China

雷竞技appFluke 317/319 true RMS ac/dc digital clip-on table/current meter

  • 雷竞技appFluke 317 319
  • 雷竞技appFluke 317 319

The main features

  • Unique 40 A small range, high accuracy of current test - 0.01 A high-resolution, 1.6% high precision measurement
  • Tong head thin, are lightweight, more suitable for use in confined Spaces easily
  • Large backlit display, easy reading in the dark environment
  • Starting current function (319), can be measured, such as motor starting current and lighting equipment
  • Current frequency measurement
  • Digital clip-on table accuracy is higher than 0.01 A and 0.1 V
  • 1000 a ac/dc current measurement (319).
  • 600 v ac/dc voltage measurement
  • 4000 Ω resistance measurements
  • Digital clip-on table sensitive measurement on and off
  • Automatic shutdown function, more to prolong the service life of the battery, so the instrument can work when you want
  • According to retain function, can keep the measured results on the screen
  • One year warranty
The spot
selections1749.00
Tax-inclusive price
Fluke authentic guarantee
With $200 free shipping
Enjoy the return within 7 days

Produc雷竞技appts overview: Fluke 317/319 true RMS ac/dc digital clip-on table/current meter

雷竞技appFluke 317/319 true RMS ac/dc digital clamp type table with ergonomic design, it streamlined appearance more convenient holding in his hand.The two thin, sturdy digital clamp type current meter is more suitable for easy to 1000 (319) and a current measurement used in confined Spaces.317 and 319 have accurate 40 A small range.雷竞技appFLUKE 319 digital clip-on ammeter in addition to have a series of test function, also has the function of starting current and frequency, convenient, the measurement of motor and lighting equipment.


Produc雷竞技appt specifications: Fluke 317/319 true RMS ac/dc digital clip-on table/current meter

Technical specifications
Figures show the frequency
Resolution 6000 words
Battery low battery indicator
Battery low battery indicator
The power supply
Three AAA IEC LR03 batteries
Digital clip-on table jaw opening
1.45 in (37 mm)
Clamp is
1.45 in (37 mm)
Digital clip-on table size (length x width x height)
9.21 in x 2.95 in x 1.37 in
234.0 mm x 75.0 mm x 34.8 mm
Digital clip-on weight table
384 g (including battery)
Automatic range
Ohms
security
CE
EN/IEC 61010-1 and IEC 61010-2-032
Install category III, 600 v work environment

317 technical indicators
Alternating current
range 40.00 A, 600.0 A
The resolution of the 0.01 A, 0.1 A
The accuracy of 1.6% plus or minus 6 word (50 to 60 Hz) 40 {A}
2.5% plus or minus eight word (60-500 Hz) 40 {A}
1.5% + / - 5 word (50 to 60 Hz) {600}
2.5% + / - 5 word (60-500 Hz) {600}
Crest Factor add 2% into the spec for the CF > 2 2.5 Max @ 3.0 Max @ 500 A, 600 A
Ac response Valid values
Dc current
range 40.00 A, 600.0 A
The resolution of the 0.01 A, 0.1 A
The accuracy of 1.6% plus or minus 6 word (40 A)
1.5% + / - 5 words (600 A)
Ac voltage
range 600.0 V
The resolution of the 0.1 V
The accuracy of 1.5% + / - 5 word (20-500 hz)
Ac response Effective straight
Dc voltage
range 600.0 V
The resolution of the 0.1 V
The accuracy of 1% plus or minus 4 words
The resolution of the
range 400.0 Ω, 4000 Ω
The resolution of the 0.1 Ω, 1 Ω
The accuracy of 1% + / - 5 words
Low pass filter parameters Has built-in, 900 hz
On and off measurement
30 or less Ω
Starting current
The response time Do not conform to the
Frequency measurement
range Do not conform to the
The accuracy of Do not conform to the
Trigger level Do not conform to the

319 technical indicators
Alternating current
range 40.00 A, 600.0 A, 1000 A
The resolution of the 0.01 A, 0.1 A, 1 A
The accuracy of 1.6% plus or minus 6 word (50 to 60 Hz) 40 {A}
2.5% plus or minus eight word (60-500 Hz) 40 {A}
1.5% + / - 5 word (50 to 60 Hz) 600/1000 {A}
2.5% + / - 5 digit (60-500 Hz) 600/1000 {A}
Crest Factor and 2% to the specifications for the CF > 2 2.5 Max @ 3.0 Max @ 500 A, 600 A, 1.4 Max @ 1000 A
Ac response Valid values
Dc current
range 40.00 A, 600.0 A, 1000 A
The resolution of the 0.01 A, 0.1 A, 1 A
The accuracy of 1.6% plus or minus 6 word (40 A)
(A) 600/1000 of 1.5% plus or minus five words
Ac voltage
range 600.0 V
The resolution of the 0.1 V
The accuracy of 1.5% + / - 5 word (20-500 hz)
Ac response Effective straight
Dc voltage
range 600.0 V
The resolution of the 0.1 V
The accuracy of 1% plus or minus 4 words
The resolution of the
range 400.0 Ω
4000 Ω
The resolution of the 0.1 Ω
1 Ω
The accuracy of 1% + / - 5 words
Low pass filter parameters Has built-in, 900 hz
On and off measurement
30 or less Ω
Starting current
The response time 100 milliseconds
Frequency measurement
range 5.0 to 500.0 Hz
The accuracy of 0.5% + / - 5 words
Trigger level 10-100 Hz or 5 A, 5-10 Hz, 100-500 Hz or 10 A

All accuracy indexes to 41 ° to 73 ° F + F (23 ° C + / - 5 ° C)

Below 64 ° F and higher than 82 ° F (18 ° C and 28 ° C above)

Environmental parameters:
Digital clip-on table working temperature
14 ° F to 122 ° F (10 ° C to 50 ° C)
Storage temperature
To 40 ° F to 140 ° F (40 ° to 60 ° C - C)
Working humidity
No mist (< 50 ° F) (< 10 ° C)
90% RH (50 ° F to 86 ° F) (10 ° to 30 ° C) C
75% RH (86 ° F to 104 ° F) (30 ° C to 40 ° C)
45% RH (104 ° F to 122 ° F) (40 ° C to 50 ° C)
No mist
Working at high altitude
At an altitude of 2000 meters
Store the altitude
At an altitude of 12000 meters
IP indicators
IP40
Digital clip-on table vibration requirement
The Random MIL - PRF - 28800 - f Class 2, 5-500 Hz, 30 minutes per axis
Drop test requirements
A meter
EMI and RFI, EMC
Not specifically for EMC environment use acuity 0.1 V/m
The temperature coefficient of
Accuracy of 0.1 x (rules) / ° C
(< 64 ° F or > 82 ° F)
18 ° C (< or > 28 ° C)

Mode雷竞技appl: Fluke 317/319 true RMS ac/dc digital clip-on table/current meter

雷竞技appFluke 317/319
雷竞技appFluke 317/319 true RMS ac/dc digital clip-on table/current meter

雷竞技appFluke 319 hs1

Mod雷竞技appel: Fluke 319 hs1 clip-on table

Include:

  • 雷竞技appA Fluke 319 clip-on table
  • TL75 pens and
  • Section 3 AAA batteries
  • IPHS1 crosshead insulation with a screwdriver