雷竞技appFluke 43 b power quality analyzer
Has been discontinued
The main features
harmonic
- Harmonic voltage, current and power
- Up to 51 times harmonic
- Total harmonic distortion (THD)
- The phase Angle of each harmonic
power
- Watt, power factor and displacement power factor, volt-ampere and spent
- Voltage and current waveform
three-phase
- Screen graphics to guide the user how to set up three phase power measurement
Sag and surge
- After 16 days of time, one by one cycle to continuous measurement of voltage and current
- Using the cursor read sag and shot up the time and date
The transient phenomena
- Capture voltage transients and waveform distortion
- Capture and save as many as 40 transient events
- Displays the time and date associated with transient
Voltage/amp/hz
- Voltage and current waveform
- True RMS voltage and current
- frequency
This product has been discontinued or reclassified
Produc雷竞技appts overview: Fluke 43 b power quality analyzer
Fully grasp the power quality
Produc雷竞技appt specifications: Fluke 43 b power quality analyzer
Technical specifications | |||
The input parameters | The input impedance | 1 M Ω, 20 pF | |
The rated voltage | 600 V RMS, CAT III | ||
V/A/Hz | True RMS voltage (ac + dc) |
range | 5.000 V, 50.00 V, 500.0 V, 1250 V creates |
precision | Plus or minus 1% (+ 10 counts) | ||
True RMS current (ac + dc) |
range | 50.00 A, 500.0 A, 5.000 kA, 50.00 kA, 1250 kA | |
precision | Plus or minus 1% (+ 10 counts) | ||
frequency | range | 10.0 to 15.0 kHz | |
precision | Plus or minus (reading [%] + [count number]) : 0.5% + 2 | ||
CF crest factor | range | 1.0-10.0 | |
precision | (5% + 1 count) | ||
Power display | Watt, VA, VAR | Single-phase and three-phase three-wire balance load | |
range | 250 W to 1.56 GW | ||
precision | Plus or minus 4% (+ 4 count) fundamental wave power | ||
precision | Plus or minus 2% (+ 6) total power | ||
PF (power factor) | range | 0-1.0 | |
precision | + / - 0.04 | ||
DPF (displacement power factor) | range | 0.25-0.9 | |
precision | + / - 0.04 | ||
range | 0.90-1.0 | ||
precision | + / - 0.03 | ||
The H2 base wave frequency | range | 40.0 to 70.0 Hz | |
precision | Plus or minus (reading [%] + [count number]) : 0.5% + 2 | ||
Harmonic display | Voltage, current and frequency | range | Fundamental to 51 harmonics |
precision | VA + + 2 count (3%) W + + 2 count (5%) | ||
Fundamental wave | 2 to 31 harmonics | VA - counting (5% + 3) W + + 10 counts (10%) | |
32 to 51 times harmonic | Plus or minus 15% (+ 5) to W + (30% + 5 count) | ||
The fundamental frequency | range | 40 Hz - 70 Hz | |
precision | + / - 0.25 Hz | ||
phase | range | V, A (fundamental harmonic) | |
precision | Plus or minus 3 ° to plus or minus 15 ° | ||
range | W (voltage wave of current harmonic) | ||
precision | Plus or minus 5 ° to plus or minus 15 ° | ||
K coefficient (current and power) |
range | 1.0 to 30.0 | |
precision | Plus or minus 10% | ||
THD (total harmonic distortion) | range | 0.00-99.99 | |
precision | Counting + + 8 (3%) | ||
Drop and litres | Recording time | 4 minutes to 16 days (optional) | |
Actual Vrms, maximum Vrms, minimum (AC + DC) | range | 5.000 V, 50.00 V, 500.0 V, 1250 V creates | |
precision | Reading + + 10 counts (2%);The cursor readout±(2% + 12 个计数) | ||
Actually very different, very different, the largest minimum (AC + DC) | range | 50.00 A, 500.0 A, 5.000 kA, 50.00 kA | |
precision | Plus or minus 2% (+ 10 counts) | ||
Transient capture | The minimum pulse width | 40 ns | |
Enter 1 useful bandwidth | Dc to 1 MHz | ||
The number of transient events | 40 | ||
Voltage threshold Settings | Refer to above or below 20%, 50%, 100%, 200% | ||
Reference signal | After the START (START) button, measuring the Vrms and frequency of the signal.According to these data, calculation of pure sine wave as a reference threshold Settings. | ||
The cursor Vpeak minimum, Vpeak maximum | 10 V, 25 V, 50 V, 125 V, 250 V, 500 V, 1250 V accuracy: + / - 5% of full scale | ||
R, C, diode, on and off | The resistance range | 500.0 Ω Ω Ω, 5.000 k, 50.00 k, 500.0 k Ω Ω, 5.000 M, 30.00 M Ω | |
