I30 AC/DC current clamp table
The main features
- Current clamp using hall effect technology, can measure the dc and ac current
- Contains the banana plugs, compatible with multimeter
- Current range: 30 mA - 30 A dc, 30 mA - 20 A ac RMS
- Frequency range: dc to 20 kHz (0.5 dB)
- The CAT III 300 V safety rating
Products overview: i30 AC/DC current clamp table
I30 current clamp table based on the working principle of hall effect technology, suitable for measuring the dc and ac current.I30 can with multimeter, recorder, and other appropriate recording instrument, and thus for the accurate noninvasive current measurements.
Product specifications: i30 AC/DC current clamp table
Electrical technical indicators | |
Specify the current range | 30 mA - 30 A dc, 30 mA - 20 A ac RMS |
Current range available | 5 30 mA mA - 30 A dc, ac RMS - 20 A |
Crest factor | 1.4 in |
The output sensitivity | 100 mV/A |
Precision (+ 25 ° C) | Dc, reading plus or minus 1%, plus or minus 2 mA Communication, reading plus or minus 0.5 dB, plus or minus 2 mA |
The resolution of the | Plus or minus 1 mA |
The load impedance | > 10 k Ohm and pf 100 or less |
Wire position sensitivity | Centered relative reading plus or minus 1% |
Frequency range | Dc to 20 kHz (0.5 dB) |
The temperature coefficient of | Readings of plus or minus 0.01% / ° C |
The power supply | 9 V alkaline battery, MN1604 / PP3, 30 hours, low battery indicator |
Working voltage college (see section "safety standard") | 300 V ac RMS or dc |
General technical indicators | |
The largest wire size can be obtained | 19 mm diameter |
Output connection | 4 mm secure connector |
Output zero | Obtained by manual regulation refers to the wheel |
The length of the cable | 1.5 m |
Working temperature range | 0 ° C to + 50 ° C |
Storage temperature range (battery out) | - 20 ° C to + 85 ° C |
Working humidity | From 15% to 85% (without condensate) |
The weight of the | 250 g |
security | IEC 61010-1, pollution level 2 |
IEC 61010-2-032: the CAT III 300 v | |
In the absence of insulated conductor is to use the probe shall not exceed 300 V dc, ac RMS or below 1 kHz and frequency. | |
EMC compatibility | IEC 61326-1: portable device of electromagnetic environment |
Model: i30 AC/DC current clamp table
雷竞技appFluke i30
I30 AC/DC current clamp table