The main features
- A separable high-pressure clip-on ammeter displays.This product also is a clip-on multimeter use low power 805.15.4 wireless technology, has passed the certification of Chinese radio management committee, not and other wireless products (radios, mobile phones, etc.) interfere with each other
- Removable display can be placed within 10 m away from the table body is convenient, safe place
- IFlex ™ flexible current clamp the extension of the measurement range to 2500 A ac, has higher flexibility, able to measure the irregular size of the conductor
- After the CAT IV 600 V, the CAT III 1000 V safety rating
- Flow measurement technology, can filter out noise, accurately capture the motor starting current
- 雷竞技appFLUKE 381 high-pressure clip-on ammeter has integrated low-pass filter and signal processing function, can be used in the high electrical noise environment, at the same time provide a stable reading
- Human body engineering design, more suitable for one-handed operation
- Easy to read large display screen, automatic range identification
- 雷竞技appFluke 381 clip-on multimeter with true RMS ac voltage and current measurement function, can be precisely measure the nonlinear signal
- The average maximum/minimum/record function can automatically capture all kinds of changes
- Keep reading function, backlight function, more suitable for the occasion of bad light
- Reset function, the screen can be reset, dc measurement
- This product provides the high-quality service support, warranty for 3 years
selections3422.00
Produc雷竞技appt overview: Fluke 381 remote display RMS ac/dc clip-on straight table, using iFlex ™
雷竞技appFluke 381 high-pressure clip-on ammeter is attached to a remote magnetic clamp table display, it has all the features of the universal clip-on ammeter, removable screen make the measurement more convenient and safe;雷竞技appFluke 381也属钳形万用表,其使用方法简便,只要将此钳形万用表夹在导体上,卸下显示屏就可以边操作边读数,原来需要两个人的工作,只需要一个人就可以轻松搞定!新型的IFLEX柔性电流钳(随附),可以将电流量程扩展到2500 A ac,同时使读数更加方便,可以测量尺寸不规则和拥挤的排线。
Meet the following safety standards
IEC/EN 61010-1:01, CAT III 1000 v, 600 v CAT IV
Produc雷竞技appt specifications: Fluke 381 remote display RMS ac/dc clip-on straight table, using iFlex ™
Electrical technical specifications | ||||
Alternating current through the clamp | ||||
range | 999.9 A | |||
The resolution of the | 0.1 A | |||
precision | 2% + / - 5 (10-100 Hz) 5% plus or minus five (100-500 Hz) |
|||
Low pass filter parameters | Has built-in, 800 hz | |||
Crest factor (50/60 Hz) | 3 (500 A) 2.5 (600 A) 1.42 (1000 A) C.F. > 2 increased by 2% |
|||
By flexible current probe of alternating current | ||||
range | 999.9 A / 2500 A (45 Hz - 500 Hz) | |||
The resolution of the | 0.1 A / 1 A | |||
precision | 3% plus or minus five | |||
Crest factor (50/60 Hz) | 3.0 (1100 A) 2.5 (1400 A) 1.42 (2500 A) C.F. > 2 increased by 2% |
|||
Position the sensitivity | ||||
The best distance | ||||
I2500-10 Flex | I2500-18 Flex | error | ||
a. | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | Plus or minus 0.5% | |
B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | Plus or minus 1.0% | |
C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | Plus or minus 2.0% | |
Measurement uncertainties on holiday in the middle of the main lead in the best position, without external electric or magnetic fields and in the operating temperature range. | ||||
Dc current | ||||
range | 999.9 A | |||
The resolution of the | 0.1 A | |||
precision | 2% plus or minus five | |||
Ac voltage | ||||
range | 600 V / 1000 V | |||
The resolution of the | 0.1 V / 1 V | |||
precision | 1.5% plus or minus five (20-500 Hz) | |||
Dc voltage | ||||
range | 600.0 V / 1000 V | |||
The resolution of the | 0.1 V / 1 V | |||
precision | 1% plus or minus five | |||
Starting current | ||||
The response time | 100 ms | |||
Frequency - through the jaw | ||||
range | 5.0 500.0 Hz | |||
The resolution of the | 0.1 Hz | |||
precision | 0.5% plus or minus five | |||
Trigger level | 5-10 Hz, 10 or higher A 10-100 Hz, 5 A or more 100-500 Hz, 10 or higher A |
|||
Through flexible current probe frequency () | ||||
range | 5.0 to 500.0 Hz | |||
The resolution of the | 0.1 Hz | |||
precision | 0.5% plus or minus five | |||
Trigger level | 5 to 20 Hz, or 25 A Between 20 and 100 Hertz, or 20 A 100 to 500 Hz, or 25 A |
|||
resistance | ||||
range | 600 Ω Ω / 60 k / 6 k Ω | |||
The resolution of the | 0.1 Ω Ω / 1/10 Ω | |||
precision | 1% plus or minus five | |||
Mechanical specifications | ||||
Size (length x width x height) | 277 x 88 x 43 mm (remote unit 55 mm) | |||
The weight of the | 350 g | |||
Jaw opening | 34 mm | |||
Flexible current probe diameter | The 7.5 mm | |||
Flexible current sensor cable length (end to wire connection) |
1.8 m | |||
Environmental indicators | ||||
Working temperature | - 10 ° C to + 50 ° C | |||
Storage temperature | To 40 ° C to + 60 ° C | |||
Working humidity | The condensation (< 10 ° C) 90% RH or less (10 ° to 30 ° C) C 75% RH or less (30 ° C to 40 ° C) 45% RH or less (40 ° C to 50 ° C) (condensate) |
|||
Work at an altitude of | 2000 m | |||
For altitude | 12000 meters | |||
EMI and RFI, EMC (EMC) and RF | EN 61326-1:6, EN 61326-2 - "06 ETSI V1.7.1 EN 300, 328:2006 ETSI V1.8.1 EN 300, 489:2008 The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements FCCID: T68 - F381 RSS - 210 IC: 6627 a - F381 |
|||
The temperature coefficient of | More than 28 ° C, below 18 ° C, each with 0.1 x regulation accuracy | |||
Radio frequency | The 2.4 GHz ISM band 10 meters range | |||
Meet safety standards | The ANSI/ISA S82.02.01:2004 CAN/CSA - C22.2 no. 61010-1-4 IEC/EN 61010-1:01 to 1000 v, 600 v CAT CAT III IV. |
|||
Double insulation clearance | In accordance with IEC 61010-2-032 | |||
Double insulation creepage | Conform to the standard IEC 61010-1 | |||
Accredited institution |
Mode雷竞技appl: Fluke 381 remote display RMS ac/dc clip-on table, using iFlex ™
雷竞技appFluke 381
雷竞技appFluke 381 remote display true RMS voltage clip-on ammeter and iFlex
Enclosed is the attachment:
- IFlex flexible current clamp
- Battery operating instruction card
- F38 soft package
- TL175 test pens and
- Section 5 AAA battery (installed)
- AC72 alligator clip (1 black 1 red only)
- Calibration specification statement
- Attached the manual
- Product registration card
Manual + 雷竞技appresource: Fluke 381 remote display RMS ac/dc clip-on table, using iFlex ™
- 雷竞技appFluke 376/381 clamp table introduction (English)
- 雷竞技appFluke 376 and iFlex flexible clamp easy measurement of large current
- 雷竞技appFluke 381 remote display clip-on table allows you to blaugrana
- 雷竞技appFluke 381 l operation demo guide
- 雷竞技appFluke 381 and iFlex flexible current clamp in the narrow space easily complete the measurement
- 雷竞技appFluke 381 iFlex flexible current clamp and high flexibility