雷竞技appMax + / 1 Fluke T5-600/62 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit
The main features
雷竞技appFluke T5 Voltage, Continuity and Current Testers.
- Automatically measures volts, AC volts DC and with precise digital resolution.
- 1000 Ω Displays to hold to.
- Easy and accurate OpenJaw ™ current measurement.
- Continuity beeper.
- Rugged enough to withstand a 10 ft (3 m) drop.
- 600 V model.
- Auto off mode to conserve 'life.
- AC current.
- The Display to hold.
- All inputs of the T5-600 are protected to CAT III 600 v. EN61010-1 UL, CSA and VDE listed.
雷竞技appFluke 62 MAX +. Small in size. Big on toughness.
- Dust and water - resistant: IP54 rated.
- Rugged: 3 m (9.8 ft) drop *.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Short to spot: now.
- Dual lasers: Identifies the area to be measured.
- Large, backlit display: top service data easier to read, even in dark areas.
- C115 Deluxe soft their case with shoulder strap.
Produc雷竞技appts overview: Fluke T5-600/62 Max + / 1 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit
This kit is designed to help electricians and HVAC technicians of solve the problems quicker. Test first for overheated electrical devices using an IR thermometer.Then use electrical test tools to find out more about the problem.
Produc雷竞技appt specifications: Fluke T5-600/62 Max + / 1 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit
雷竞技appFluke T5-600 Voltage, Continuity and Current Tester
Specifications | ||
Jaw opening | 12.9 mm (0.5 in) | |
Max wire size | 1/0 THHN cable | |
The Current range AC RMS | 0 to 100.0 A | |
Accuracy of AC current (50/60 Hz) | 3% plus or minus 3 counts | |
AC Response | Averaging | |
Voltage range AC | 0 to 600 V | |
Accuracy of AC voltage | 1.5% plus or minus 2 counts | |
Voltage range of DC | 0 to 600 V | |
Accuracy DC voltage | The count 1% plus or minus 1 | |
To hold the range | 0 to 1000 Ω | |
Continuity beeper threshold | On the at < 25 Ω, off the at > 400 Ω | |
Volts indicator LED threshold | Guaranteed on by 30 V AC | |
Environmental Specifications | ||
Operating temperature | - 10 ° C to 50 ° C | |
Storage temperature | - 30 ° to 60 ° C C | |
Humidity (without condensation) | 0% to 95% (5 ° to 30 ° C C);0% to 75% (30 ° C to 40 ° C); 0% to 45% (40 ° C to 50 ° C) |
|
Dust/water to hold | Yes | |
Operating led | 2000 meters Max | |
Temperature coefficient | 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C) | |
Safety Specifications | ||
Measurement Category | IEC 61010-2-032, IEC61010-2-033: the CAT III 600 V, 100 A ac | |
Agency approvals | CSA and TUV | |
Maximum voltage | 600 V between any terminal and earth ground | |
Mechanical and General Specifications | ||
The Size | 51 x 30.5 x 203 mm | |
Weight | 300 g | |
giant | Two years - | |
'life | 200 hour any zinc chloride, 400 hour alkaline | |
'type | 2 x AA | |
Low 'indicator | Yes | |
The Current sensor opening | The 12.9 mm | |
Calibration cycle | 1 year | |
The Test leads | The Type | Heavy duty, flexible leads rated for the use of 1000 V. Field replaceable leads the terminate male shrouded in banana plugs |
The Probes | One red and One black. Detachable Slim - Reach ™ probe tips |
|
Styles | TP1 Slim Reach ™ test brobes | |
Safety Specifications | ||
Safety | CAT IV 600 V, the CAT III, 1000 V | |
Maximum voltage | 1000 V AC RMS from earth to the ground, in the compliance with EN61010 |
雷竞技appFluke 62 MAX + Infrared Thermometer
Specifications | ||
Temperature range | - 30 ° C to 650 ° C (22 ° F to 1202 ° F) - | |
Accuracy | + / - 1.0 ° C or plus or minus 1.0% of reading, whichever is greater - 10 ° C to 0 ° C: + / - 2.0 - 30 ° C to - 10 ° C: + / - 3.0 |
|
The Response time (95%). | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | Whoever (calculated at 90% energy) | |
The Display resolution | 0.1 ° C (0.2 ° F) | |
Repeatability of readings | Plus or minus 0.5% of reading or < plus or minus 0.5 ° C (1 ° F), whichever is greater | |
The Power | AA ' | |
'life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
The Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0 ° C to 50 ° C (32 ° F to 122 ° F) | |
Storage temperature | - 20 ° to 60 ° C (C - 4 ° F to 140 ° F), (without ') | |
Operating humidity | 10% to 90% RH non - condensing at 30 ° C (86 ° F) | |
Operating led | 2000 meters above mean sea level | |
Storage led | 12000 meters above mean sea level | |
The IP rating | IP 54 per IEC 60529 | |
The Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:6 now EN 61326-06 | |
Standards and agency approval | The Compliance | EN/IEC 61010-1:2001 |
Laser safety | The FDA and EN 60825-1 Class II |
Mode雷竞技appl: Fluke T5-600/62 Max + / 1 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit
雷竞技appFluke T5 - MAX + 600/62
雷竞技appMax + / 1 Fluke T5-600/62 ac II IR Thermometer, Electrical Tester and Voltage Detector Kit