雷竞技appFluke FC wireless a3001 current suite

  • 雷竞技appFluke a3001 FC Wireless iFlex ® AC Current Clamp Kit
  • 雷竞技appFluke 3000 FC Industrial System
  • 雷竞技appFluke 805 FC Vibration Meter
  • 雷竞技appFluke 3000 FC Industrial System

The main features

FC wireless a3001 current suite for many common electric parameter measurement

Wit雷竞技apph a Fluke Connect ® application of Fluke 3000 FC series wireless multimeter can satisfy all needs of convenient testing and measuring troubleshooting:

  • Ac and dc voltage measurement, up to 1000 V
  • Ac and dc current is 0.01 mA resolution
  • Connectivity, resistance, diode testing, capacitance and frequency measurement
  • Minimum/maximum record
  • The CAT III 1000 V, the CAT IV 600 V;IP54

Through the wireless iFlex a3001 ™ current module, you can measure size tricky traverse, or into a narrow space and make it easier to wire access:

  • Maximum 2500 A ac measurement
  • It is used as instrument independently or as part of the system
  • For logging, used to record and save as many as 65000 readings
  • Surge function

Produc雷竞技appts overview: Fluke FC wireless a3001 current suite

FC wireless a3001 雷竞技appcurrent suite is a Fluke Connect ® wireless test tools part of the product line

Will a3001 FC current wireless communication module and flexible current probe is connected to your test points, and wireless digital multimeter in 3000 FC on the result of the scope of view as far as 20 meters.

You'll save time, without resistance.the collect multiple measurements.The three-phase system is measur雷竞技apped using multiple modules, can be used as independent measurement tools, or with other Fluke Connect ® frequent testing module combined into a system.

In short, you can even check module reading through closed electrical panel.In addition, no manual record data, because the FC wireless communication module USES current optional PC adapter can capture as many as 65000 groups of min/Max with timestamp/average readings.雷竞技appFluke Connect wireless test tool also by you in the position of the separation of the test point view reading, to improve safety.

Now, you can get in the operation of the reading on the machinery and equipment, only there is a damage risk measurement module

Produc雷竞技appt specifications: Fluke FC wireless a3001 current suite

雷竞技appFluke 3000 FC series wireless multimeter

* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit Numbers]).

Ac voltage
Range creates/resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Precision squared34 45 Hz - 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All ac voltage range has been designated as a range from 1% to 100%.
2. The full scale up to 500 V when the crest factor of 3100 or less linear reduced to 0 V to crest factor < 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading)
4. Do not over 107 V - Hz.
Dc voltage, connectivity, resistance, diode test and capacitance
The mV Range/resolution 600.0 mV / 0.1 mV
precision 0.09% + 2
V Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
precision 0.09% + 2
0.15% + 2
))) Range/resolution Ω Ω / 1, 600
precision < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit.
Ω Range/resolution 600.0 Ω / 0.1 Ω
6.000 k Ω Ω / 0.001 k
60.00 k Ω Ω / 0.01 k
60.00 k Ω Ω / 0.1 k
600.0 k Ω Ω / 0.001 M
Ω 50.00 M / 0.01 M Ω
precision 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range/resolution 2.000 V / 0.001 V
precision 1% + 2
Including F Range/resolution 1000 nF / 1 nF
10.00 u F / 0.01 u F
100.0 u F / 0.1 u F
9999 mu F1 /1 u F
precision 1.2% + 2
10% of the typical
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2.
Ac and dc current
MA AC
(45 Hz to 1 kHz)
Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 1.5% + 3
MA DC squared Range creates/resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 0.5% + 3
1. All alternating current range has been designated as a range from 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.
frequency
Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Precision creates 0.1% + 1
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz.
The input features
Overload protection 1100 Vrms
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
(1 k Ω non-equilibrium)
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Overload protection 1100 Vrms
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
(1 k Ω non-equilibrium)
When the dc to 60 Hz, or more than 60 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Overload protection 1100 Vrms
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
(1 k Ω non-equilibrium)
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Open circuit voltage
Overload protection 1100 Vrms
Input impedance (nominal value) < 2.7 VDC
Full scale voltage to 6 M Ω
Full scale voltage 50 M Ω
< 0.7 VDC
< 0.9 VDC
Typical short-circuit current < 350 mA,
Overload protection 1100 Vrms
Input impedance (nominal value) < 2.7 VDC
Full scale voltage to 6 M Ω
Full scale voltage 50 M Ω
2.000 VDC
Typical short-circuit current < 1.1 mA
MA function
Overload protection 44/100 fuse, A, 1000 V, fuse
overload 600 mA overload for up to 2 minutes, at least 10 minutes to a halt
Minimum/maximum record accuracy
Dc function Duration of > 350 milliseconds to the change of the total + 12 times.
Communication function Duration of > 900 milliseconds changes in total + 40 times.
General technical specifications
The highest voltage between any terminal and earthing 1000 VDC or ac RMS
Ω A input fuse protection 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only
Display (LCD) Update rate 4 / SEC.
The volt, ampere, ohm 6000 times
frequency 10000 times
capacitance 1000 times
The battery type Three AA alkaline batteries, NEDA IEC LR6 15 a
Battery life At least 250 hours
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
The temperature work - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
The temperature coefficient of The set accuracy 0.1 x () / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C)
From 0% to 75% (35 ° C to 40 ° C)
From 0% to 45% (40 ° C to 50 ° C)
At an altitude of work 2000 m
Storage temperature 12000 m
Electromagnetic compatibility
EMI and RFI, EMC (EMC) and RF
EN 61326-1:6, EN 61326-2 - "06
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements
FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE
Meet safety standards The ANSI/ISA 61010-1 / (82.02.01) : the third edition
CAN/CSA C22.2 No. 61010-1-12: the third edition
UL 61010-1: the third edition
IEC/EN61010-1:10
certification CSA, the FCC, CE
Protection (IP) rating IP54
Pollution levels 2
Size (height x width x length) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
The weight of the 340 g (12 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appFluke a3001 FC wireless iFlex ® alternating current module

Technical specifications
range 0.5 A - 2500 - A AC
The resolution of the 0.1 A
precision 3% plus or minus five (5 Hz - 500 Hz)
Crest factor (50 Hz / 60 Hz) 3.0 (1100 A)
2.5 (1400 A)
1.42 (2500 A)
C.F. > 2 increased by 2%
LCD with backlight 3 1/2 level a
Data storage rate/intervals 1 second (minimum)/can be adjusted by PC or the front panel
The battery type 15 A, 2 AA, NEDA IEC LR6
Battery life 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of Increased by 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Working humidity 35 ° C under 90%
40 ° C under 75%
50 ° C under 45%
At an altitude of work 2000 m
Storage temperature 12000 m
Electromagnetic compatibility (EMC) EN 61326-1:6
Meet safety standards IEC 61010-1600 - V class / 1000 V class III, IV third edition
Security level The CAT IV III 1000 V 600 V, the CAT
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP42
Pollution levels 2
Jaw opening 25.4 cm (10) in the coil
Size (high x width x deep) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
The weight of the 0.22 kg (8 oz.)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

Mode雷竞技appl: Fluke FC wireless a3001 current suite

FLK - a3001 FC KIT
雷竞技appFluke FC wireless a3001 current suite
  • 雷竞技appFluke 3000 FC series wireless multimeter
  • 雷竞技appFluke a3001 FC iFlex ac current wireless module
  • TL175 test conductor
  • AC175 alligator clip
  • IFlex i2500-10 flexible current probe

Manual + 雷竞技appresources: Fluke FC wireless a3001 current suite