雷竞技appFluke 1551 a "good" a thermometer and temperature calibrator
The main features
- Intrinsically safe, battery power, portable reference thermometer
- Full range accuracy is + / - 0.05 ° C (+ / - 0.09 ° F)
- Intrinsically safe job characteristics (ATEX and IECEx standard)
- Measuring temperature: - 50 ° C to 160 ° C (58 ° F to 320 ° F) -
- Use trend/stability indicating available, users can configure the temperature
- According to temperature unit ° C or ° F
- May choose to record data to the internal storage
Produc雷竞技appts overview: Fluke 1551 a "good" a thermometer and temperature calibrator
雷竞技appFluke 1551 a "great" thermometer has all the features of the 1552 a, but the temperature range is relatively narrow: to 50 ° C to 160 ° C (- 58 ° F to 320 ° F).雷竞技appFluke 1552 a provides a repeatable temperature measurement, the full range of accuracy of + / - 0.05 ° C.Have essential safety degree, is suitable for the existence of explosive gas indoor or outdoor environment.For a potentially explosive environment, such as processing factory workshop, the thermometer is very good choice.The battery power, portable reference thermometer is daily check the thermometer, regulatory transfer temperature calibration measurement, PET, LIG calibration and temperature transmitter calibration and verification.
Stainless steel probe and digital readout device fixed together, and as a calibration system.Wide backlit LCD display can be rotated 90 °, from any Angle can be easy reading.And user configurable stability/trend indicator, make technical personnel know when the temperature is stable enough, accurate measurement and record the value.User can set up automatic shutdown function, the typical battery life extended to 300 hours.Low battery indication and stop function can prevent the measurement error due to insufficient battery life.In addition, the use of three-point calibration function, easy and accurate calibration 15512 a.
Other useful features:
Stainless steel probe and digital readout device fixed together, and as a calibration system.Wide backlit LCD display can be rotated 90 °, from any Angle can be easy reading.And user configurable stability/trend indicator, make technical personnel know when the temperature is stable enough, accurate measurement and record the value.User can set up automatic shutdown function, the typical battery life extended to 300 hours.Low battery indication and stop function can prevent the measurement error due to insufficient battery life.In addition, the use of three-point calibration function, easy and accurate calibration 15512 a.
Other useful features:
- With 300 hours of battery life
- Battery life percentage display as well as the low battery indicator
- Including NVLAP certification and NIST traceable calibration
Produc雷竞技appt specifications: Fluke 1551 a "good" a thermometer and temperature calibrator
Technical indicators | |
Temperature range: | - 50 ° C to 160 ° C 58 ° F to 320 ° F (-) |
Accuracy (1 year) | + / - 0.05 ° C (+ / - 0.09 ° F) |
According to the unit | ° C, ° F |
The sensor type | 100 Ω thin-film RTD |
The probe temperature coefficient | Ω Ω / 0.00385 ° C, the nominal value |
The length of the sensor | 10 mm or less |
Sensor position sheath cutting-edge (distance) | 3 mm (0.1 in) |
Minimum submergence depth | 7 cm (2.8 in) |
The probe sheath material | Stainless steel |
The response time | 4.8 mm diameter probe (3/16 in) : 14 seconds 6.35 mm diameter probe (1/4) in 21 seconds |
The probe delay | + / - 0.01 ° C |
The temperature resolution | Optional: 0.1, 0.01, 0.001 (0.01 by default) |
Sampling rate | Optional: 0.5 seconds, one second, 2 seconds (default 1 second) |
Working temperature range readings | - 10 ° C to 50 ° C (14 ° F to 122 ° F) |
The temperature resolution | Optional: 0.1, 0.01, 0.001 (0.01 by default) |
Sampling rate | Optional: 0.5 seconds, one second, 2 seconds (default 1 second) |
Working temperature range readings | - 10 ° C to 50 ° C (14 ° F to 122 ° F) |
