China

雷竞技appFluke 28 Ex ii this type Ann true RMS digital multimeter

  • 雷竞技appFluke 28 Ex ii this type Ann true RMS digital multimeter
  • 雷竞技appFluke 28 Ex ii this type Ann true RMS digital multimeter
  • 雷竞技appFluke 28 Ex ii this type Ann true RMS digital multimeter

The main features

Safety and compliance certification

The 28 Ex ii/CN explosion-proof authentication was obtained from the world's authoritative certification body.

28 the Ex II/CN I.S. certification

  • IECEx Ex ia IIC T4 Gb, I M1 Ex ia Ma I

28 the Ex II/CN security and compliance

  • ISA - 82.02.01
  • CAN/CSA - C22.2 no. 61010-1-04 / UL61010-1:20 04, and TUV 61010-1:01
  • CE
雷竞技appFluke 28 Ex ii/CN is durable the Ann type digital multimeter.
  • Completely sealed, IP67 degree of protection
  • Can withstand ten feet or 3 m height of drop
  • Dust, in line with the IEC60529 IP6x
  • Waterproof, accord with IEC60529 IP6x IEC overvoltage electrical safety standards no. 61010-1:01
    • 1000 V (V) (III) the third type of measurement standards, the pollution level 2
    • 600 V (V) the fourth class measure (CAT) IV, pollution level 2
  • When not in use, reversible jacket can strengthen the protection of the display

Produc雷竞技appts overview: Fluke 28 Ex ii this type Ann true RMS digital multimeter

Fluke 28 Ex II industrial safety type digital multimeter with all measurement function.

Whether you're in ATEX zone 1, 2, 21 or 22 of internal or external, the tool will provide you with all the required testing and troubleshooting functions.Need for different area with different instrument, also need not worry about carrying the explosion protection level tools through the area.

  • 4-1/2 digital model to realize accurate measurement (20000 words)
  • True RMS ac voltage and current can be accurately measured nonlinear signal
  • Can measure up to 1000 v and 10 a ac and dc voltage and current (note the Ex area to reduce measurement)
  • Low-pass filter to ensure that the variable speed drive (VSD) accurately measure the voltage and frequency
  • Up to 200 kHz frequency and duty ratio can help you diagnose the VSD and switch power supply
  • Resistance, connectivity and diode testing
  • Motor startup or capacitance range of components for the 10000 u F
  • High resistance or leakage test conductivity measurement
  • Capture the minimum/maximum average and peak to record the change of the transient and automatically
  • Rule out relative resistance measurement test wire interference pattern
  • Can be manually and automatically select range and strong flexibility
  • When the wires into the wrong input jacks, input the alert will be issued songs and twinkle "Lead", to protect your security

Easy to use

Important additional functions ensures that you are in poor condition of the location of the all day to maintain a high work efficiency.

  • Even if you wear full set of PPE, backlit keyboard button can also be used in lighting of poor areas to provide you with good visibility
  • Large digital display and level 2 bright white backlight also increased visibility
  • Long battery life - no backlighting usually for 400 hours (alkaline batteries)
  • Optional magnetic hook, easy to set up and easy reading, let you free hands to do other work

The convenient maintenance

Split type battery pack make replacement battery or the fuse is simple, and will not damage the accuracy of the instrument.

Now there's a can be used in the IIC (gas) 1 zone and 2 zone and IIIC (dust) zone 21 and 22 OuDeBen Ann multimeter (DMM).Whether you are in the oil industry, chemical industry environment or pharmaceutical work environment, you can through the fluke manufacturing the durability of the Ann model (IS) multimeter (DMM) to obtain all the necessary testing and troubleshooting functions.At the same time, fluke 28 Ex ii/CN waterproof, dustproof, resistance to fall off.Use the fluke 28 Ex ii/CN, you can deal with all the situation, whether it is in the danger zone or dangerous zone, and not goes against regulations or sacrifice performance measurement.

Produc雷竞技appt specifications: Fluke 28 Ex ii this type Ann true RMS digital multimeter

Precision specifications
Precision specifications displayed as plus or minus (reading % + effective digits)
Dc voltage range 0.1 mV to 1000 V
precision Plus or minus 0.05% + 1
Ac voltage range 0.1 mV to 1000 V
precision Plus or minus 0.7% + 4
Dc current range 0.1 mu A to 10 A
precision Plus or minus 0.2% + 4
Alternating current range 0.1 mu A to 10 A
precision Plus or minus 1.0% + 2
resistance range 0.1 Ω Ω to 50 M
precision Plus or minus 0.2% (+ 1)
conductance range 60.00 nS
precision Plus or minus 1.0% (+ 10)
Diode test range 2.0 V
precision Plus or minus 2.0% (+ 1)
Duty ratio range Between 0.0% and 99.9%
precision Rise time < 1 (including s, or minus (+ 0.1% / 0.2% kHz) range
capacitance range 10 the nF - 9999 mu F
precision Plus or minus 1.0% (+ 2)
frequency range 0.5 Hz to 199.99 kHz
precision Plus or minus 0.005% (+ 1)
The temperature range - 200 ° C to + 1090 ° C (328 ° F to 1994 ° F) +
precision Plus or minus 1.0% (+ 10) ° C [+ / - 1.0% (+ 10) ° F]
Display the count High resolution mode for counting for 6000/19999
Peak capture Record the transient is as high as 250 us
The minimum/maximum average/record Signal rate is as high as about 100 ms
Precision specifications displayed as plus or minus (reading % + effective digits)
Safety certification
ATEX II 2 G Ex ia IIC T4 Gb
II 2 D Ex ia IIIC T130 ° C Db
I M1 Ex ia Ma I
NEC - 500. Class I, Div 1, A - D group, 130 ° C
IEXEx The Ex ia IIC T4 Gb
The Ex ia IIIC T130 ° C Db
The Ex ia Ma I
GOST R Ex Over voltage protection: 1000 V (V) three kinds of measurement standards (CAT III), pollution level 2
600 V (V) the fourth class measure (CAT) IV, pollution level 2
Protection grade IP67
General technical indicators
power
Three AAA batteries
Battery life: 400 hours
display LCD with backlight
External protection Rubber sheath
Warranty period Three years,
Size (height x width x length) (with holster) 6.35 x 10.0 x 19.81 cm (2.5 x 3.93 x 7.8 in)
Weight (with holster) 698.5 g (1.54 lb)

Mode雷竞技appls: Fluke 28 Ex ii this type Ann true RMS digital multimeter

雷竞技appFluke 28 Ex II/CN
Fluke 28 type ii Ex/CN this Ann true RMS digital multimeter
  • Including: the sheath
  • Alligator clip
  • The test line
  • The battery
  • The user manual
  • Cd-rom disks