Equipped with 393 FC iFlex probe CAT III 1500 V true RMS clip-on table
The main features
- CAT 1500 V safe level III clip-on table, ensure the security of the measurement
- Fine jaw, can repair the crowded bus cable in the box
- Strong IP54 protection grade, convenient for outdoor use
- With polarity dc power measurement, audio instructions and Visual Continuity for work efficiently
Product description: equipped with 393 FC iFlex probe CAT III 1500 V true RMS clip-on table
Take iFlex雷竞技app Fluke 393 FC CAT III 1500 V true RMS solar clip-on table is a specially designed for the high-voltage direct current environment following work of solar photovoltaic (PV) installation technicians and maintenance professionals design tools: PV arrays, data center, wind energy, electrified railway use UPS uninterruptible power supply.The clip-on table can pass the test wire measure up to 1500 V and 1000 V direct current (DC), AC voltage, and through the jaw measuring up to 999.9 A DC or AC current.The accompanying iFlex flexible current probe alternating current measurement range can be expanded to up to 2500 A.The 393 clip-on table has a fine jaw, enables you to access to the crowded bus cable in the box.In addition, the test conductor is fully considered in the design of your working environment, but also meet the CAT III 1500 V DC safety requirements.
The other main functions:
- IP54 protection grade, especially suitable for outdoor operation of solar arrays and wind power systems
- Dc power measurement, display for the unit with the kVA readings
- Audio instructions the polarity helps to prevent accidental error
- Visual Continuity can provide the bright green light on the LCD screen, very suitable for in the dark and noisy environment, work
- Thr雷竞技appough a Fluke Connect software records and reports the test results
- When measuring ac current, accompanying iFlex flexible current probe allows you to easily in confined Spaces comfortable cable maintenance.IFlex probe can be in tiny space in reverse, and provide accurate current measurement value.
Packing list
- 雷竞技appFluke 393 FC CAT III 1500 V true RMS clip-on table
- Testing wire, the CAT III 1500 V safety level, right Angle plugs, protecting cap
- IFlex 18 inches flexible current probe
- Hang TPAK magnetic tape
- High quality suitcase
- Enjoy 3 years warranty
Product specifications: iFlex probe equipped 393 FC CAT III 1500 V true RMS clip-on table
Specifications: | |||
General information | |||
Any high voltage between terminals and grounding terminals | |||
communication | 1000 V | ||
dc | 1500 V | ||
The battery | 2 AA IEC LR6 alkaline batteries | ||
display | Dual display with backlight | ||
Automatic shutdown | Twenty minutes | ||
electrical | |||
precision | |||
Under the following conditions, valid for one year after the calibration accuracy: working temperature of 18 ° C to 28 ° C, relative humidity 0% to 75%.Precision specifications shown as the following format: + (% of [reading] + [least significant digit value]). | |||
The temperature coefficient of | Temperature is higher than 28 ° C or below 18 ° C, each 1 ° C temperature change, change the specified precision accuracy of 0.1 times | ||
Alternating current: through the jaw | |||
range | 999.9 A | ||
The resolution of the | 0.1 A | ||
precision | 2% + 5 (10 Hz to 100 Hz) | ||
2.5% + 5 (100 Hz - 500 Hz) | |||
Crest factor (50/60 Hz) | 2.5 (600.0 A) | ||
3.0 (500.0 A) | |||
1.42 (999.9 A) | |||
C.F. increase > 2 > 2 | |||
Alternating current: through flexible current probe | |||
range | 999.9 A | ||
2500 A | |||
The resolution of the | 0.1 A (A) 999.9 or less | ||
1 A (2500 A) or less | |||
precision | The 3% reading + 5 (10 Hz to 500 Hz) | ||
Crest factor (50/60 hz) | 2.5 (1400 A) | ||
3.0 (1100 A) | |||
1.42 (2500 A) | |||
C.F. increase > 2 > 2 | |||
Position the sensitivity | |||
The best distance | I2500-10 Flex | I2500-18 Flex | error |
a. | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | Plus or minus 0.5% |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | Plus or minus 1.0% |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | Plus or minus 2.0% |
Measurement uncertainties vacation primary center conductor in the best position, without external electric or magnetic fields and in the operating temperature range. | |||
Dc current | |||
range | 999.9 A | ||
The resolution of the | 0.1 A | ||
precision | The 2% reading + 5[1] | ||
[1]Using ZERO (B) function to compensate the deviation. | |||
Ac voltage | |||
range | 600.0 V | ||
1000 V | |||
The resolution of the | 0.1 V, 600.0 V or less) | ||
1 V, 1000 V or less) | |||
precision | The 1% reading + 5 (20 Hz - 500 Hz) | ||
Dc voltage | |||
range | 600.0 V | ||
1500 V | |||
The resolution of the | 0.1 V, 600.0 V or less) | ||
1 V, 1500 V or less) | |||
precision | The 1% reading + 5 | ||
Dc millivolt | |||
range | 500.0 mV | ||
The resolution of the | 0.1 mV | ||
precision | The 1% reading + 5 | ||
