit