China

Ti300 a3001 FC iFlex ® suite

  • 雷竞技appFluke Ti300 a3001 FC iFlex ® Kit
  • 雷竞技appFluke Ti300 a3001 FC iFlex ® Kit
  • 雷竞技appFluke Ti300 a3001 FC iFlex ® Kit
  • 雷竞技appFluke Ti300 a3001 FC iFlex ® Kit
Has been discontinued

The main features

Ti300 thermal imager features below:

  • Proprietary LaserSharp ® autofocus system to ensure accurate shooting focus images
  • - with the help of a fluke IR Fusion technology and AutoBlend ® ™ model precise Fusion visible light image and infrared image
  • Com雷竞技apppatible with Fluke Connect ® wireless network tools
  • Through the wireless image transmission, faster transfer directly to your PC, Apple ® iPhone ® or the ®
  • Rugged 640 x480 resolution capacitive touch screen, can be carried out fast navigation menu
  • Use the IR - PhotoNotes ™ annotation system, additional digital image capture, to show the position or more detailed information on site
  • More advanced display output options, through to the PC or high resolution monitor for video streaming transmission (USB and HDMI) for details
  • By recording and comments, can save the additional detailed information in the image file
  • Optional replaceable lens has greater flexibility in other applications
  • The intelligent battery rechargeable and field replacement, can display power level LED display, can provide excellent flexibility
  • 5 million pixels industrial digital camera performance, can provide high-definition image quality
  • Built-in SmartView ® and SmartView mobile software application analysis and report

3000 FC wireless multimeter to provide:

  • Ac and dc voltage measurement, up to 1000 V
  • Ac and dc current is 0.01 mA resolution
  • Connectivity, resistance, diode testing, capacitance and frequency measurement
  • Minimum/maximum record
  • The CAT III 1000 V, the CAT IV 600 V;IP54

Current through iFlex ™ wireless module, you will be able to cope with tough wire size, or into a narrow space and make it easier to wire access.A3001 FC has:

  • One (1) a true effective value (true - RMS) flexible galvanometer
  • One (1) a iFlex i2500-10 flexible current probe
  • Measured 2500 A alternating current (ac)
  • Can be used as an independent instrument or as part of the system
  • Record function, used to record and save as many as 65000 readings
  • Surge function
  • Magnetic hanging belt
This product has been discontinued or reclassified

Products overview: Ti300 a3001 FC iFlex ® suite

Ti300 a3001 FC iFlex ® is a powerful industrial suite that can help you directly from the rapid, accurate and easy to troubleshoot.Will a3001 FC iFlex wireless communication module connected to your current test points, can see on the 3000 FC DMM 20 meters within the scope of the test results.A3001 FC iFlex module can around compact, narrow space and dimension measurement, can make it easier to wire access.雷竞技appFluke Connect ® application can be saved from the spot testing data and share them with your team to use anytime and anywhere ShareLive ™ video call function to be Shared, and for the first time obtain real-time response and approval.

With LaserSharp ® autofo雷竞技appcus system Fluke products portfolio, Ti300 thermal imager is one of only three thermal imager, ensures reliable shooting focus image for you.Every time if there is no accurate image focus, temperature measurement deviation could be as high as 20 degrees, so it's easy to miss a potential problem.LaserSharp autofocus system can accurately focus on target.In front of the focusing laser is used to calculate the system and the distance between the target.The red laser points on an ongoing flaw detection equipment, and then pull and release the trigger, to get a clear picture of perfect focus.Normal operation or shutdown.Your result is very important.

