Fluke insulation wire clamp
The main features
- Voltage level of 1000 V 8 inches big Lineman forceps
- Through the sharp line indented clamping hole tightly clamping jaw and 4 PM
- Exterior long, easy to cut wires in the narrow space
- After AC 1000 V and 1500 V DC voltage of the certification
- Wrench, 20% lighter than the other design
- By the German CMV steel forging
Products overview: fluke insulation wire clamp
Wire to cut.Cable need to be stretched.Plunger to distortion.Sometimes, need fixed.A fluke insulation wire clamp and side cutting pliers, when tooth jaw need to bring in a work, you will have many choices.
Fluke Lineman combination pliers exterior insulation of long, easy to cut wires in the narrow space.These pliers weight 20% lighter than the other design, but they can with sharp jagged clamping hole tightly clamping jaw and 4 PM.By the German chrome vanadium molybdenum (CMV) steel and enjoyLimited lifetime warranty.
Product specifications: fluke insulation wire clamp
Pliers type | Nominal length (inches) | Nominal length (mm) |
---|---|---|
Combination pliers | 8 | 200 |
The warranty period
Fluke insulation hand tools limited warranty for life
Each a fluke insulation hand tools are not material and process defects.The so-calle雷竞技appd "life" is refers to the Fluke here seven years after the termination of manufacturing this product, but the guarantee period should be at least 15 years from the date of the products to buy.This warranty does not apply to neglect, abuse, pollution, modified, accident or abnormal work or handling conditions lead to damage and the damage of the mechanical components or normal wear and tear.This warranty applies only to the original purchaser and shall not be transferred.
Fluke insulating the use of hand tools and runtime maintenance advice
The following is about the fluke insulation hand tools maintenance, inspection, test and use again.
Warning - in order to prevent electric shock or injured, please note that the following items:
- The finger grip behind the tool refers to protection device.Do not touch the conductive parts.
- Always wear approved eye protection equipment.
- Do not use in damp environment.Can only use tools to clean and dry condition.
- Don't you push hard on the tool insulating layer, or insulating layer may be damaged.For example, using the insulation surface as a fulcrum for leverage or wedge items, or use other tools such as forceps or wrench to clamping tool handles to increase torque insulated or leverage.
If it is not in accordance with the specified method using the product, protection function may fail.
store
Should be stored properly insulating hand tools to the insulating layer in the process of storage or transport damaged dropped to a lower risk.The insulation should be stored apart and other tools, hand tools to prevent mechanical damage or confused with the insulated tools.In addition, should be to prevent the overheating insulation hand tools contact surface (such as steam pipe) or by excessive ultraviolet radiation.
Check before use
Before use, the user should check each insulating the appearance of the hand tools.If there is any doubt on the safety of insulation of hand tools, shall conform to the qualifications of personnel for inspection.If you need, re-inspection will be required to determine the appropriate sex, or for disposal to avoid future use.
The temperature
Insulated hand tools can only be temperature - 20 ° C to + 70 ° C under the environment of use.Marked with "C" tool can only be temperature - 40 ° C to + 70 ° C under the environment of use.
Regular inspection and the reinspection do not coincide
Suggested by appropriately trained personnel check once a year the appearance, to determine the insulation can continue to use manual tools.If the national regulations for electrical recheck, or there is any doubt, after a visual inspection to the relevant dielectric insulation hand tools for IEC 60900 test.
Model: fluke insulation wire clamp
Insulated wire clamp