Precision of resistance | Counting 0.6% plus or minus (+ 5) | ||
Capacitance range | NF, 500.0 the nF, 5.000 50.00 mu, 50.00 mu, 500.0 mu F F F | ||
Capacitance accuracy | Plus or minus 2% (+ 10 counts) | ||
Diode range | 0 to 3.000 V | ||
Diode voltage | |||
precision | Counting 2% plus or minus (+ 5) | ||
On and off sex | Buzzer open < 30 Ω + 5 Ω | ||
Maximum current | 0.5 mA | ||
The temperature | ° C or ° F | ||
The surge current | Surge time | 1 second, 5 seconds, 10 seconds, 50 seconds, 100 seconds, 5 minutes | |
Current range | 1 A, 5 A, 10 A, 50 A, 100 A, 500 A, 1000 A | ||
The cursor readout | The cursor to the maximum peak 1 and 2 | ||
precision | Plus or minus 5% of full scale | ||
Two cursor interval of time | Four to 235 pixels (= 1 pixel surge time / 250) accuracy: + / - 0.2% (+ 2 pixels) | ||
The temperature (including accessories) |
range | - 100 ° C to 400 ° C | |
precision | Counting 0.5% plus or minus (+ 5) | ||
Oscilloscope display | measurement | Dc, ac, ac + dc - peak, peak, peak, frequency, duty cycle, phase, pulse width, crest factor | |
Time range | 20 ns/div and 60 s/div | ||
Maximum sampling rate | 25 MS/s | ||
bandwidth | Voltage channel [1] | 20 MHz (in the input), 1 MHz (use TL24 test line) | |
Current channel [2] | Dc to 15 kHz (in the input point), 10 kHz (using i400s current clamp) | ||
coupling | Ac and dc (10 Hz - 3 dB) | ||
Vertical sensitivity | 500 v / 5 mV/frames | ||
Vertical resolution | 8 bit (256) | ||
Record length | 512 sampling points/channel | ||
Time base scope | 60 S/div to 20 nS/div + + 1 pixel (0.4%) | ||
When the base model | Normal, rolling, single | ||
Pre trigger | The ten biggest grid | ||
Trigger source | Type 1, type 2 or automatic selection | ||
Trigger mode | Automatic touch namely test (Connect - and - View ™), Free Run and a single trigger | ||
Connect - and - view ™ | Through advanced automatic pattern recognition signal trigger | ||
Automatically adjust the trigger, and amplitude, stable waveform display |
|||
memory | 20 (for screen, setting, data) | ||
record | Recording time | 4 minutes to 16 days (optional) | |
parameter | Choose from the following parameter set one or two parameters | ||
Voltage/current/frequency |
|||
power | Watt, VA, VAR, PF, DPF, frequency | ||
Harmonic and THD, voltage (fundamental wave and harmonic), ampere (fundamental wave and harmonic), w (fundamental wave and harmonic) |
|||
Frequency (harmonic), accounting for % of the total (harmonic), phase (harmonic), the K factor |
|||
The temperature | |||
resistance | Resistor, diode, on and off, capacitance | ||
oscillographic | Dc voltage, dc current, ac voltage and ac current, frequency, | ||
Pulse width, phase positive or negative, positive or negative pulse rate, minimum, maximum peak peak, peak, crest factor (minimum - largest) |
|||
Environment specification | Working temperature | 0 ° C to + 50 ° C | |
Safety specifications | Electrical safety | EN 61010-1 CAT III, 600 v by CSA certification | |
Machinery and general technical specifications | size | 232 x 115 x 50 mm | |
The weight of the | 1.1 kg | ||
Warranty period | 3 years | ||
Battery life | Rechargeable nickel cadmium battery pack (including battery charger), 6.5 hours longer running time (work) | ||
Shock and vibration | MIL 28800 e, 3 class III, B type | ||
The portable box | IP51 (dustproof, waterproof, resistance to fall) | ||
1. The security level for EN 61010-1 600 V CAT III CSA |
Mode雷竞技appl: Fluke 43 b power quality analyzer
雷竞技appFluke 43 b
雷竞技appFluke 43 b Single Phase Power Quality Analyzer
雷竞技appFluke 43 b includes:
- C120 scale instrument box
- TP1 flat Slim - Reach ™ test probe
- TP4 4 mm round head Slim - Reach ™ Test the Probes
- I400S alternating current clamp
- PM - 9080 optical isolation RS232 interface adapter
- BP120 rechargeable nickel cadmium battery (installed)
- PM - 8907 power adapter/battery charger
- SW43W 雷竞技appFluke View ™ power quality analysis software and cd-rom version of the user manual
- Shielding the banana plug adapter to the BNC
- User manual/application guide