Storage temperature | - 20 ° to 60 ° C - C (4 ° F to 140 ° F) 0% to 95% RH, no condensation |
Optional data logging1 | Internal memory can store up to 10000 time-stamped readings |
Record interval1 | 2 seconds, 5 seconds, 10 seconds, 30 seconds or 60 seconds. 2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes |
damping | Moving average 2 to 10 reading recently (on/off, 2, 5, 10) |
communication | Rs - 232 stereo jacks (only access to the calibration parameters) |
The ac power | There is no |
Dc power supply | Section 3 AAA batteries, typical battery life of 300 hours, LCD backlight off |
EMC compliance: | EN61326:2006 Annex C;CISPR II Edition 5.0-2009;Class B |
Protection level | IP50 |
Electronic equipment size (length x width x height) | 57 x 114 x 25 mm (4.5 x 2.25 x 1.0 in) |
The weight of the | 196 g (6.9 oz) |
Calibration (including) | NVLAP certification, NIST traceable |
characteristic | CVD |
1. The optional configuration data record, please see the order information |
Mode雷竞技appl: Fluke 1551 a "good" a thermometer and temperature calibrator
雷竞技appFluke 1551-12 a
1551 a Ex thermometer, fixed RTD,
- 50 ° C to 160 ° C,
6.35 mm x 305 mm (1/4 in x 12) in
Contains NVLAP certification of calibration report, user manual CD type, section 3 AAA batteries
- 50 ° C to 160 ° C,
6.35 mm x 305 mm (1/4 in x 12) in
Contains NVLAP certification of calibration report, user manual CD type, section 3 AAA batteries
The attachment
- NVLAP certification of calibration report
- User manual CD
- Section 3 AAA batteries
雷竞技appFluke 1551-9
1551 a Ex thermometer, fixed RTD,
- 50 ° C to 160 ° C,
4.8 mm x 229 mm (3/16 in x 9 in)
Contains NVLAP certification of calibration report, user manual CD type, section 3 AAA batteries
4.8 mm x 229 mm (3/16 in x 9 in)
- 50 ° C to 160 ° C,
4.8 mm x 229 mm (3/16 in x 9 in)
Contains NVLAP certification of calibration report, user manual CD type, section 3 AAA batteries
4.8 mm x 229 mm (3/16 in x 9 in)
- NVLAP certification of calibration report
- User manual CD
- Section 3 AAA batteries
雷竞技appFluke 1551 - a - 9 - DL
1551 a Ex data recording option
The thermometer, fixed RTD,
- 50 ° C to 160 ° C,
4.8 mm x 229 mm (3/16 in x 9 in), data recording option
Contains NVLA
4.8 mm x 229 mm (3/16 in x 9 in), data recording option
The thermometer, fixed RTD,
- 50 ° C to 160 ° C,
4.8 mm x 229 mm (3/16 in x 9 in), data recording option
Contains NVLA
4.8 mm x 229 mm (3/16 in x 9 in), data recording option
- NVLAP certification of calibration report
- User manual CD
- Section 3 AAA batteries
雷竞技appFluke a - 12-1551 DL
1551 a Ex data recording option
The thermometer, fixed RTD,
- 50 ° C to 160 ° C,
6.35 mm x 305 mm (1/4 in x 12 in), data recording option
Contains NVLAP certification of calibration report, user manual CD type, section 3 AAA batteries
The thermometer, fixed RTD,
- 50 ° C to 160 ° C,
6.35 mm x 305 mm (1/4 in x 12 in), data recording option
Contains NVLAP certification of calibration report, user manual CD type, section 3 AAA batteries
The attachment
- NVLAP certification of calibration report
- User manual CD
- Section 3 AAA batteries
雷竞技appFluke 1551 a - 20
1551 a Ex thermometer, fixed RTD,
- 50 ° C to 160 ° C,
6.35 mm x 508 mm (1/4 in x 20) in
Contains NVLAP certification of calibration report, user manual CD, section 3 AAA batteries
- 50 ° C to 160 ° C,
6.35 mm x 508 mm (1/4 in x 20) in
Contains NVLAP certification of calibration report, user manual CD, section 3 AAA batteries
The attachment
- NVLAP certification of calibration report
- User manual CD
- Section 3 AAA batteries
雷竞技appFluke 1551 - a - 20 - DL
1551 a Ex data recording option
The thermometer, fixed RTD,
- 50 ° C to 160 ° C,
6.35 mm x 508 mm (1/4 in x 20 in), data recording option
The thermometer, fixed RTD,
- 50 ° C to 160 ° C,
6.35 mm x 508 mm (1/4 in x 20 in), data recording option
The attachment
- NVLAP certification of calibration report
- User manual CD
- Section 3 AAA batteries