Product specifications: Ti300 a3001 FC iFlex ® suite

雷竞技appFluke Ti300 infrared thermal imager

Detailed technical indicators
The temperature
Temperature measurement range (10 ° C below not calibration) - 20 ° C to + 650 ° C
(4 ° F to 1202 ° F) +
Temperature measurement precision Plus or minus 2 ° C or 2% (in nominal temperature of 25 ° C, take large number)
Screen emissivity correction Is (according to the number and form)
The screen reflection background temperature compensation There are
The screen transmission correction There are
Imaging performance
Image capture frequency 60 Hz refresh rate
The probe type 240 x 180 pixels focal plane array, uncooled micro thermal detector
Thermal degree (NETD) 30 ° C target temperature, 0.05 ° C (mK) 50 or less
The total pixels 43200
The infrared spectral band 7.5 mu m to 14 microns (long)
Video camera (visible light) Industrial performance, 5 million pixels
Standard infrared lens type
Field of view 17 ° 24 ° x
The spatial resolution (IFOV) 1.75 mRad
The minimum distance 15 cm (about 6 inches)
Optional telephoto infrared lens type
Field of view 12 ° x 9 °
The spatial resolution (IFOV) 0.87 mRad
The minimum distance 45 cm (about 18 inches)
Optional wide-angle infrared lens type
Field of view 34 ° 46 ° x
The spatial resolution (IFOV) 3.49 mRad
The minimum distance 15 cm (about 6 inches)
Focusing mechanism
LaserSharp ® laser af system There are
Advanced manual focus There are
Image display mode
The palette
standard Iron oxide red, blue and red, high contrast, amber, amber, hot metal, gray, gray
Super high Contrast (Ultra Contrast ™) Super iron oxide red, blue and red, high contrast, amber, amber, ultra hot metal, super gray, gray
Level and the span The scope and smooth level automatic adjustment and manual adjustment
Fast automatic switch between manual and automatic mode There are
Manual mode of fast automatic adjustment again There are
Minimum range (manual mode) 2.0 ° C (3.6 ° F)
The minimum range (automatic mode) 3.0 ° C (5.4 ° F)
IR - Fusion ® information
Picture in picture (PIP) There are
Full screen infrared There are
AutoBlend ™ mode There are
Color alarm (alarm temperature) High temperature, low temperature and isothermal (optional) user
Image capture, and data storage
Image capture, view, save mechanism Single hand image capture, view and save functions
A storage medium Micro SD memory card to keep, ram, USB function, connect via USB to computer directly to the download
The file format The radiation (. BMP or jpeg) or total radiation (. Is2)
The radiation survey (. BMP and. JPG) file without using the analysis software
Use SmartView ® software export file format BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF and TIFF
The memory view Thumbnail view navigation and viewing options
The function of the other to save time and improve productivity
Voice note Longest 60 seconds per image recording;Can playback view on thermal imager
IR - PhotoNotes ™ There are
WiFi connection Is connected to the PC, iPhone ®, the ®, creates through WiFi connection to the LAN
Text notes creates There are
Video recording creates Standard and radiation
Streaming video Through the USB to the computer and, through the HDMI to HDMI compatible screen
Com雷竞技apppatible with Fluke Connect Is provided (if any)
Automatic capture (temperature and interval) creates There are
The remote control and operation (applicable to special and advanced application) no
General technical indicators
Working temperature - 10 ° C to + 50 ° C (14 ° F to 122 ° F)
Storage temperature - 20 ° C to + 50 ° C (4 ° F to 122 ° F), no battery
Relative humidity Between 10% and 95% with no condensation
Durable touch screen (capacitive) 8.9 centimeters (3.5 inches) diagonal, horizontal color VGA (640 x 480), LCD backlight
Control and regulation The user can choose temperature unit (° C / ° F)
Language selection
The date/time setting
Emissivity of choice
Reflective background temperature compensation
Transmittance correction
Users can choose the image on the hot and cold spots and center
Extensible/shrinkage measuring box with MIN - AVG - MAX (low - medium - high) three temperature
Color alarm
Users can choose the backlight set the graphics information display preferences
Graphic information display preferences
software SmartView ® and SmartView mobile applications - contains the complete analysis and reporting software
The battery All models are equipped with two intelligent charging lithium ion battery, battery levels through five lattice LED display instructions
Battery life Each battery pack can be continuous use four hours or more (assuming the LCD brightness is 50% and the average intensity of use)
Battery charging time 2.5 hours with
Battery charging communication Double groove ac battery charger (110 VAC to 220 VAC, 50/60 Hz) (attached), or in charge within the thermal imager.Enclosed is the ac power adapter.Optional 12 V car battery adapter.
Alternating current (ac) work Through the attached power supply (110 VAC to 220 VAC, 50/60 Hz) using an alternating current work to accompany the ac power adapter.
Energy saving The user can choose sleep and shutdown mode
Safety standards UL 61010-1:12 CAN/CSA - C22.2 No. 61010-1-12 of IEC 61010-1 version 3 (2010).
Electromagnetic compatibility EN 61326-1:06 IEC 61326-1:05
C Tick IEC/EN 61326-1
US the FCC 47, CFR part 15 B part B class
vibration 0.03 g squared/Hz (GRMS) 3.8, 2.5 g IEC 68-2-6
impact 25 g, IEC 68-2-29
drop Designed to withstand 2 meters (6.5 feet) of drop height (when using the standard lens)
Size (height x width x length) 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
Weight (including battery) 1.04 Kg (2.3 lb)
Shell protection grade IP54 (dustproof sealing protection, all-round waterproof)
Warranty period Two years (standard), can also be extended warranties.
Recommended by the calibration cycle Two years (assuming a normal operation and aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish
1. This functionality is released by the firmware update.Available via the SmartView software users.

