China

Ti200 a3001 FC iFlex ® suite

  • 雷竞技appFluke Ti200 a3001 FC iFlex ® Kit
  • 雷竞技appFluke Ti200 a3001 FC iFlex ® Kit
  • 雷竞技appFluke Ti200 a3001 FC iFlex ® Kit
  • 雷竞技appFluke Ti200 a3001 FC iFlex ® Kit
Has been discontinued

The main features

Ti200 thermal imager features below:

  • Proprietary LaserSharp ® autofocus system to ensure accurate shooting focus images
  • Using patent IR - Fusion ® technology and AutoBlend ™ model accurate Fusion visible light image and infrared image (invention patent, patent no. 2005800472355)
  • Com雷竞技apppatible with Fluke Connect ®
  • Through the wireless image transmission, faster transfer directly to your PC, Apple ® iPhone ® or the ®
  • Rugged 640 x480 resolution capacitive touch screen, can be carried out fast navigation menu
  • Use the IR - PhotoNotes ™ annotation system, additional digital image capture, to show the position or more detailed information on site
  • More advanced display output options, through to the PC or high resolution monitor for video streaming transmission (USB and HDMI) for details
  • By recording and comments, can save the additional detailed information in the image file
  • Optional replaceable lens has greater flexibility in other applications
  • The intelligent battery rechargeable and field replacement, can display power level LED display, can provide excellent flexibility
  • 5 million pixels industrial digital camera performance, can provide high-definition image quality
  • Built-in SmartView ® and SmartView mobile software application analysis and report

3000 FC wireless multimeter to provide:

  • Ac and dc voltage measurement, up to 1000 V
  • Ac and dc current is 0.01 mA resolution
  • Connectivity, resistance, diode testing, capacitance and frequency measurement
  • Minimum/maximum record
  • The CAT III 1000 V, the CAT IV 600 V;IP54

Current through iFlex ™ wireless module, you will be able to cope with tough wire size, or into a narrow space and make it easier to wire access.A3001 FC has:

  • One (1) a true effective value (true - RMS) flexible galvanometer
  • One (1) a iFlex i2500-10 flexible current probe
  • Maximum 2500 A ac measurement
  • Can be used as an independent instrument or as part of the system
  • Record function, used to record and save as many as 65000 readings
  • Surge function
  • Magnetic hanging belt
This product has been discontinued or reclassified

Products overview: Ti200 a3001 FC iFlex ® suite

When Ti200 th雷竞技appermal imager and the Fluke Connect ® application and Fluke a3001FC iFlex suite when used in combination, will present a powerful solution for you, can be directly from the scene quickly identify and diagnose potential problems.All two inspec雷竞技apption data can be incorporated into the Fluke Connect application, and can be anywhere at any time and any team member instantly share your test results.Begin immediately to save time and improve production efficiency.

With LaserSharp ® autofo雷竞技appcus system Fluke products portfolio, Ti200 thermal imager is one of only three thermal imager, ensures reliable shooting focus image for you.Every time if there is no accurate image focus, temperature measurement deviation could be as high as 20 degrees, so it's easy to miss a potential problem.LaserSharp autofocus system can accurately focus on target.In front of the focusing laser is used to calculate the system and the distance between the target.The red laser points on an ongoing flaw detection equipment, and then pull and release the trigger, to get a clear picture of perfect focus.Normal operation or shutdown.Your result is very important.

