The main features
Ti200 thermal imager features below:
- Proprietary LaserSharp ® autofocus system to ensure accurate shooting focus images
- Using patent IR - Fusion ® technology and AutoBlend ™ model accurate Fusion visible light image and infrared image (invention patent, patent no. 2005800472355)
- Com雷竞技apppatible with Fluke Connect ®
- Through the wireless image transmission, faster transfer directly to your PC, Apple ® iPhone ® or the ®
- Rugged 640 x480 resolution capacitive touch screen, can be carried out fast navigation menu
- Use the IR - PhotoNotes ™ annotation system, additional digital image capture, to show the position or more detailed information on site
- More advanced display output options, through to the PC or high resolution monitor for video streaming transmission (USB and HDMI) for details
- By recording and comments, can save the additional detailed information in the image file
- Optional replaceable lens has greater flexibility in other applications
- The intelligent battery rechargeable and field replacement, can display power level LED display, can provide excellent flexibility
- 5 million pixels industrial digital camera performance, can provide high-definition image quality
- Built-in SmartView ® and SmartView mobile software application analysis and report
3000 FC wireless multimeter to provide:
- Ac and dc voltage measurement, up to 1000 V
- Ac and dc current is 0.01 mA resolution
- Connectivity, resistance, diode testing, capacitance and frequency measurement
- Minimum/maximum record
- The CAT III 1000 V, the CAT IV 600 V;IP54
Current through iFlex ™ wireless module, you will be able to cope with tough wire size, or into a narrow space and make it easier to wire access.A3001 FC has:
- One (1) a true effective value (true - RMS) flexible galvanometer
- One (1) a iFlex i2500-10 flexible current probe
- Maximum 2500 A ac measurement
- Can be used as an independent instrument or as part of the system
- Record function, used to record and save as many as 65000 readings
- Surge function
- Magnetic hanging belt
Products overview: Ti200 a3001 FC iFlex ® suite
When Ti200 th雷竞技appermal imager and the Fluke Connect ® application and Fluke a3001FC iFlex suite when used in combination, will present a powerful solution for you, can be directly from the scene quickly identify and diagnose potential problems.All two inspec雷竞技apption data can be incorporated into the Fluke Connect application, and can be anywhere at any time and any team member instantly share your test results.Begin immediately to save time and improve production efficiency.
With LaserSharp ® autofo雷竞技appcus system Fluke products portfolio, Ti200 thermal imager is one of only three thermal imager, ensures reliable shooting focus image for you.Every time if there is no accurate image focus, temperature measurement deviation could be as high as 20 degrees, so it's easy to miss a potential problem.LaserSharp autofocus system can accurately focus on target.In front of the focusing laser is used to calculate the system and the distance between the target.The red laser points on an ongoing flaw detection equipment, and then pull and release the trigger, to get a clear picture of perfect focus.Normal operation or shutdown.Your result is very important.
Product specifications: Ti200 a3001 FC iFlex ® suite
雷竞技appFluke Ti200 infrared thermal imager
Detailed technical indicators | |
The temperature | |
Temperature measurement range (below - 10 ° C not calibration) |
- 20 ° C to + 650 ° C (4 ° F to 1202 ° F) + |
Temperature measurement precision | Plus or minus 2 ° C or 2% (25 ° C, take readings larger value) |
Screen emissivity correction | Is (according to the number and form) |
The screen reflection background temperature compensation | There are |
The screen transmission correction | There are |
Imaging performance | |
Image capture frequency | 60 Hz refresh rate |
The probe type | 200 X 150 pixels focal plane array, the refrigeration type micro bolometer |
Thermal degree (NETD) | 30 ° C target temperature, 0.075 ° C (75 mK) or less |
The total pixels | 30000 |
The infrared spectral band | 7.5 mu m to 14 microns (long) |
Video camera (visible light) | Industrial performance, 5 million pixels |
Standard infrared lens type | |
Field of view | 17 ° 24 ° x |
The spatial resolution (IFOV) | 2.09 mRad |
The minimum distance | 15 cm (about 6 inches) |
Optional telephoto infrared lens type | |
Field of view | 12 ° x 9 ° |
The spatial resolution (IFOV) | 1.05 mRad |
The minimum distance | 45 cm (about 18 inches) |
Optional wide-angle infrared lens type | |
Field of view | 34 ° 46 ° x |
The spatial resolution (IFOV) | 4.19 mRad |
The minimum distance | 15 cm (about 6 inches) |
Focusing mechanism | |
LaserSharp ® laser af system | There are |
Advanced manual focus | There are |
Image display mode | |
The palette | |