雷竞技appFluke 3000 FC series wireless multimeter

* for all specifications: deadline specified for one year after the calibration precision and working temperature of 18 ° C to 28 ° C, relative humidity 0% to 90%.Accuracy specification USES the format for plus or minus (% of [reading] + [the least significant digit]).

Detailed technical indicators
Ac voltage
Range creates/resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Precision squared after4 45 Hz - 500 Hz 1.0% + 3
500 Hz to 1 kHz 2.0% + 3
1. All ac voltage range has been designated as the range of 1% to 100%.
2. The full scale highest do not exceed 500 V the crest factor of 3, when 1000 V linear reduced to crest factor of 1.5.
Compared with three (3) for non sinusoidal waveforms, usually take the crest factor of plus or minus 2% + 2% full scale (reading).
4. Do not over 107 V - Hz.
Dc voltage, connectivity, resistance, diode test and capacitance
function
The mV Range/resolution 600.0 mV / 0.1 mV
precision 0.09% + 2
V Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
precision 0.09% + 2
0.15% + 2
))) Range/resolution Ω Ω / 1, 600
precision < 25 Ω, beeping, buzzer test 250 mu s or more open or short circuit.
Ω Range/resolution 600.0 Ω / 0.1 Ω
6.000 k Ω Ω / 0.001 k
60.00 k Ω Ω / 0.01 k
60.00 k Ω Ω / 0.1 k
600.0 k Ω Ω / 0.001 M
Ω 50.00 M / 0.01 M Ω
precision 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range/resolution 2.000 V / 0.001 V
precision 1% + 2
Including F Range/resolution 1000 nF / 1 nF
10.00 u F / 0.01 u F
100.0 u F / 0.1 u F
9999 mu F1 /1 u F
precision 1.2% + 2
10% of the typical
1. Under the 9999 mu F range measuring 1000 mu F capacitance, the measurement accuracy of 1.2% + 2.
Ac and dc current
function
Ac amps
(45 Hz to 1 kHz)
Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 1.5% + 3
MA DC squared Range creates/ resolution 60.00 mA / 0.01 mA
400.0 mA after / 0.1 mA
precision 0.5% + 3
1. The alternating current range have been designated as the range of 5% to 100%.
2. Enter the load voltage (typical) : 400 mA input 2 mV/mA.
3. According to the 400 mA specified accuracy, overload of 600 mA.
frequency
Range/resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Precision creates 0.1% + 1
1. Specify voltage frequency up to 99.99 kHz, current frequency up to 10 kHz.
The input features
function overload
To protect the
The input impedance
(nominal value)
Common mode rejection ratio (1 k Ω non-equilibrium) Norm inhibition
1100 Vrms > 10 M Ω < 100 pF In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB At 50 Hz or 60 Hz greater than 60 dB
1100 Vrms > 10 M Ω < 100 pF When the dc to 60 Hz, or more than 60 dB At 50 Hz or 60 Hz greater than 60 dB
1100 Vrms > 10 M Ω < 100 pF In dc and frequency of 50 Hz or 60 Hz is greater than 120 dB At 50 Hz or 60 Hz greater than 60 dB
Open circuit voltage Full scale voltage Typical short-circuit current
To 6 M Ω 50 M Ω Typical short-circuit current
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA,
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
MA function
Overload protection 44/100 fuse, A, 1000 V, fuse
