China

雷竞技appHigh temperature infrared thermometer Fluke 572-2

  • 雷竞技appFluke 572-2 High - Temperature Infrared Thermometer
  • 雷竞技appFluke 572-2 High - Temperature Infrared Thermometer

The main features

雷竞技appFluke 572-2 strong and durable, easy to use, in line with the ergonomics design, even in harsh industrial, electrical and mechanical environment also can be used as usual.

  • Measuring temperature range is - 30 ° C to 900 ° C (22 ° F to 1652 ° F) -
  • 60:1. The distance from the spot rate and double laser aiming system, can quickly pinpoint targets
  • Multilingual interface (user)
  • The current temperature and maximum, minimum, average temperature and temperature display
  • Compatible with the standard of mini connector type K thermocouple, thermocouple is including belt and installed
  • Adjustable emissivity and predefined emission rate
  • Infrared temperature and thermocouple temperature shown in display with back light
  • The latest reading maintained (20 seconds)
  • High and low temperature alarm
  • Data store and view (99 set of data can be stored)
  • The tripod mounting base
  • 12 or 24 when the system clock
  • USB 2.0 computer interface lines
  • 雷竞技appFlukeView ® software form record
  • 2 years warranty

Produc雷竞技appts overview: Fluke 572-2 high temperature infrared thermometer

雷竞技appFluke 572-2 high temperature infrared thermometer is suitable for the industrial environment of high temperature.Whether in the public power grid, metal refining and smelting, glass, cement or petrochemical industry environment, the new 572-2 are you reliable testing tool, let you can be anywhere in the environment of high temperature and high distance spot than for required for accurate measurement.

Through the int雷竞技appuitive user interface and soft key menu, Fluke 572-2 to make complex measuring process is simple.Just use some button, can realize quick navigation, adjust the emissivity, start recording data and alarm switch.

Produc雷竞技appt specifications: Fluke 572-2 high temperature infrared thermometer

The infrared measurement
Infrared temperature range - 30 ° C to 900 ° C (22 ° F to 1652 ° F) -
Infrared precision (ambient temperature for 23 ° C + 2 ° C for geometric correction) Acuity 0 ° C: plus or minus 1 ° C or + / - 1% of the readings, take larger value
P - 10 ° C to < 0 ° C: plus or minus 2 ° C
< - 10 ° C: plus or minus 3 ° C
32 ° F or higher: plus or minus 2 ° F or + / - 1% of the reading, take larger value
14 ° F or higher to < 32 ° F: plus or minus 4 ° F
< 14 ° F: plus or minus 6 ° F
Infrared repeatability Plus or minus 0.5% of reading or plus or minus 0.5 ° C (+ / - 1 ° F), take larger value
Display resolution 0.1 ° C / 0.1 ° F
Distance: spot 60:1 (in energy calculation is 90%)
The minimum spot diameter 19 mm
The laser target Offset double laser, the output < 1 mW
Spectral response 8 microns to 14 microns
Response time (95%). < 500 ms
emissivity 0.10 to 1.00 digital adjustable (step 0.01) or a built-in common material list
Contact measurement method
K type thermocouple type temperature range - 270 ° C to 1372 ° C (454 ° F to 2501 ° F)
K type thermocouple input accuracy (ambient temperature is 23 ° C + 2 ° C) < - 40 ° C: plus or minus (1 ° C + 0.2 ° / 1 ° C)
To 40 ° C or higher: 1% plus or minus or plus or minus 1 ° C, take larger value
< - 40 ° F: - (2 ° F + 0.2 ° / 1 ° F)
To 40 ° F or higher: 1% plus or minus or plus or minus 2 ° F, take larger value
K type thermocouple 0.1 ° C / 0.1 ° F
K type thermocouple repeatability Plus or minus 0.5% of reading or plus or minus 0.5 ° C (+ / - 1 ° F), take larger value
Measurement options
High/low temperature alarm Can hear the sirens, and there are two kinds of color instructions
Maximum/minimum/average/deviation is
Can the Celsius scale of mutual conversion and the Fahrenheit scale is
backlight Normal brightness and brightness level, and is suitable for super brightness dark environment
The probe input K type thermocouple show probe and infrared temperature at the same time
The trigger lock is
Data is stored 99 points
display Lattice 98 x 96 pixels, with functional menu
communication USB 2.0
K type thermocouple technical specification
Range (bead detector) To 40 ° C to 260 ° C (to 40 ° F to 500 ° F)
precision In 0 ° C to 260 ° C (32 ° F to 500 ° F) within the scope of + / - 1.1 ° C (+ / - 2.0 ° F).From to 40 ° C to 0 ° C (to 40 ° F to 32 ° F), the typical values within 1.1 ° C (2.0 ° F)
The length of the cable 1 m (40) in long K type thermocouple cables, equipped with standard miniature thermocouple connector and bead end
General technical specification
Safety and compliance IEC 60825-1
The FDA laser the second category
IEC 61326-1
CE compliance
CMC is # 01120009
Working temperature 0 ° C to 50 ° C (32 ° F to 122 ° F)
Storage temperature - 20 ° to 60 ° C (C - 4 ° F to 140 ° F)
Relative humidity 30 ° C (86 ° F), relative humidity is 10% to 90%, with no condensation
Work at an altitude of An average elevation of 2000 m
The weight of the 0.322 kg (0.7099 lb)
The power supply 2 AA batteries
Battery life Eight hours when using laser and backlight;In 100% space factor (thermometer continuously open) condition, do not use the laser and backlight 100 hours

Type雷竞技app: high temperature infrared thermometer Fluke 572-2

Fluke 572-2

Hand-held infrared thermometer: fluke 572 infrared digital thermometer

The high temperature infrared thermometer

Include:

  • K type thermocouple bead probe
  • Durable hard carry bag
  • USB 2.0 computer interface lines