雷竞技appFluke 810 vibration
The main features
- Of common mechanical failure (bearing, loss, unbalanced, loosen) implementation onboard identification and localization, make the maintenance work focused on the fault source, reduce unplanned downtime
- Through the overall vibration level, you can directly from the diagnosis of rapid assessment screen machine running status as a whole
- Severity has four severity rating scale, to help you determine the priority of the maintenance work
- For the technical personnel to provide the correct maintenance measures
- A detailed diagnostic report and the spectrum diagram, help identify the data quality, and narrow the scope of the failure root cause
- Onboard associated sensitivity, helps to provide real-time tips and guidance for new users
- Machine speed flexible configuration, to test a wide range of assets, including the belt drive, gear box and bevel gear
- 2 GB extensible on-board memory provides enough space to store the machine data
- Self-checking function to ensure good performance and work longer hours
- Laser tachometer can accurately measuring machine running speed, so as to improve the accuracy of the diagnosis
- Three-axis accelerometer measurement time than uniaxial accelerometer by two-thirds
- Viewer PC software expands the data storage and tracking capacity
Use雷竞技app Fluke 810 vibration can:
- Diagnosis of fault equipment and understand the root cause
- In the planned maintenance before and after inspection equipment, and confirm the maintenance effect
- Commissioning new equipment and ensure correct installation
- Provide quantifiable equipment status, and push for repair or replacement
- Set priorities and schedule maintenance activities, work more efficiently
- Before the equipment failure prediction before failure, and control spare parts inventory
- Training for new or inexperienced technicians and build trust and to develop skills in the team
Produc雷竞技appts overview: Fluke 810 vibration
雷竞技appFluke 810 vibration: meet your urgent demand...
Through vibration test method, the control of unplanned downtime, prevent repetitive problems, set priorities and manage your resources of maintenance.
雷竞技appFluke 810 vibration tester is advanced troubleshooting tools, can meet the requirements of mechanical maintenance personnel is imminent.Good diagnostic techniques that can help you quickly identify mechanical problems and determine priorities, make you master vibration analyst expertise.
Your factory, team work and make you proud.Your technology to make the normal operation, but sometimes I do not have enough time or resources to catch up with the work progress, not to mention the initiative for mechanical maintenance.雷竞技appFluke 810 vibration将功能强大的诊断引擎与简单的分步流程结合在一起,无需参考测量历史记录,在第一次测量时即可针对特定的机器故障及其严重程度进行报告,从而让您更快一步。总体振动测量和频谱图让技术人员能够迅速评估机器总体运行状况,而增强的报告和切实可行的建议给予您解决关键问题首先需要的信心。
View: how to use the fluke vibration diagnostic tool, easy maintenance all rotating equipment
Produc雷竞技appt specifications: Fluke 810 vibration
Diagnosis of technical indicators | ||
Standard fault | Imbalance, and loose and bearing failure | |
Analysis of the | Motor, fan, blower, belt and chain drives, gearbox, coupling, centrifugal pumps, piston pump, vane pump, screw pump, screw pump, rotary screw / / CAM gear pumps, piston compressor, centrifugal compressor, screw compressor, closely connected machines, spindle | |
Machine speed range | 200 RPM to 12000 RPM | |
Diagnosis of details | Plain text diagnosis, failure severity level (mild, moderate, severe and very severe), details of maintenance, reference peak, frequency spectrum | |
Electrical technical indicators | ||
Range transform | automatic | |
A/D converter | 4 channel, 24 | |
The available bandwidth | 2 Hz and 20 kHz | |
The sampling | 51.2 Hz | |
Digital signal processing function | Automatic configuration of distortion filter and high-pass filter, sampling, overlapping, add window, FFT and average | |
Sampling rate | 2.5 kHz and 50 kHz | |
Dynamic range | 128 dB | |
Signal to noise ratio | 100 dB | |
FFT resolution | 800 line | |