Product specifications: Ti200 a3001 FC iFlex ® suite

雷竞技appFluke Ti200 infrared thermal imager

Detailed technical indicators
The temperature
Temperature measurement range
(below - 10 ° C not calibration)
- 20 ° C to + 650 ° C (4 ° F to 1202 ° F) +
Temperature measurement precision Plus or minus 2 ° C or 2% (25 ° C, take readings larger value)
Screen emissivity correction Is (according to the number and form)
The screen reflection background temperature compensation There are
The screen transmission correction There are
Imaging performance
Image capture frequency 60 Hz refresh rate
The probe type 200 X 150 pixels focal plane array, the refrigeration type micro bolometer
Thermal degree (NETD) 30 ° C target temperature, 0.075 ° C (75 mK) or less
The total pixels 30000
The infrared spectral band 7.5 mu m to 14 microns (long)
Video camera (visible light) Industrial performance, 5 million pixels
Standard infrared lens type
Field of view 17 ° 24 ° x
The spatial resolution (IFOV) 2.09 mRad
The minimum distance 15 cm (about 6 inches)
Optional telephoto infrared lens type
Field of view 12 ° x 9 °
The spatial resolution (IFOV) 1.05 mRad
The minimum distance 45 cm (about 18 inches)
Optional wide-angle infrared lens type
Field of view 34 ° 46 ° x
The spatial resolution (IFOV) 4.19 mRad
The minimum distance 15 cm (about 6 inches)
Focusing mechanism
LaserSharp ® laser af system There are
Advanced manual focus There are
Image display mode
The palette
standard Iron oxide red, blue and red, high contrast, amber, amber, hot metal, gray, gray
Super high Contrast (Ultra Contrast ™) Super iron oxide red, blue and red, high contrast, amber, amber, ultra hot metal, super gray, gray
Level and the span The scope and smooth level automatic adjustment and manual adjustment
Fast automatic switch between manual and automatic mode There are
Manual mode of fast automatic adjustment again There are
Minimum range (manual mode) 2.0 ° C (3.6 ° F)
The minimum range (automatic mode) 3.0 ° C (5.4 ° F)
IR - Fusion ® information
Picture in picture (PIP) There are
Full screen infrared There are
AutoBlend ™ mode There are
Color alarm (alarm temperature) High temperature, low temperature and isothermal (optional) user
Image capture, and data storage
Image capture, view, save mechanism Single hand image capture, view and save functions
A storage medium Micro SD memory card to keep, ram, USB function, connect via USB to computer directly to the download
The file format The radiation (. BMP or jpeg) or total radiation (. Is2)
The radiation survey (. BMP and. JPG) file without using the analysis software
Use SmartView ® software export file format BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF and TIFF
The memory view Thumbnail view navigation and viewing options
The function of the other to save time and improve productivity
Voice note Longest 60 seconds per image recording;Can playback view on thermal imager
IR - PhotoNotes ™ There are
WiFi connection Is connected to the PC, iPhone ®, the ®, through WiFi connection to the local area network (LAN) *
Text comment * There are
Video recording * Standard and radiation
Streaming video Through the USB to the computer and, through the HDMI to HDMI compatible screen
Com雷竞技apppatible with Fluke Connect Is provided (if any)
Automatically capture (temperature and interval) * There are
The remote control and operation (applicable to special and advanced application) no
General technical indicators
Working temperature - 10 ° C to 50 ° C (14 ° F to 122 ° F)
Storage temperature - 20 ° C to + 50 ° C (4 ° F to 122 ° F), without the battery
Relative humidity Between 10% and 95% with no condensation
Durable touch screen (capacitive) 8.9 centimeters (3.5 inches) diagonal, horizontal color VGA (640 x 480), LCD backlight
Control and regulation The user can choose temperature unit (° C / ° F)
Language selection
The date/time setting
Emissivity of choice
Reflective background temperature compensation
Transmittance correction
Users can choose the image on the hot and cold spots and center
Extensible/shrinkage measuring box with MIN - AVG - MAX (low - medium - high) three temperature
Color alarm
Users can choose the backlight set the graphics information display preferences
Graphic information display preferences
software SmartView ® and SmartView mobile applications - contains the complete analysis and reporting software
The battery All models are equipped with two intelligent charging lithium ion battery, battery levels through five lattice LED display instructions
Battery life Each battery pack can be continuous use four hours or more (assuming the LCD brightness is 50% and the average intensity of use)
Battery charging time 2.5 hours with
Battery charging communication Double groove ac battery charger (110 VAC to 220 VAC, 50/60 Hz) (attached), or in charge within the thermal imager.Enclosed is the ac power adapter.Optional 12 V car battery adapter.
Alternating current (ac) work Through the attached power supply (110 VAC to 220 VAC, 50/60 Hz) using an alternating current work to accompany the ac power adapter.
Energy saving The user can choose sleep and shutdown mode
Safety standards UL 61010-1:12 CAN/CSA - C22.2 No. 61010-1-12 of IEC 61010-1 version 3 (2010).
Electromagnetic compatibility EN 61326-1:06 IEC 61326-1:05
C Tick IEC/EN 61326-1
US the FCC 47, CFR part 15 B part B class
vibration G2/0.03 Hz (GRMS) 3.8, 2.5 g IEC 68-2-6
impact 25 g, IEC 68-2-29
drop Designed to withstand 2 meters (6.5 feet) of drop height (when using the standard lens)
Size (height x width x length) 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
Weight (including battery) 1.04 Kg (2.3 lb)
Shell protection grade IP54 (dustproof sealing protection, all-round waterproof)
Warranty period Two years (standard), can also be extended warranties.
Recommended by the calibration cycle Two years (assuming a normal operation and aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish
* by the firmware update coming soon.Available via the SmartView software users.

雷竞技appFluke 3000 FC series wireless multimeter

* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).

