雷竞技appFluke FC wireless a3001 current suite
The main features
FC wireless a3001 current suite for many common electric parameter measurement
Wit雷竞技apph a Fluke Connect ® application of Fluke 3000 FC series wireless multimeter can satisfy all needs of convenient testing and measuring troubleshooting:
- Ac and dc voltage measurement, up to 1000 V
- Ac and dc current is 0.01 mA resolution
- Connectivity, resistance, diode testing, capacitance and frequency measurement
- Minimum/maximum record
- The CAT III 1000 V, the CAT IV 600 V;IP54
Through the wireless iFlex a3001 ™ current module, you can measure size tricky traverse, or into a narrow space and make it easier to wire access:
- Maximum 2500 A ac measurement
- It is used as instrument independently or as part of the system
- For logging, used to record and save as many as 65000 readings
- Surge function
Produc雷竞技appts overview: Fluke FC wireless a3001 current suite
FC wireless a3001 雷竞技appcurrent suite is a Fluke Connect ® wireless test tools part of the product line
Will a3001 FC current wireless communication module and flexible current probe is connected to your test points, and wireless digital multimeter in 3000 FC on the result of the scope of view as far as 20 meters.
You'll save time, without resistance.the collect multiple measurements.The three-phase system is measur雷竞技apped using multiple modules, can be used as independent measurement tools, or with other Fluke Connect ® frequent testing module combined into a system.
In short, you can even check module reading through closed electrical panel.In addition, no manual record data, because the FC wireless communication module USES current optional PC adapter can capture as many as 65000 groups of min/Max with timestamp/average readings.雷竞技appFluke Connect wireless test tool also by you in the position of the separation of the test point view reading, to improve safety.
Now, you can get in the operation of the reading on the machinery and equipment, only there is a damage risk measurement module
Produc雷竞技appt specifications: Fluke FC wireless a3001 current suite
雷竞技appFluke 3000 FC series wireless multimeter
* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit Numbers]).
Ac voltage | |||
Range creates/resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
||
Precision squared34 | 45 Hz - 500 Hz | 1.0% + 3 | |
500 Hz to 1 kHz | 2.0% + 3 | ||
1. All ac voltage range has been designated as a range from 1% to 100%. 2. The full scale up to 500 V when the crest factor of 3100 or less linear reduced to 0 V to crest factor < 1.5. Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading) 4. Do not over 107 V - Hz. |
|||
Dc voltage, connectivity, resistance, diode test and capacitance | |||
The mV | Range/resolution | 600.0 mV / 0.1 mV | |
precision | 0.09% + 2 | ||
V | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
|
precision | 0.09% + 2 0.15% + 2 |
||
))) | Range/resolution | Ω Ω / 1, 600 | |
precision | < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit. | ||
Ω | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 k Ω Ω / 0.001 k 60.00 k Ω Ω / 0.01 k 60.00 k Ω Ω / 0.1 k 600.0 k Ω Ω / 0.001 M Ω 50.00 M / 0.01 M Ω |
|
precision | 0.5% + 2 0.5% + 1 1.5% + 3 |
||
Diode test | Range/resolution | 2.000 V / 0.001 V | |
precision | 1% + 2 | ||
Including F | Range/resolution | 1000 nF / 1 nF 10.00 u F / 0.01 u F 100.0 u F / 0.1 u F 9999 mu F1 /1 u F |
|
precision | 1.2% + 2 10% of the typical |
||
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2. | |||
Ac and dc current | |||
MA AC (45 Hz to 1 kHz) |
Range creates/ resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|
precision | 1.5% + 3 | ||
MA DC squared | Range creates/resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|
precision | 0.5% + 3 | ||
1. All alternating current range has been designated as a range from 5% to 100%. 2. Enter the load voltage (typical) : 400 mA input 2 mV/mA. 3. According to the 400 mA specified accuracy, overload of 600 mA. |
|||
frequency | |||
Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz |
||
Precision creates | 0.1% + 1 | ||
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz. | |||
The input features | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal value) | > 10 M Ω < 100 pF | ||
Common mode rejection ratio (1 k Ω non-equilibrium) |
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | ||
Norm inhibition | At 50 Hz or 60 Hz greater than 60 dB | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal value) | > 10 M Ω < 100 pF | ||
Common mode rejection ratio (1 k Ω non-equilibrium) |
When the dc to 60 Hz, or more than 60 dB | ||
Norm inhibition | At 50 Hz or 60 Hz greater than 60 dB | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal value) | > 10 M Ω < 100 pF | ||
Common mode rejection ratio (1 k Ω non-equilibrium) |
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | ||
Norm inhibition | At 50 Hz or 60 Hz greater than 60 dB | ||
Open circuit voltage | |||
Overload protection | 1100 Vrms | ||
Input impedance (nominal value) | < 2.7 VDC | ||
Full scale voltage to 6 M Ω Full scale voltage 50 M Ω |
< 0.7 VDC < 0.9 VDC |
||
Typical short-circuit current | < 350 mA, | ||
Overload protection | 1100 Vrms | ||
Input impedance (nominal value) | < 2.7 VDC | ||
Full scale voltage to 6 M Ω Full scale voltage 50 M Ω |
2.000 VDC | ||
Typical short-circuit current | < 1.1 mA | ||
MA function | |||
Overload protection | 44/100 fuse, A, 1000 V, fuse | ||
overload | 600 mA overload for up to 2 minutes, at least 10 minutes to a halt | ||