Spectrum window | Hanning window (Hanning) | |
Frequency unit | Hz, the orders, CPM | |
Amplitude of the unit | In/SEC, mm/SEC, VdB (USA), the VdB * (Europe) | |
Nonvolatile memory | SD micro memory card + user extensions, 2 GB memory storage tank (additional storage space) | |
General technical indicators | ||
Size (high x width x) | 18.56 x 7.00 x 26.72 cm (7.30 x 2.76 x 10.52 in) | |
Weight (including battery) | 1.9 kg (4.2 lb) | |
display | Quarter of VGA, 320 x 240 color (5.7 inches) diagonal LED backlight TFT LCD | |
Input/output connections | Three axis sensor connection | 4 needle M12 connector |
Single shaft sensor connection | BNC connector | |
Tachometer connection | The Mini DIN 6 pin connector | |
PC connection | The Mini 'B' USB connector (2.0) | |
The battery | The battery type | Lithium ion, 14.8 V, 2.55 Ah |
Battery charging time | 3 hours, | |
The battery discharge time | 8 hours (under normal circumstances) | |
Ac adapter | The input voltage | 100 VAC to 240 VAC |
Input frequency | 50/60 Hz | |
The operating system | 6.0 the Core WinCE | |
Language support | English, French, German, Italian, Japanese, Spanish, Portuguese, simplified Chinese | |
Warranty period | Three years, | |
Environmental indicators | ||
Working temperature | 0 ° C to 50 ° C (32 ° F to 122 ° F) | |
Storage temperature | - 20 ° to 60 ° C (C - 4 ° F to 140 ° F) | |
Working humidity | Between 10% and 95% relative humidity (no condensation) | |
Accredited institution | CHINA RoHS, CSA, CE, C TICK, WEEE | |
Electromagnetic compatibility | EN 61326-1:6, EN 61010-1:01 version 2. | |
Sensor technology specifications | ||
The sensor type | The accelerometer | |
The sensitivity | MV / 100 g (+ / - 5%, 25 ° C) | |
Acceleration range | 80 g peak | |
Amplitude nonlinearity | 1% | |
Frequency response | Z | 2 to 7000 Hz + 3 db |
The X, Y, | 2 to 5000 Hz + 3 db | |
The power supply requirements (IEPE) | 18 VDC to 30 VDC, mA 2 to 10 mA | |
Offset output voltage | 12 VDC | |
grounding | Enclosure grounding | |
Sensor design | PZT ceramic/shear type | |
The shell material | 316 l stainless steel | |
Fixed a | 10-32 capacitive hex head screws, 2 extremely rare earth magnets (48 pounds drawing strength) | |
Output connector | Four needles, M12 | |
Match the connector | M12 - F4D | |
Nonvolatile memory | TEDS 1451.4 compatible | |
Vibration limit | 500 g peak | |
Impact threshold | 5000 g peak | |
Electromagnetic sensitivity, equivalent g | 100 micrograms/gaussian | |
The sealing performance | Air tight seal | |
Temperature range | - 50 ° C to 120 ° C (- 58 ° F to 248 ° F) plus or minus 7% | |
Warranty period | 1 year | |
Tachometer technical indicators | ||
Size (deep x wide) | 2.86 x 12.19 cm (1.125 x 4.80 in) | |
The weight of the | 96 g (3.4 oz), including the cables | |
The power supply | By the 810 vibration power supply | |
detection | Class 2 laser diode | |
range | 6.0 to 99999 RPM | |
precision | 6.0 to 5999.9 RPM | Plus or minus 0.01% and + 1 |
5999.9 to 99999 RPM | Plus or minus 0.05% and + 1 | |
The resolution of the | 0.1 RPM | |
Effective range | 1 cm to 100 cm (0.4 to 39.27 in) in | |
The response time | 1 s (> 60 RPM) | |
controls | Measuring the transparent on/off button | |
interface | The Mini DIN 6 needle | |
The length of the cable | 50 cm (19.586 in) | |
Warranty period | 1 year | |
Tachometer attachment | Reflective tape | 1.5 x 52.5 cm (0.59 x 20.67 in) |
Viewer PC software | ||
The minimum hardware requirements | 1 GB of RAM | |
Operating system requirements | Windows XP, Vista |
Mode雷竞技appl: Fluke 810 vibration
The vibration diagnosis instrument
The vibration diagnosis instrument include:
- Vibration diagnostic instrument with diagnostic function
- Triaxial accelerometers installed, magnets, with adhesive pads suite, accelerometer quick disconnect the cable
- Laser tachometer and storage pocket
- Intelligent battery with cable and adapter
- With adjustable straps and hand
- Viewer PC software
- Mini USB to USB cable
- Getting started guide, quick reference guide with diagram, user manual CD
- Carry bag