The provisions of the ac voltage range scope ranges from 1% to 100% range.
2. The full scale highest do not exceed 500 V the crest factor of 3, when 1000 V linear reduced to crest factor of 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading)
4. Do not over 107 V - Hz.Alternating current range have been designated as a range from 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.DC to 60 Hz DC or ac RMS
Ac voltage
Range creates/resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy of the squared34 45 Hz - 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All
Dc voltage, connectivity, resistance, diode test and capacitance
The mV Range/resolution 600.0 mV / 0.1 mV
precision 0.09% + 2
V Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
precision 0.09% + 2
0.15% + 2
))) Range/resolution Ω Ω / 1, 600
precision < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit.
Ω Range/resolution 600.0 Ω / 0.1 Ω
6.000 k Ω Ω / 0.001 k
60.00 k Ω Ω / 0.01 k
60.00 k Ω Ω / 0.1 k
600.0 k Ω Ω / 0.001 M
Ω 50.00 M / 0.01 M Ω
precision 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range/resolution 2.000 V / 0.001 V
precision 1% + 2
Including F Range/resolution 1000 nF / 1 nF
10.00 u F / 0.01 u F
100.0 u F / 0.1 u F
9999 mu F1 /1 u F
precision 1.2% + 2
10% of the typical
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2.
Ac and dc current
Ac amps
(45 Hz to 1 kHz)
Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 1.5% + 3
MA DC squared Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 0.5% + 3
1. All
frequency
Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Precision creates 0.1% + 1
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz.
The input features
Overload protection 1100 V RMS
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
Unbalanced Ω (1 k)
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Overload protection 1100 V RMS
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
Unbalanced Ω (1 k)
> 60 dB,
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Overload protection 1100 V RMS
Input impedance (nominal value) > 10 M Ω < 100 pF
Common mode rejection ratio
Unbalanced Ω (1 k)
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB
Norm inhibition At 50 Hz or 60 Hz greater than 60 dB
Open circuit voltage
Overload protection 1100 V RMS
Input impedance (nominal value) < 2.7 V DC
Full scale voltage to 6 M Ω
Full scale voltage 50 M Ω
< 0.7 V DC
< 0.9 V DC
Typical short-circuit current < 350 mA,
Overload protection 1100 V RMS
Input impedance (nominal value) < 2.7 V DC
Full scale voltage to 6 M Ω
Full scale voltage 50 M Ω
2.000 V dc
Typical short-circuit current < 1.1 mA
MA function
Overload protection 44/100 fuse, A, 1000 V, fuse
overload 600 mA overload for up to 2 minutes, at least 10 minutes to a halt
Minimum/maximum record accuracy
Dc function Duration of > 350 milliseconds for counting + 12 times of change.
Communication function + 40 times the count () to the change of time length > 900 mS.
General technical indicators
The highest voltage between any terminal and earthing 1000 V
Ω A input fuse protection 0.44 A (44/100 A, 440 mA), 1000 V quick f雷竞技appuse, Fluke specified components only
Display (LCD) Update rate 4 / SEC.
The volt, ampere, ohm 6000 times
frequency 10000 times
capacitance 1000 times
The battery type Three AA alkaline batteries, NEDA IEC LR6 15 a
Battery life At least 250 hours
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
The temperature The temperature - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
The temperature coefficient of The set accuracy 0.1 X () / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C)
From 0% to 75% (35 ° C to 40 ° C)
From 0% to 45% (40 ° C to 50 ° C)
At an altitude of At an altitude of 2000 m
Storage temperature 12000 m
Electromagnetic compatibility
EMI and RFI, EMC (EMC) and RF
EN 61326-1:6, EN 61326-2 - "06
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements
FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE
Meet safety standards The ANSI/ISA 61010-1 / (82.02.01) : 3rd edition
CAN/CSA C22.2 No. 61010-1-12:3rd edition
UL 61010-1:3
IEC/EN61010-1:10
certification CSA, the FCC, CE
Protection (IP) rating IP54
Pollution levels 2
Size (height x width x length) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
The weight of the 340 g (12 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appFluke a3001 FC iFlex ac current wireless module

Technical indicators
range 0.5 A - 2500 - A AC
The resolution of the 0.1 A
precision 3% + 5 (5 Hz - 500 Hz)
Crest factor (50 Hz / 60 Hz) 3.0 (1100 A)
2.5 (1400 A)
1.42 (2500 A)
C.F. > 2 increased by 2%
W/LCD backlight 3 1/2 level a
Data storage rate/intervals 1 second (minimum)/can be adjusted by PC or the front panel
The battery type 15 A, 2 AA, NEDA IEC LR6
Battery life 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of Increased by 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Working humidity 35 ° C in 90%
40 ° C in 75%
50 ° C in 45%
work At an altitude of 2000 m
Storage temperature 12000 m
Electromagnetic compatibility (EMC) EN 61326-1:6
Meet safety standards IEC 61010-1600 - V class / 1000 V class III, IV third edition
Security level The CAT IV III 1000 V 600 V, the CAT
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP42
Pollution levels 2
Jaw opening 25.4 cm (10) in the coil
Size (high x width x deep) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
The weight of the 0.22 kg (8 oz.)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appFluke Connect is not in all countries/regions are provided.

* not all models are available in all countries/regions.Please consult your local representative fluke.

©Fluke companies.All trademarks are the property of their respective owner.When buying is not attached to provide smart phones, wireless services and data package, etc.The first 5 GB free.Compatible models: running iOS 8 or higher version of the iPhone 4 s, and more advanced models;The device (using the iPhone architecture);Run Android 4.3 x or higher version of the Samsung Galaxy S4, and run Android ™ 4.4 x or higher version of the Samsung Galaxy S, Nexus 5, HTC One and One M8.Both Apple and Apple logo for the company in the United States and other countries/regions registered trademark.App Store is a service mark of apple, Google Play is Google the company's trademark.