standard | Iron oxide red, blue and red, high contrast, amber, amber, hot metal, gray, gray |
Super high Contrast (Ultra Contrast ™) | Super iron oxide red, blue and red, high contrast, amber, amber, ultra hot metal, super gray, gray |
Level and the span | The scope and smooth level automatic adjustment and manual adjustment |
Fast automatic switch between manual and automatic mode | There are |
Manual mode of fast automatic adjustment again | There are |
Minimum range (manual mode) | 2.0 ° C (3.6 ° F) |
The minimum range (automatic mode) | 3.0 ° C (5.4 ° F) |
IR - Fusion ® information | |
Picture in picture (PIP) | There are |
Full screen infrared | There are |
AutoBlend ™ mode | There are |
Color alarm (alarm temperature) | High temperature, low temperature and isothermal (optional) user |
Image capture, and data storage | |
Image capture, view, save mechanism | Single hand image capture, view and save functions |
A storage medium | Micro SD memory card to keep, ram, USB function, connect via USB to computer directly to the download |
The file format | The radiation (. BMP or jpeg) or total radiation (. Is2) |
The radiation survey (. BMP and. JPG) file without using the analysis software | |
Use SmartView ® software export file format | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF and TIFF |
The memory view | Thumbnail view navigation and viewing options |
The function of the other to save time and improve productivity | |
Voice note | Longest 60 seconds per image recording;Can playback view on thermal imager |
IR - PhotoNotes ™ | There are |
WiFi connection | Is connected to the PC, iPhone ®, the ®, through WiFi connection to the local area network (LAN) * |
Text comment * | There are |
Video recording * | Standard and radiation |
Streaming video | Through the USB to the computer and, through the HDMI to HDMI compatible screen |
Com雷竞技apppatible with Fluke Connect | Is provided (if any) |
Automatically capture (temperature and interval) * | There are |
The remote control and operation (applicable to special and advanced application) | no |
General technical indicators | |
Working temperature | - 10 ° C to 50 ° C (14 ° F to 122 ° F) |
Storage temperature | - 20 ° C to + 50 ° C (4 ° F to 122 ° F), without the battery |
Relative humidity | Between 10% and 95% with no condensation |
Durable touch screen (capacitive) | 8.9 centimeters (3.5 inches) diagonal, horizontal color VGA (640 x 480), LCD backlight |
Control and regulation | The user can choose temperature unit (° C / ° F) |
Language selection | |
The date/time setting | |
Emissivity of choice | |
Reflective background temperature compensation | |
Transmittance correction | |
Users can choose the image on the hot and cold spots and center | |
Extensible/shrinkage measuring box with MIN - AVG - MAX (low - medium - high) three temperature | |
Color alarm | |
Users can choose the backlight set the graphics information display preferences | |
Graphic information display preferences | |
software | SmartView ® and SmartView mobile applications - contains the complete analysis and reporting software |
The battery | All models are equipped with two intelligent charging lithium ion battery, battery levels through five lattice LED display instructions |
Battery life | Each battery pack can be continuous use four hours or more (assuming the LCD brightness is 50% and the average intensity of use) |
Battery charging time | 2.5 hours with |
Battery charging communication | Double groove ac battery charger (110 VAC to 220 VAC, 50/60 Hz) (attached), or in charge within the thermal imager.Enclosed is the ac power adapter.Optional 12 V car battery adapter. |
Alternating current (ac) work | Through the attached power supply (110 VAC to 220 VAC, 50/60 Hz) using an alternating current work to accompany the ac power adapter. |
Energy saving | The user can choose sleep and shutdown mode |
Safety standards | UL 61010-1:12 CAN/CSA - C22.2 No. 61010-1-12 of IEC 61010-1 version 3 (2010). |
Electromagnetic compatibility | EN 61326-1:06 IEC 61326-1:05 |
C Tick | IEC/EN 61326-1 |
US the FCC | 47, CFR part 15 B part B class |
vibration | G2/0.03 Hz (GRMS) 3.8, 2.5 g IEC 68-2-6 |
impact | 25 g, IEC 68-2-29 |
drop | Designed to withstand 2 meters (6.5 feet) of drop height (when using the standard lens) |
Size (height x width x length) | 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in) |
Weight (including battery) | 1.04 Kg (2.3 lb) |
Shell protection grade | IP54 (dustproof sealing protection, all-round waterproof) |
Warranty period | Two years (standard), can also be extended warranties. |
Recommended by the calibration cycle | Two years (assuming a normal operation and aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish |
* by the firmware update coming soon.Available via the SmartView software users. |
雷竞技appFluke 3000 FC series wireless multimeter
* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).
