雷竞技appFluke 1503 insulation resistance tester
The main features
- Insulation testing range:
- Ω 0.1 M to 2000 M Ω
- Insulation test voltage:
- 500 V, 1000 V
- Remote testing probe is easy to repeat the test and test execution in inaccessible places
- Real-time circuit detection function is prohibited in the test the insulation voltage higher than 30 V, and raise the level of security
- Automatic release of capacitive voltage can better protect the safety of the user
- Ac/dc voltage: 0.1 V to 600 V
- Continuous current 200 mA
- Ω Ω resistance: 0.01 to 20.00 k
- Automatic shutdown function to save the battery
- Wide backlit display measurement results easy to read
- CAT 600 V overvoltage category IV level with the user's security level
- Each tester with remote probe, test line, probe and alligator clip
- Equipp雷竞技apped with optional Fluke TPAK magnetic suspension system enables you to to work in the other
- 4 AA alkaline batteries (NEDA 15 A or IEC LR6) can be at least 1000 times the insulation test
- One year warranty
Produc雷竞技appts overview: Fluke 1503 insulation resistance tester
雷竞技appFluke 1503 insulation tester is exquisitely meticulous, sturdy, and the operation is very convenient.Because can accept a variety of test voltage, they become ideal tool maintenance, debugging, and preventive maintenance.
These tools also equipped with a remote probe and other components, which makes the testing process is very fast, and saves cost.
More has the following official authorization Tmall stores, for you to choose a suitable way to purchase:
Insulation resistance meter the normal operation of the demonstration
Handheld bridge (resistance/capacitance/inductance tester) fluke ember LCR55A
Produc雷竞技appt specifications: Fluke 1503 insulation resistance tester
Ac/dc voltage measurement | |||||
precision | range | 600.0 V | |||
The resolution of the | 0.1 V | ||||
50 Hz - 400 Hz + (reading % + digits) | Plus or minus 2% (+ 3) | ||||
The input impedance | 3 M Ω (nominal), < 100 pF | ||||
Attenuation common-mode (1 k Ω imbalance) | When the dc > 60 dB, 50 or 60 Hz | ||||
Overload protection | The RMS or dc 600 V | ||||
Ground connection resistance measurements | |||||
The scope/resolution | 20.00 Ω | 0.01 Ω | |||
200.0 Ω | 0.1 Ω | ||||
2000 Ω | 1.0 Ω | ||||
20.00 k Ω | 0.01 k Ω | ||||
precision | Plus or minus 1.5% (+ 3) | ||||
Overload protection | 2 V RMS or dc | ||||
Open circuit voltage | > 4.0 V, < 8 V | ||||
Short circuit current | > 200.0 mA | ||||
The insulation specification | |||||
Measured value range | Ω 0.01 M to 2000 M Ω | ||||
The test voltage | 500 V, 1000 V | ||||
The test voltage accuracy | + 20% and - 0% | ||||
Short circuit current | 1 mA (nominal) | ||||
Automatic discharge | Discharge time < 0.5 seconds, C = 1 (including F or less | ||||
Electric circuit indicator | Before the initial test, if the terminal voltage > 30 V, inhibition test | ||||
The biggest capacitive loads | Under 1 (including F load operation | ||||
Accuracy of measurement | |||||
The output voltage | Display range | The resolution of the | Test current | precision + + (% readings for the lowest effective quantity) |
|
500 V (0% to + 20%) |
0.1 to 20.0 M Ω | 0.01 M Ω | 1 mA @ 500 k Ω |
Plus or minus 2.0% (+ 5) | |
20.0 to 200.0 M Ω | 0.1 M Ω | ||||
Between 200 and 500 M Ω | 1 M Ω | ||||
1000 V (0% to + 20%) | 0.1 to 200.0 M Ω | 0.1 M Ω | 1 mA @ 1 M Ω |
Plus or minus 2.0% (+ 5) | |
Between 200 and 2000 M Ω | 1 M Ω | ||||
General technical indicators | |||||
Applying to any of the maximum voltage terminal: | 600 V AC RMS or DC | ||||
Storage temperature | - 40 ° to 60 ° C - C (to 40 ° F to 140 ° F) | ||||
Working temperature | - 20 ° C to 55 ° C (4 ° F to 131 ° F) | ||||
The temperature coefficient of | 28 ° C temperature 18 ° C < or > (< > 64 ° F or 82 ° F), 0.05 x (specified accuracy) / ° C | ||||
Relative humidity | |||||
10 ° to 30 ° C C (50 ° F to 86 ° F), 0% to 95% | |||||
30 ° C to 40 ° C (86 ° F to 104 ° F), 0% to 75% | |||||
40 ° C to 55 ° C (104 ° F to 131 ° F), 0% to 40% | |||||
vibration | Random, 2 g, 5-500 Hz, based on MIL - PRF - 28800 - f 2 kind of instruments | ||||
The impact | In accordance with the provisions of IEC 61010-1 version 2, 1 m drop (1 m drop test, six sides, oak floor) | ||||
Electromagnetic compatibility | In a 3 V/M radio frequency magnetic field, precision = specified precision (EN 61326-97) took | ||||
security | Meet the ANSI/ISA 82.02.01 (2004, 61010-1) CAN/CSA - C22.2 NO. 61010-1-04, and IEC/EN 61010-1 version 2, class IV measuring 600 V (IV) | ||||
certification | CSA according to the standard CSA/CAN C22.2 No. 61010.1-04;TUV according to the standard of IEC/EN 61010-1 version 2 | ||||
The battery | 4 AA batteries (NEDA 15 a or IEC LR6) | ||||
Battery life | Insulation testing purposes: | Room temperature, the new alkaline batteries for instrument for at least 1000 times the insulation test.The results of the standard is in 1000 V through 1 M Ω resistance measured, under the condition of the cycle time for 5 seconds, 25 seconds. | |||
Resistance measurement: | Room temperature, the new alkaline batteries for insulation measurement instrument for at least 2500 times earth connection.The results of the standard is in the case of 1 Ω resistance measured, the cycle time for 5 seconds, 25 seconds. | ||||
Size (height x width x length) | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) | ||||
The weight of the | 550 g (1.2 lb) | ||||
IP protection grade | IP40 | ||||
At an altitude of | Work at an altitude of | 2000 m CAT IV 600 V, 3000 m CAT III 600 V | |||
Not operation (deposit) | 12000 m | ||||
Excess capacity | 110% range | ||||
It contains the attachment | TL224 test conductor, TP74 test probes, clip part number is 1958654 (red) and 1958646 (black), holster and remote probe |
Mode雷竞技appl: Fluke 1503 insulation resistance tester
雷竞技appFLUKE - 1503.
Insulation multimeter
Include:
- Remote probe
- The test lead
- The test probe
- Spring clip
- holster