China

雷竞技appFluke 51 - II single channel contact thermometer

  • 雷竞技appFluke II 51 Single Input Digital Thermometer 1

The main features

  • Lab grade and high precision accuracy (+ / 0.05% + 0.3 ° C)
  • Wide temperature range (200 ° C to 1372 ° C)
  • Compatible with J, K, E, T four types of thermocouple
  • With relative time tag of maximum, minimum, average
  • Widescreen double row shows clear reading
  • A variety of optional type probe
  • The small hand-held portable
  • Dust impact protection shell

Produc雷竞技appts overview: Fluke 51 - II single channel contact thermometer

雷竞技appFluke 51 - II contact thermometer (thermocouple thermometer) has a laboratory level high precision accuracy (+ / 0.05% + 0.3 ° C), stable and reliable readings.雷竞技appFluke 51 - II for single channel thermometer, with a 80 pk - 1 K type thermocouple, and a variety of temperature measuring probe is optional.Small size, portable design, suitable for a variety of temperature measurement.Widescreen display, operation is simple, and can satisfy you the demand of fast accurate temperature measurement.

Produc雷竞技appt specifications: Fluke 51 - II single channel contact thermometer

Technical indicators
The temperature accuracy
Above 100 ° C: J, K, T, E, plus or minus 0.05% + 0.3 ° C *
R and S type: plus or minus 0.05% + 0.4 ° C *
Below 100 ° C: J, K, E type: plus or minus 0.20% + 0.3 ° C *
T: + / 0.50% + 0.3 ° C
Temperature range
J: - 210 ° C to 1200 ° C
K type: - 200 ° C to 1372 ° C
T: - 250 ° C to 400 ° C
E: - 150 ° C to 1000 ° C
0 ° C to 1767 ° C *
Temperature scale
ITS - 90.
Applicable standards
NIST - 175.
Display resolution
0.1 ° C, 0.1 K < 1000
1 ° C, 1 K > = 1000
note
* On雷竞技apply Fluke II B 53 and 54 II B type thermometer can measure N, R and S type thermocouple
Environmental parameters:
Working temperature
- 10 ° C to 50 ° C
Storage temperature
To 40 ° to 60 ° C C
Humidity (no condensation)
Between 0% and 90%;0 ° to 35 ° C C
Between 0% and 70%;0 ° C to 50 ° C
Security technology parameters
The overvoltage category
CSA C22.2 No. 1010.1, 1992;EN 61010 Amendments 1 and 2
Accredited institution
CE, CSA, TUV (awaiting approval)
Machinery and general parameters
size
173 mm x 86 mm L W x 38 mm
The weight of the
400 g
The battery
3 AA battery model, typical battery life of 1000 hours

Sing雷竞技apple channel models: Fluke 51 - II contact thermometer

雷竞技appFluke 51 II
Single input digital thermometer includes:
  • Anti-collision protective sleeve
  • A 80 pk - 1 bead type probe thermocouple