Products overview: MBX clamp table 5 A / 50 A current clamp table
Using double range 5雷竞技app a / 50 a current clamp table expansion of 1735 and the Fluke Fluke 1740 series recorder function.Accessories include four high precision clamp table.After connection, recorder can automatic detection and analysis them.
Product specifications: MBX clamp table 5 A / 50 A current clamp table
Technical specifications | ||
Electrical characteristics | Rated current | 50 A ac RMS |
overload | The biggest 100 A RMS | |
Wire position influence | Less than 0.5% of range (50/60 Hz) | |
Error due to adjacent wires: | 15 or less mA/A (50 Hz) | |
200 A, the phase shift when 2 kHz | < + 1 ° | |
Frequency range | 40 Hz to 10 kHz (3 dB) | |
The temperature coefficient of | 0.015% of the range / ° C | |
Working voltage (see section "safety standard") | 600 V AC RMS or DC | |
To place an order for reference | A phase: EP0442A | |
Three phase: EP0452A | ||
Three-phase + N: EP0453A | ||
precision | The primary current 0.125 A and 2.5 A | Work error (expressed as a % of readings) : 2.5% |
Phase shift: not specified | ||
The primary current: 2.5 A and 12.5 A | Work error (expressed as a % of readings) : 1.5% | |
Phase shift: < 2 ° | ||
The primary current: 12.5 A to 25 A | Work error (expressed as a % of readings) : 0.5% | |
Phase shift: < 0.5 ° | ||
The primary current: A 25 to 50 A | Work error (expressed as a % of readings) : 0.5% | |
Phase shift: < 1 ° | ||
Regular feature | The largest wire size can be obtained | 15 x 15 mm in diameter, bus 17 mm |
The length of the cable | 2 m. | |
Working temperature range | - 10 ° C to + 55 ° C | |
Storage temperature range | - 20 ° C to + 70 ° C | |
Working humidity | Relative humidity of 15% to 85% (condensate) | |
Weight (each clamp) | 175 g | |
Reference conditions | Ambient temperature range | + 18 ° C to + 26 ° C |
humidity | Between 20% and 75% relative humidity | |
current | Sine wave, 48 to 65 Hz, distortion factor: < 1%, no dc component | |
The output voltage of load impedance | 1 M or more Ω, < 100 pF | |
Safety standards | IEC/EN61010-1:2001 | |
IEC/EN61010-2-032 | ||
IEC/EN61010-2-031 | ||
Security level | 600 V CAT III (third class), pollution level 2 | |
When used on not insulated wire clamp, shall not exceed 600 V ac RMS of voltage or dc, and the frequency is lower than 1 kHz. | ||
EMC standard | EN61326-1:1997 / A1:1998 | |
size | 102 x 42.5 x 23.5 mm |
Model: MBX clamp table 5 A / 50 A current clamp table
雷竞技appFluke MBX Clamp 5 a / 50 a
MBX clamp table 5 A / 50 A current clamp table