雷竞技appFluke T5-600 voltage electrical current tester is | voltage fluctuation
The main features
- Reliable electrical tester, can automatically measure the ac voltage and dc voltage, high accuracy digital resolution
- Provide a simple and accurate OpenJaw ™ current measurements
- Shows the highest 1000 Ω resistance
- Is on and off the buzzer, achieve rapid pass/reject test
- All the security level of input for CAT III EN61010-1 600 V.UL, CSA certification
Produc雷竞技appts overview: Fluke T5-600 voltage electrical current tester is | voltage fluctuation
- T5-600 voltage electrical current breaking tester is a multifunctional failure diagnosis and elimination of tools, suitable for up to 600 V.Compact, small tools, can be used to check the voltage, on and off, and current.Simply select voltage, resistance and current, the remaining work by the tester is completed.Use its OpenJaw ™ current measurement function without disconnect circuit, can measure current of up to 100 A.
Separable SlimReach ™ test probes, specifically for local national electrical standard and custom.In addition, its strong testing line support a variety of options, such as current clamp and special probe.The test line可整齐地收纳于测试仪背面的卡槽中,便于储存在工具袋中随身携带。增加H5保护套选件,可将T5-1000夹在皮带上。对于更高电压的应用,请选择Fluke T5-1000。
Other useful features: - Compact design, convenient store probe
- Affordable 3 m (10 ft.).
- Separable SlimReach ™ test probes, specifically for local national electrical standard and custom
- Distance is longer than the solenoid type tester connection
- Provides automatic shutdown mode, extend battery life
- Can receive to case option, and hang it on the belt, and can neatly to receive a test line
Produc雷竞技appt specifications: Fluke T5-600 voltage electrical current tester is | voltage fluctuation
Technical indicators | ||
Jaw size | 12.9 mm (0.5 in) | |
The biggest cable size | 1/0 THHN cable | |
Ac RMS current range | 0 to 100.0 A | |
Alternating current accuracy (50/60 Hz) | 3% plus or minus 3 | |
Ac response | On average, | |
Ac/dc voltage range | 0 to 600 V | |
Voltage accuracy | communication | 1.5% plus or minus 2 words |
dc | 1% plus or minus 1 word | |
The resistance range | 0 to 1000 Ω | |
On and off sex hum threshold | Open @ < 25 Ω;Close @ 400 Ω > | |
The threshold voltage indicator LED | To ensure that the light when ac 30 V | |
Environmental indicators | ||
Working temperature | - 10 ° C to 50 ° C | |
Storage temperature | - 30 ° to 60 ° C C | |
No condensation (humidity) | Between 0% and 95% (5 ° to 30 ° C C); From 0% to 75% (30 ° C to 40 ° C). From 0% to 45% (40 ° C to 50 ° C) |
|
Dust/water | is | |
Work at an altitude of | Up to 2000 meters | |
The temperature coefficient of | Accuracy of 0.1 x (rules) / ° C (18 ° C or > < 28 ° C) | |
Safety indicators | ||
Security level | IEC 61010-2-032, IEC61010-2-033: the CAT III 600 V, 100 A ac | |
Accredited institution | CSA and TUV | |
The highest voltage | Arbitrary terminals and ground between the maximum voltage of 600 V | |
Machinery and general technical indicators | ||
size | 51 x 30.5 x 203 mm | |
The weight of the | 300 g | |
The quality assurance | 2 years | |
Battery life | 200 hours, when using zinc chloride battery;400 hours, the use of alkaline batteries | |
The battery type | Type 2 AA batteries | |
Low battery indication | is | |
Current clamp opening size: | The 12.9 mm | |
Calibration cycle | 1 year | |
The test line | type | Big load, flexible cable, the rated voltage of 1000 V. |
Field replaceable cable terminal, use the belt sheathed banana plug male head | ||
The probe | One red, one black | |
Separate Slim - Reach ™ probe tip | ||
type | TP1 Slim Reach ™ test probe |
Mode雷竞技appls: Fluke T5-600 voltage electrical current tester is | voltage fluctuation
雷竞技appFluke T5-600
600 v voltage, on and off, and current test agent
Includes:
- 600 V Voltage, continuity and current tester
- 4 mm detachable the probes
- Instruction sheet