雷竞技appFluke 718 ex this type pressure calibrator
The main features
雷竞技appFluke 718 ex:
- ATEX EEx ia II 1 g IIC T4 Compliant
- The built-in pressure/vacuum hand pump, with fine tuning knob and discharge valve
- Can now provide 200 kpa, 700 kpa and 2100 kpa module built-in pressure range
- Using internal pressure sensors, pressure measurement accuracy of 0.05% of full scale
- Us雷竞技appe Fluke 700 pex pressure module, pressure measurement to 200 bar
- A variety of optional pressure units
- Flow measurement accuracy was 0.02%, and the resolution of 0.001 mA
- Pressure switch testing capabilities
- The minimum - maximum holding function
- Compact fuselage
- Simple, button type user interface
- Solid, reliable and suitable for field application
Produc雷竞技appts overview: Fluke 718 ex this type pressure calibrator
雷竞技appFluke 718 ex is a new type of the Ann model pressure calibrator, can be used for the explosion danger area.
View: total pressure calibration solution, all the problem solved
Produc雷竞技appt specifications: Fluke 718 ex Ann type pressure calibrator
Pressure measurement accuracy | ||
雷竞技appFluke 718 ex 30 g | range | - 830 mbar to 2 bar (internal sensor) The overpressure: 3 x the FS |
The resolution of the | 0.0001 bar | |
precision | 0.05% FS | |
function | Zero, minimum, maximum, maintain, and attenuation | |
雷竞技appFluke 718 ex 100 g | range | - 830 mbar to 6.9 bar (internal sensor) The overpressure: 2 x the FS |
The resolution of the | 0.001 bar | |
precision | 0.05% FS | |
function | Zero, minimum, maximum, maintain, and attenuation | |
雷竞技appFluke 718 ex 300 g | range | - 830 mbar to 20 bar (internal sensor) The overpressure: 375 psi (25 bar) |
The resolution of the | 0.0001 bar | |
precision | 0.05% FS | |
function | Zero, minimum, maximum, maintain, and attenuation | |
雷竞技appFluke 718 ex series | range | Through the pressure module connector 29 pressure module, 2.5 mbar to 700 bar The overpressure, according to the pressure module specification |
The resolution of the | According to the pressure module specification | |
precision | According to the pressure module specifications, to 0.025% of full scale | |
function | Zero, minimum, maximum, maintain, and attenuation | |
The source pressure, built-in pump range | - 820 mbar to full scale | |
Suitable for the corrosive gas. Support pressure units including psi, inH2The O (4 ° C), inH2O (20 ° C), kPa, cmH2The O (4 ° C), cmH2O (20 ° C), bar, mbar, kg/cm squared, mmHg, inHg Medium compatibility, pressure module according to specifications |
||
Technical parameters | ||
Accuracy of measurement | range | 0 to 24 mA |
The resolution of the | 0.001 mA | |
precision | Reading of 0.02% plus or minus 2 words | |
display | LCD display 5 digit pressure and current value at the same time | |
Environmental indicators | ||
Working temperature | - 10 ° C to 55 ° C | |
Storage temperature | To 40 ° to 60 ° C C | |
Humidity (no condensation) | 95% (10 ° to 30 ° C) C | |
75% (30 ° C to 40 ° C) | ||
45% (40 ° C to 50 ° C) | ||
35% (50 ° C to 55 ° C) | ||
Work at an altitude of | Up to 3000 m | |
Safety specifications | ||
security | Comply with ATEX II Ex 1 gIa IIC T4 | |
CSA certification I.S. grade I | ||
Class 1 A - D group, T4 | ||
The mechanical and general specifications | ||
Size (length x width x height) | 216 x 94 x 66 mm (with holster) | |
The weight of the | About 992 g (with holster) | |
Warranty period | Three years, the pump is one year | |
The impact | 1 m drop test | |
vibration | Randomness, 2 G, 5-500 Hz | |
The battery type | Section 9 V alkaline battery ANSI/NEDA 1604 a or IEC 6 lr619v | |
Battery life | 4 to 20 hours, depending on the function |
Mode雷竞技appl: Fluke 718 ex this type pressure calibrator
雷竞技appFluke 718 ex 30 g
Pressure calibrator
Each of the calibrator are including:
- The red cover
- TL75 test line
- AC72 test clip
- Medium filter
- CD version of the user manual (in English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, swe, Finland, Finnish, Portuguese, Korean, Chinese, Japanese)
雷竞技appFluke 718 ex 100 g
Pressure calibrator
Each of the calibrator are including:
- The red cover
- TL75 test line
- AC72 test clip
- Medium filter
- CD version of the user manual (in English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, swe, Finland, Finnish, Portuguese, Korean, Chinese, Japanese)
- Fluke 718 ex CCD content control chart
- NIST traceable calibration reports and data
雷竞技appFluke 718 ex 300 g
Pressure calibrator
Each of the calibrator are including:
- The red cover
- TL75 test line
- AC72 test clip
- CD version of the user manual (in English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, swe, Finland, Finnish, Portuguese, Korean, Chinese, Japanese)
- 雷竞技appFluke 718 ex CCD control chart
- NIST traceable calibration reports and data