The provisions of the ac voltage range scope ranges from 1% to 100% range.2. The full scale highest do not exceed 500 V the crest factor of 3, when 1000 V linear reduced to crest factor of 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading)
4. Do not over 107 V - Hz.Alternating current range have been designated as a range from 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.DC to 60 Hz DC or ac RMS
Ac voltage | |||
Range creates/resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
||
Accuracy of the squared34 | 45 Hz - 500 Hz | 1.0% + 3 | |
500 Hz to 1 kHz | 2.0% + 3 | ||
1. All | |||
Dc voltage, connectivity, resistance, diode test and capacitance | |||
The mV | Range/resolution | 600.0 mV / 0.1 mV | |
precision | 0.09% + 2 | ||
V | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
|
precision | 0.09% + 2 0.15% + 2 |
||
))) | Range/resolution | Ω Ω / 1, 600 | |
precision | < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit. | ||
Ω | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 k Ω Ω / 0.001 k 60.00 k Ω Ω / 0.01 k 60.00 k Ω Ω / 0.1 k 600.0 k Ω Ω / 0.001 M Ω 50.00 M / 0.01 M Ω |
|
precision | 0.5% + 2 0.5% + 1 1.5% + 3 |
||
Diode test | Range/resolution | 2.000 V / 0.001 V | |
precision | 1% + 2 | ||
Including F | Range/resolution | 1000 nF / 1 nF 10.00 u F / 0.01 u F 100.0 u F / 0.1 u F 9999 mu F1 /1 u F |
|
precision | 1.2% + 2 10% of the typical |
||
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2. | |||
Ac and dc current | |||
Ac amps (45 Hz to 1 kHz) |
Range creates/ resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|
precision | 1.5% + 3 | ||
MA DC squared | Range creates/ resolution | 60.00 mA / 0.01 mA 400.0 mA after / 0.1 mA |
|
precision | 0.5% + 3 | ||
1. All | |||
frequency | |||
Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz |
||
Precision creates | 0.1% + 1 | ||
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz. | |||
The input features | |||
Overload protection | 1100 V RMS | ||
Input impedance (nominal value) | > 10 M Ω < 100 pF | ||
Common mode rejection ratio Unbalanced Ω (1 k) |
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | ||
Norm inhibition | At 50 Hz or 60 Hz greater than 60 dB | ||
Overload protection | 1100 V RMS | ||
Input impedance (nominal value) | > 10 M Ω < 100 pF | ||
Common mode rejection ratio Unbalanced Ω (1 k) |
> 60 dB, | ||
Norm inhibition | At 50 Hz or 60 Hz greater than 60 dB | ||
Overload protection | 1100 V RMS | ||
Input impedance (nominal value) | > 10 M Ω < 100 pF | ||
Common mode rejection ratio Unbalanced Ω (1 k) |
In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB | ||
Norm inhibition | At 50 Hz or 60 Hz greater than 60 dB | ||
Open circuit voltage | |||
Overload protection | 1100 V RMS | ||
Input impedance (nominal value) | < 2.7 V DC | ||
Full scale voltage to 6 M Ω Full scale voltage 50 M Ω |
< 0.7 V DC < 0.9 V DC |
||
Typical short-circuit current | < 350 mA, | ||
Overload protection | 1100 V RMS | ||
Input impedance (nominal value) | < 2.7 V DC | ||
Full scale voltage to 6 M Ω Full scale voltage 50 M Ω |
2.000 V dc | ||
Typical short-circuit current | < 1.1 mA | ||
MA function | |||
Overload protection | 44/100 fuse, A, 1000 V, fuse | ||
overload | 600 mA overload for up to 2 minutes, at least 10 minutes to a halt | ||
Minimum/maximum record accuracy | |||
Dc function | Duration of > 350 milliseconds for counting + 12 times of change. | ||
Communication function | + 40 times the count () to the change of time length > 900 mS. | ||
General technical indicators | |||
The highest voltage between any terminal and earthing | 1000 V | ||
Ω A input fuse protection | 0.44 A (44/100 A, 440 mA), 1000 V quick f雷竞技appuse, Fluke specified components only | ||
Display (LCD) | Update rate | 4 / SEC. | |
The volt, ampere, ohm | 6000 times | ||
frequency | 10000 times | ||
capacitance | 1000 times | ||
