雷竞技appFluke 53 - single channel record type IIB contact thermometer

  • 雷竞技appFluke 53 II Single Input Digital Thermometer with Data Logging
  • 雷竞技appFluke 53 II Single Input Digital Thermometer with Data Logging

The main features

  • Lab grade and high precision accuracy (+ / 0.05% + 0.3 ° C)
  • Wide temperature range (200 ° C to 1372 ° C)
  • Compatible with J, K, E, T, N, R, S seven types of thermocouple
  • With relative time tag of maximum, minimum, average
  • 500 data storage with real time markers
  • The automatic recording data can be set a time interval
  • Widescreen double row shows clear reading
  • A variety of optional type probe
  • The small hand-held portable
  • Dust impact protection shell
  • Can be set deviation compensation
  • By infrared 雷竞技appUSB cable and FlukeView Forms (FVF - SC2) connected to the computer and software download analysis data (FVF - SC2 software and connecting cables are optional)

Produc雷竞技appts overview: Fluke 53 - single channel record type IIB contact thermometer

雷竞技appFluke 53 - IIB contact thermometer (thermocouple thermometer) has a laboratory level high precision accuracy (+ / 0.05% + 0.3 ° C), stable and reliable readings.雷竞技appFluke 53 - IIB for single channel thermometer, with a 80 pk - 1 K type thermocouple, and a variety of optional temperature probe.Small size, portable design, suitable for a variety of temperature measurement.Widescreen display, operation is simple, and can satisfy you the demand of fast accurate temperature measurement.雷竞技appFluke 53 - IIB also have 500 point data storage and record function, and can through software (optional) and cable (optional) connected to the computer for data download and analysis.

Produc雷竞技appt specifications: Fluke 53 - single channel record type IIB contact thermometer

The technical specification
The temperature precision Above 100 ° C J, K, T, E and N type: plus or minus 0.05% + 0.3 ° C creates
R and S type: plus or minus 0.05% + 0.4 ° C creates
Below 100 ° C J, K, E and N type: plus or minus 0.20% + 0.3 ° C creates
T: + / 0.50% + 0.3 ° C
The temperature J: - 210 ° C to 1200 ° C
K type - 200 ° C to 1372 ° C
T - 250 ° C to 400 ° C
E - 150 ° C to 1000 ° C
N Creates - 200 ° C to 1300 ° C
R and S type 0 ° C to 1767 ° C creates
Temperature scale ITS - 90.
Applicable standards NIST - 175.
Display resolution 0.1 ° C, 0.1 K < 1000
1 ° C, 1 K p 1000
1. Onl雷竞技appy the Fluke II B 53 and 54 II B type thermometer can measure N, R and S type thermocouple.
Environmental indicators
Working temperature - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
Humidity (no condensation) Between 0% and 90%;0 ° to 35 ° C C
Between 0% and 70%;0 ° C to 50 ° C
Safety specifications
The overvoltage category CSA C22.2 No. 1010.1, 1992;EN revision 1, 2, 61010
Accredited institution CE, CSA, TUV (awaiting approval)
The mechanical and general specifications
Size (length x width x height) 173 x 86 x 38 mm
The weight of the 400 g
The battery 3 AA battery model, typical battery life of 1000 hours

Mode雷竞技appl: Fluke 53 - single channel record type IIB contact thermometer

雷竞技appFluke 53 - II B
Single input digital thermometer, with functions of data records, including
  • Anti-collision protective sleeve
  • A 80 pk - 1 bead type probe thermocouple