The main features
雷竞技appFluke 62 MAX + Infrared Thermometer
- Dust and water - resistant: IP54 rated.
- Rugged: 3 - meter (9.8 - foot) drop *.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Short to spot: now.
- Dual lasers: Identifies the area to be measured.
- Large, backlit display: top service data easier to read, even in dark areas.
雷竞技appFluke T + PRO Voltage and Continuity Tester
- Three forms of AC/DC voltage detection, light, sound, and vibration.
- Extra heavy - duty, replaceable test leads.
- CAT 600 IV, CAT III 1000 V safety rated.
- Continuity beeper.
雷竞技appFluke 1 ac - II VoltAlert ™ Non - Contact Voltage Detector
- Voltbeat ™ technology and continuous self - test, so always know it 's working.
- Upon detection of voltage, tip glows and beeper contributor.
- Voltage detection of 90 to 1000 VAC.
- The CAT IV 1000 V for added protection.
雷竞技appFluke C115 Soft Case
- Lightweight soft case to dojo.provide optimal protection and accessory storage.
Produc雷竞技appts overview: Fluke 62 MAX + / T + 1 ac PRO/IR Thermometer, T + PRO Voltage Continuity Tester and Voltage Detector Kit
The rugged 雷竞技appFluke 62 MAX + IR thermometer teamed with The full featured T + PRO voltage continuity tester and The easy - to - use 1 - AC - II non - contact voltage detector, has everything you need to solve The problems quickly. Use The IR thermometer to test for overheating in electrical devices, next use The electrical test tools to learn more about The problem safely and conveniently.
Produc雷竞技appt specifications: Fluke 62 MAX + / T + 1 ac PRO/IR Thermometer, T + PRO Voltage Continuity Tester and Voltage Detector Kit
雷竞技appFluke 62 MAX + Infrared Thermometer
Specifications | ||
Temperature range | - 30 ° C to 650 ° C (22 ° F to 1202 ° F) - | |
Accuracy | + / - 1.0 ° C or plus or minus 1.0% of reading, whichever is greater - 10 ° C to 0 ° C: + / - 2.0 - 30 ° C to - 10 ° C: + / - 3.0 |
|
The Response time (95%). | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | Whoever (calculated at 90% energy) | |
The Display resolution | 0.1 ° C (0.2 ° F) | |
Repeatability of readings | Plus or minus 0.5% of reading or < plus or minus 0.5 ° C (1 ° F), whichever is greater | |
The Power | AA ' | |
'life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
The Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0 ° C to 50 ° C (32 ° F to 122 ° F) | |
Storage temperature | - 20 ° to 60 ° C (C - 4 ° F to 140 ° F), (without ') | |
Operating humidity | 10% to 90% RH non - condensing at 30 ° C (86 ° F) | |
Operating led | 2000 meters above mean sea level | |
Storage led | 12000 meters above mean sea level | |
The IP rating | IP 54 per IEC 60529 | |
The Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:6 now EN 61326-06 | |
Standards and agency approval | The Compliance | EN/IEC 61010-1:2001 |
Laser safety | The FDA and EN 60825-1 Class II |
雷竞技appFluke T + PRO Electrical Testers
Specifications | ||
Temperature | Operating | 55 ° to 10 ° C to C (14 ° F to 131 ° F) |
Storage | - 30 ° to 60 ° C (C - 22 ° F to 140 ° F) | |
Relative humidity | 0 ° C to 30 ° C (32 ° F to 86 ° F) : 90% | |
30 ° C to 40 ° C (86 ° F to 104 ° F) : 75% | ||
40 ° C to 50 ° C (104 ° F to 122 ° F) : 45% | ||
led | Operating | 2000 m (approx. 6561.6 ft) |
Storage | 10000 m (approx. 32808 activity ft) | |
'the type/life | AAA (2);40 hours | |
Shock, vibration | Sinusoidal vibration per MIL - PRF - 28800 - f for a Class 2 instrument | |
Safety | ISA - 82.02.01 Mod (IEC 61010-1), Second Edition, CAN/CSA C22.2 No. 61010-1 Second Edition, IEC 61010-1 III / 600 V to 1000 V CAT CAT IV | |
The Compliance to NFPA 70 e1 | ||
AC bandwidth | 45 Hz to 66 Hz | |
Maximum working voltage | 1000 V AC/DC | |
Maximum measurable voltage | 600 V AC/DC | |
Duty cycle | Indefinitely for voltages of up to 240 V | |
For voltages between 240 V and 600 V, the duty cycle is 30 s 300 s on/off | ||
For voltages above 240 V, the tester must connect to a voltage source only For a MAXIMUM of 30 s and then disconnect For a MINIMUM of 300 s | ||
Voltage hazard LED | LEDs turn on at voltages > 30 V AC/DC + / - 35% | |
LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V | |
LED voltage indication levels for Canadian version | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V | |
LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% | |
LCD accuracy on T + PRO only | The AC voltage | Plus or minus 3% (RDG who + 2) |
The DC voltage | Plus or minus 2% (RDG who + 2) | |
To hold | Plus or minus 5% (RDG + 3 who) | |
The LCD resolution | For 0.1 V voltages < 50 V, 1 V for voltages 50 V or higher 0.01 k Ω for hold measurement (for T + PRO Only) |
|
GFCI test current | 100 V - 150 - V @ 6 mA - 9 mA AC, 150 V - 240 - V < 12 mA | |
Standard input the test current | < 5 mA | |
The Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm) | |
Weight | 9.9 oz (0.28 kg) | |
1. The When informs the properly per Article 110.9 the Use of Equipment (A) the Test Instruments and Equipment. |
雷竞技app1 ac - II VoltAlert Fluke
Specifications | ||
Operating principle | Senses the steady state electrostatic fi eld produced by ac voltage through insulation without requiring the contact to the bare conductor. A red glow at the tip and A beeping noise (if not switched OFF) are the presence of voltage. | |
Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on the model, 45 Hz to 405 Hz.Also a 20 V to 90 V control circuit model | |
The Detector tip style | Blade or round, depending on the model | |
Light source | One high intensity red leds | |
Agency approvals | C CSA us, CE, c - Tick | |
Safety rating | 1000 V, the CAT IV | |
The IP rating | IP 40 | |
Operating temperature | - 10 ° C to 50 ° C | |
Operating humidity ranges | 0% to 95% | (0 ° to 30 ° C) C |
0% to 75% | (30 ° C to 40 ° C) | |
0% to 45% | (40 ° C to 55 ° C) | |
Operating led | 3000 meters | |
Batteries | 2 AAA alkaline batteries included | |
The Product does not respond to the random electrostatic discharge. |
Mode雷竞技appl: Fluke 62 MAX + / T + 1 ac PRO/IR Thermometer, T + PRO Voltage Continuity Tester and Voltage Detector Kit
雷竞技appFluke 62 MAX + T + PRO / 1 / ac
雷竞技appFluke 62 MAX + / T + 1 ac PRO/IR Thermometer, T + PRO Voltage Continuity Tester and Voltage Detector Kit
Includes:
- 雷竞技appFluke 62 MAX + IR Thermometer
- 雷竞技appFluke T + Pro Electrical Tester
- 雷竞技appFluke 1 ac II VoltAlert Voltage Detector
- C115 Soft Case