The battery type | Three AA alkaline batteries, NEDA IEC LR6 15 a | ||
Battery life | At least 250 hours | ||
Radio frequency communication | The 2.4 GHZ ISM band | ||
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters | |
, gypsum board wall | As far as 6.5 m | ||
Wall, concrete, or steel electric shell | As far as 3.5 m | ||
The temperature | The temperature | - 10 ° C to 50 ° C | |
Storage temperature | To 40 ° to 60 ° C C | ||
The temperature coefficient of | The set accuracy 0.1 X () / ° C (18 ° C or > < 28 ° C) | ||
Relative humidity | From 0% to 90% (0 ° C and 35 ° C) From 0% to 75% (35 ° C to 40 ° C) From 0% to 45% (40 ° C to 50 ° C) |
||
At an altitude of | At an altitude of | 2000 m | |
Storage temperature | 12000 m | ||
Electromagnetic compatibility EMI and RFI, EMC (EMC) and RF |
EN 61326-1:6, EN 61326-2 - "06 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE |
||
Meet safety standards | The ANSI/ISA 61010-1 / (82.02.01) : 3rd edition CAN/CSA C22.2 No. 61010-1-12:3rd edition UL 61010-1:3 IEC/EN61010-1:10 |
||
certification | CSA, the FCC, CE | ||
Protection (IP) rating | IP54 | ||
Pollution levels | 2 | ||
Size (height x width x length) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | ||
The weight of the | 340 g (12 oz) | ||
Warranty period | Three years, | ||
Is雷竞技app not compatible with Fluke CNX testing tools |
雷竞技appFluke a3001 FC iFlex ac current wireless module
Technical indicators | ||
range | 0.5 A - 2500 - A AC | |
The resolution of the | 0.1 A | |
precision | 3% + 5 (5 Hz - 500 Hz) | |
Crest factor (50 Hz / 60 Hz) | 3.0 (1100 A) 2.5 (1400 A) 1.42 (2500 A) C.F. > 2 increased by 2% |
|
W/LCD backlight | 3 1/2 level a | |
Data storage rate/intervals | 1 second (minimum)/can be adjusted by PC or the front panel | |
The battery type | 15 A, 2 AA, NEDA IEC LR6 | |
Battery life | 400 hours | |
memory | Can record up to 65000 readings | |
Radio frequency communication | The 2.4 GHZ ISM band | |
Radio frequency communication range | In the open air, barrier-free | As far as 20 meters |
, gypsum board wall | As far as 6.5 m | |
Wall, concrete, or steel electric shell | As far as 3.5 m | |
Working temperature | - 10 ° C to + 50 ° C | |
Storage temperature | To 40 ° C to + 60 ° C | |
The temperature coefficient of | Increased by 0.1 X (specified accuracy) / ° C (18 ° C or > < 28 ° C) | |
Working humidity | 35 ° C in 90% 40 ° C in 75% 50 ° C in 45% |
|
work | At an altitude of | 2000 m |
Storage temperature | 12000 m | |
Electromagnetic compatibility (EMC) | EN 61326-1:6 | |
Meet safety standards | IEC 61010-1600 - V class / 1000 V class III, IV third edition | |
Security level | The CAT IV III 1000 V 600 V, the CAT | |
certification | CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE | |
Protection (IP) rating | IP42 | |
Pollution levels | 2 | |
Jaw opening | 25.4 cm (10) in the coil | |
Size (high x width x deep) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |
The weight of the | 0.22 kg (8 oz.) | |
Warranty period | Three years, | |
Is雷竞技app not compatible with Fluke CNX testing tools |
Manual + resources: Ti200 a3001 FC iFlex ® suite
- 雷竞技appFluke Connect video is introduced: using TrendIt chart function identification of intermittent fault
- 雷竞技appFluke Connect video introduction: how to save measurements to EquipmentLog history
- 雷竞技appFluke Connect video introduction: how to create equipment through EquipmentLog history function benchmark
- 雷竞技appFluke Connect to perform predictive maintenance
- Us雷竞技appe Fluke Connect the application from a safe distance measurement
- Using ShareLive video sharing real-time measurements and video call function
- How 雷竞技appto use the Fluke Connect application sharing equipment measurements
- How to record the measured value and draw diagrams
- Records automatically by the AutoRecord measurement function measurements
- Th雷竞技apprough the Fluke Connect Connect multiple tools at the same time