Current frequency: the jaw | |||
range | 5.0 Hz to 500.0 Hz | ||
The resolution of the | 0.1 Hz | ||
precision | The 0.5% reading + 5 | ||
Trigger level | 5 Hz to 10 Hz, 10 or higher A | ||
A 10 Hz to 100 Hz, 5 A or more | |||
100 Hz and 500 Hz, 10 or higher A | |||
Current frequency: by flexible current probe | |||
range | 5.0 Hz to 500.0 Hz | ||
The resolution of the | 0.1 Hz | ||
precision | The 0.5% reading + 5 | ||
Trigger level | 5 Hz and 20 Hz, or 25 A | ||
20 Hz - 100 Hz, or 20 A | |||
100 Hz and 500 Hz, or 25 A | |||
Voltage and frequency | |||
range | 5.0 Hz to 500.0 Hz | ||
The resolution of the | 0.1 Hz | ||
precision | The 0.5% reading + 5 | ||
Trigger level | 5 Hz and 20 Hz, 5 V or higher | ||
20 Hz - 100 Hz, 5 V or higher | |||
100 Hz and 500 Hz, 10 V or higher | |||
Dc power | |||
range | 600.0 kVA (600.0 V dc range) | ||
1500 kVA (1500 V dc range) | |||
The resolution of the | 0.1 kVA | ||
1 kVA | |||
precision | The 2% reading + 2.0 kVA | ||
The 2% reading + 20 kVA | |||
resistance | |||
range | 600.0 Ω | ||
6000 Ω | |||
60.00 k Ω | |||
The resolution of the | 600.0 Ω 0.1 Ω (or less) | ||
6000 Ω 1 Ω (or less) | |||
0.01 k Ω (60.00 k or less Ω) | |||
precision | The 1% reading + 5 | ||
capacitance | |||
range | 100.0 u F | ||
1000 mu F | |||
The resolution of the | 0.1 u F (100.0 u F or less) | ||
1 u F (1000 mu F or less) | |||
precision | The 1% reading + 5 | ||
Surge trigger level | 5 A | ||
Mechanical indicators | |||
Size (length x width x height) | 281 mm x 84 mm x 49 mm | ||
Weight (with battery) | 520 g | ||
Jaw opening | 34 mm | ||
Flexible current probe diameter | The 7.5 mm | ||
Flexible current sensor cable length | |||
(head to electronic connectors) | 1.8 m | ||
Environmental requirements | |||
Working temperature | - 10 ° C to 50 ° C | ||
Storage temperature | To 40 ° to 60 ° C C | ||
Working humidity | No condensation (< 10 ° C) | ||
Relative humidity of 90% or less (10 ° to 30 ° C) C | |||
Relative humidity of 75% or less (30 ° C to 40 ° C) | |||
The relative humidity of 45% or less (40 ° C to 50 ° C) | |||
Work at an altitude of | 2000 m | ||
For altitude | 12000 m | ||
Protection (IP) rating | IEC 60529: IP54, non-working state | ||
Electromagnetic compatibility (EMC) | |||
The international standard | IEC 61326-1: portable electromagnetic environment, IEC 61326-2-2 CISPR 11: group 1, class A | ||
Group 1: equipment to produce and/or the use of conductive coupling radio frequency energy, it is necessary for internal operation with the device itself. | |||
Class A: this equipment is suitable for the family to use and is not directly connected to for residential buildings in any facility in the low voltage power network.Because of the conducted interference and radiated interference, electromagnetic compatibility in other environments may be difficult to guarantee. | |||
Caution: this equipment is used for residential environment, and in such an environment may not provide adequate radio reception. | |||
South Korea's (KCC) | Class A equipment (industrial radio and communication equipment) | ||
Class A: such equipment conforms to the requirement of industrial equipment electromagnetic waves, distributor or user should pay attention to this.This equipment is intended for the business environment, rather than the home environment. | |||
The United States (FCC) | 47 CFR part 15 B child.According to the provisions of article 15.103 of this product is regarded as saving equipment. | ||
security | |||
General information | IEC 61010-1, pollution level 2 | ||
measurement | IEC 61010-2-032:1500 V / 600 V IV CAT CAT III | ||
IEC 61010-2-033:1500 V / 600 V IV CAT CAT III | |||
radio | |||
Radio frequency certification | The FCC ID: T68 - FBLE, IC: 6627 a - FBLE | ||
Radio frequency range | 2400 MHz to 2483.5 MHz | ||
The output power | < 100 mW | ||
Simplified version of the eu compliance declarations | |||
Fluke declare that the product contained in the radio equipment in accordance with directive 2014/53 / EU. | |||
If you need to view the full contents of conformance statement, please visit the following url: | |||
www.雷竞技appfluke.com/en-us/declaration-of-conformity |
Model: equipped with iFlex probe III 1500 V 393 FC CAT true RMS clip-on table
Include:
- Equipped with雷竞技app iFlex probe Fluke 393 FC CAT III 1500 V True - RMS Clamp Meter
- Testing wire, the CAT III 1500 V safety level, right Angle plugs, protecting cap
- IFlex 18 inches flexible current probe
- Hang TPAK magnetic tape
- High quality suitcase
- Enjoy 3 years warranty
Manual + resources: equipped with iFlex probe III 1500 V 393 FC CAT true RMS clip-on table
- The CAT III | application is introduced
- How to safely disconnect in the photovoltaic system no-load opening type isolating switch | application introduction
- As far as possible to improve performance | how to debug a photovoltaic system applications
- Photovoltaic system common fault maintenance | application is introduced