Minimum/maximum record accuracy | |||
Dc function | Duration of > 350 milliseconds to the change of the total + 12 times. | ||
Communication function | Duration of > 900 milliseconds changes in total + 40 times. | ||
General technical specifications | |||
The highest voltage between any terminal and earthing | 1000 VDC or ac RMS | ||
Ω A input fuse protection | 0.44 A (44/100 A, 440 mA), 1000 V quick fuse, fluke specified components only | ||
Display (LCD) | Update rate | 4 / SEC. | |
The volt, ampere, ohm | 6000 times | ||
frequency | 10000 times | ||
capacitance | 1000 times | ||
The battery type | Three AA alkaline batteries, NEDA IEC LR6 15 a | ||
Battery life | At least 250 hours | ||
Radio frequency communication | The 2.4 GHZ ISM band | ||
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters | |
, gypsum board wall | As far as 6.5 m | ||
Wall, concrete, or steel electric shell | As far as 3.5 m | ||
The temperature | work | - 10 ° C to 50 ° C | |
Storage temperature | To 40 ° to 60 ° C C | ||
The temperature coefficient of | The set accuracy 0.1 x () / ° C (18 ° C or > < 28 ° C) | ||
Relative humidity | From 0% to 90% (0 ° C and 35 ° C) From 0% to 75% (35 ° C to 40 ° C) From 0% to 45% (40 ° C to 50 ° C) |
||
At an altitude of | work | 2000 m | |
Storage temperature | 12000 m | ||
Electromagnetic compatibility EMI and RFI, EMC (EMC) and RF |
EN 61326-1:6, EN 61326-2 - "06 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE |
||
Meet safety standards | The ANSI/ISA 61010-1 / (82.02.01) : the third edition CAN/CSA C22.2 No. 61010-1-12: the third edition UL 61010-1: the third edition IEC/EN61010-1:10 |
||
certification | CSA, the FCC, CE | ||
Protection (IP) rating | IP54 | ||
Pollution levels | 2 | ||
Size (height x width x length) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
The weight of the | 340 g (12 oz) | ||
Warranty period | Three years, | ||
Is雷竞技app not compatible with Fluke CNX testing tools |
雷竞技appFluke a3001 FC wireless iFlex ® alternating current module
Technical specifications | ||
range | 0.5 A - 2500 - A AC | |
The resolution of the | 0.1 A | |
precision | 3% plus or minus five (5 Hz - 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 (1100 A) 2.5 (1400 A) 1.42 (2500 A) C.F. > 2 increased by 2% |
|
LCD with backlight | 3 1/2 level a | |
Data storage rate/intervals | 1 second (minimum)/can be adjusted by PC or the front panel | |
The battery type | 15 A, 2 AA, NEDA IEC LR6 | |
Battery life | 400 hours | |
memory | Can record up to 65000 readings | |
Radio frequency communication | The 2.4 GHZ ISM band | |
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters |
, gypsum board wall | As far as 6.5 m | |
Wall, concrete, or steel electric shell | As far as 3.5 m | |
Working temperature | - 10 ° C to + 50 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
The temperature coefficient of | Increased by 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C) | |
Working humidity | 35 ° C under 90% 40 ° C under 75% 50 ° C under 45% |
|
At an altitude of | work | 2000 m |
Storage temperature | 12000 m | |
Electromagnetic compatibility (EMC) | EN 61326-1:6 | |
Meet safety standards | IEC 61010-1600 - V class / 1000 V class III, IV third edition | |
Security level | The CAT IV III 1000 V 600 V, the CAT | |
certification | CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE | |
Protection (IP) rating | IP42 | |
Pollution levels | 2 | |
Jaw opening | 25.4 cm (10) in the coil | |
Size (high x width x deep) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
The weight of the | 0.22 kg (8 oz.) | |
Warranty period | Three years, | |
Is雷竞技app not compatible with Fluke CNX testing tools |
Mode雷竞技appl: Fluke FC wireless a3001 current suite
- 雷竞技appFluke 3000 FC series wireless multimeter
- 雷竞技appFluke a3001 FC iFlex ac current wireless module
- TL175 test conductor
- AC175 alligator clip
- IFlex i2500-10 flexible current probe
Manual + 雷竞技appresources: Fluke FC wireless a3001 current suite
- 3000 FC | user manual
- 3000 FC | quick reference guide
- 3000 FC | calibration manual
- 3000 FC | calibration manual addendum
- The a3000 FC | calibration manual
- The a3000 FC | quick reference guide
- A3001 FC | calibration manual
- A3001 FC | quick reference guide
- A3002 FC | calibration manual
- A3002 FC | quick reference guide
- 雷竞技appFluke Connect | quick reference guide
- 雷竞技appFluke Connect wi-fi to Thermal Imager | quick reference guide
- Ir3000 FC | quick reference guide
- PC 3000 FC | instructions page
- T3000 FC | quick reference guide
- T3000 FC | calibration manual
- V3000 FC | calibration manual
- V3000 FC v3001 FC | quick reference guide
- V3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC statement | non-volatile memory
- 雷竞技appFluke Connect video is introduced: using TrendIt chart function identification of intermittent fault
- 雷竞技appFluke Connect video introduction: how to save measurements to EquipmentLog history
- 雷竞技appFluke Connect video introduction: how to create equipment through EquipmentLog history function benchmark
- 雷竞技appFluke Connect to perform predictive maintenance
- Us雷竞技appe Fluke Connect the application from a safe distance measurement
- Using ShareLive video sharing real-time measurements and video call function
- How 雷竞技appto use the Fluke Connect application sharing equipment measurements
- How to record the measured value and draw diagrams
- Records automatically by the AutoRecord measurement function measurements
- Th雷竞技apprough the Fluke Connect Connect multiple tools at the same time