雷竞技appThe Fluke 360 leakage current clamp meter | leakage current tester

  • 雷竞技appFluke 360 AC Leakage Current Clamp Meter
  • 雷竞技appFluke 360 AC Leakage Current Clamp Meter
  • 雷竞技appFluke 360 AC Leakage Current Clamp Meter
  • 雷竞技appFluke 360 AC Leakage Current Clamp Meter

The main features

  • The leakage current measuring range for 3 mA, resolution up to 1, including A loss can accurately monitor the insulation material
  • From 1 to 60 mu A A wide measurement range can meet the needs of the various device measuring
  • Advanced shielding technology to ensure that when other wires near the measurements to keep accurate measurements
  • High durability jaw structures can be 50000 times the operation, strengthening the robustness of can prolong the service life of leakage current tester
  • Pocket leakage current tester, easy to carry, the size of the jaw is 40 mm (1.5 in)
  • Convenient "show hold button for the leakage current reading on the inaccessible places
  • With automatic power off function with warning buzzer, can save battery power, extend battery life
  • IEC1010 and EMC standards, it is safe to measurement
  • Meet VDE0404-4 and VDE0702 safety standards of electrical equipment for leakage current and differential current measurements of all applications and performance requirements

Produc雷竞技appts overview: the Fluke 360 leakage current clamp meter | leakage current tester

雷竞技appThe Fluke 360 leakage current tester is durable and high accuracy, is an excellent leakage current measuring instrument.

As a well-designed non雷竞技appinvasive insulation condition detection tools, the Fluke 360 leakage current tester is let you don't need to shut down the system power supply or disconnect device for testing - not only save time, also will have harmful effects on resistance quality or safety.

雷竞技appThe Fluke 360 leakage current tester adopts the unique design of jaw to eliminate the influence of the neighboring current conductor, and reduce the influence of the external magnetic field, even in the environment of the current is very small, also can ensure the accuracy of the test data.In this way, you can in today's complex electrical environment to perform accurate and reliable detection.雷竞技appFluke 360Leakage current tester拥有(坚固的高品质钳口,)高度的稳定性和卓越的耐用性,坚固而优质的夹钳设计保证了高度稳定的长期重复性。

Why to detect leakage current?
Leakage current is an indicator of wires insulation effect.In the use of low insulation resistance or band-pass filter circuit of electronic devices, there may be a high leakage current.Leakage flows lead to equipment and system cannot work normally.Us雷竞技appe the Fluke 360 leakage current tester is performed in the overall measurement of the whole system, can find out the root cause of leakage current.Relative to the insulation test, the main advantage of the leakage current test is you can complete the measurement in the process of normal operation, without turning off the power of the system and equipment.

Produc雷竞技appt specifications: the Fluke 360 leakage current clamp meter | leakage current tester

Regular technical indicators
Detection method
The average
According to
Digital display: 3200 count
Column chart shows: 32, LCD
Measurement cycle
2 times per second (digital display), 12 per second (column chart shows)
Switch range
Automatic adjustment range
The environment temperature and humidity
0 ° C - 50 ° C, 80% RH.Or smaller (condensate)
The temperature coefficient of
0.05% of the range / ° C (0 ° C - 18 ° C and 28 ° C - 50 ° C, measurement range 0 to 50 A)
The influence of external magnetic field
0.0005% of the typical
The influence of the lead position
In the precision range
Circuit voltage
< 300 Vrms
Safety standards
EN 61010-1, EN 61010-2-032300 - V CAT III, 2 levels of pollution protection
Withstand voltage
3.7 kV ac
The battery type
1 x 3 V lithium battery CR2032 (button battery)
Battery life
About 90 hours (continuous use)
Automatically shut down
About ten minutes
To measure the diameter of the conductor
The biggest 40 mm
The weight of the
200 g
size
176 mm x 70 mm x 25 mm
Operating altitude
2000 m
Electrical technical indicators
Standard operating environment
23 + / - 5 DHS C, relative humidity 80% maximum
The accuracy of
Readouts + the value of the least significant bit (%)
3 mA
Resolution:0.001 mA
Accuracy:1% + 5
Maximum allowable current:60 A RMS
30 mA
Resolution:0.01 mA
Accuracy:1% + 5
Maximum allowable current:60 A RMS
30 A
Resolution:0.01 A
Accuracy:1% + 5
Maximum allowable current:60 A RMS
A 60
Resolution:0.1 A
Accuracy:5% + 5
Maximum allowable current:60 A RMS
True RMS average testing and calibration
Precision standard frequency: 50/60 Hz

Mode雷竞技appl: the Fluke 360 leakage current clamp meter | leakage current tester

雷竞技appFluke 360
Leakage current tester
Contains:
  • 雷竞技appFluke 360 AC leakage current tester
  • Soft portable package
  • User manual, including English, French, Spanish, German, Italian, Portuguese, and simplified Chinese version