overload 600 mA overload for up to 2 minutes, at least 10 minutes to a halt
Minimum/maximum record accuracy
Dc function Specify the precision of the measurement function, duration of > 350 milliseconds changes a total of 12 times.
Communication function Specify the precision of the measurement function, duration of > 900 milliseconds a total of 40 times of change.
General technical indicators
The highest voltage between any terminal and earthing 1000 V dc or ac RMS
Ω A input fuse protection 0.44 A (44/100 A, 440 mA), 1000 V quick f雷竞技appuse, Fluke specified components only
Display (LCD) Update rate 4 / SEC.
The volt, ampere, ohm 6000 times
frequency 10000 times
capacitance 1000 times
The battery type Three AA alkaline batteries, NEDA IEC LR6 15 a
Battery life At least 250 hours
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
work The temperature - 10 ° C to 50 ° C
Storage temperature To 40 ° to 60 ° C C
The temperature coefficient of The set accuracy 0.1 x () / ° C (18 ° C or > < 28 ° C)
Relative humidity From 0% to 90% (0 ° C and 35 ° C)
From 0% to 75% (35 ° C to 40 ° C)
From 0% to 45% (40 ° C to 50 ° C)
work At an altitude of 2000 m
Storage temperature 12000 m
Electromagnetic compatibility
EMI and RFI, EMC (EMC) and RF
EN 61326-1:6, EN 61326-2 - "06
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
The FCC part 15 C in section 15.207, 15.209, 15.249, all applicable requirements
FCCID: FCC: T68 - FDMMBLE IC: 6627 a - FDMMBLE
Meet safety standards The ANSI/ISA 61010-1 / (82.02.01) : 3rd edition
CAN/CSA C22.2 No. 61010-1-12:3rd edition
UL 61010-1:3
IEC/EN61010-1:10
certification CSA, the FCC, CE
Protection (IP) rating IP54
Pollution levels 2
Size (height x width x length) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
The weight of the 340 g (12 oz)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

雷竞技appFluke a3001 FC iFlex ac current wireless module

Technical indicators
range 0.5 A - 2500 - A AC
The resolution of the 0.1 A
precision 3% plus or minus five (5 Hz - 500 Hz)
Crest factor (50 Hz / 60 Hz) 3.0 (1100 A)
2.5 (1400 A)
1.42 (2500 A)
C.F. > 2 increased by 2%
W/LCD backlight 3 1/2 level a
Data storage rate/intervals 1 second (minimum)/can be adjusted by PC or the front panel
The battery type 15 A, 2 AA, NEDA IEC LR6
Battery life 400 hours
memory Can record up to 65000 readings
Radio frequency communication The 2.4 GHZ ISM band
Radio frequency communication range In the open air, barrier-free As far as 20 meters
, gypsum board wall As far as 6.5 m
Wall, concrete, or steel electric shell As far as 3.5 m
Working temperature - 10 ° C to + 50 ° C
Storage temperature To 40 ° C to + 60 ° C
The temperature coefficient of Increased by 0.1 x (specified accuracy) / ° C (18 ° C or > < 28 ° C)
Working humidity 35 ° C in 90%
40 ° C in 75%
50 ° C in 45%
work At an altitude of 2000 m
Storage temperature 12000 m
Electromagnetic compatibility (EMC) EN 61326-1:6
Meet safety standards IEC 61010-1600 - V class / 1000 V class III, IV third edition
Security level The CAT IV III 1000 V 600 V, the CAT
certification CSA, CE, FCC, T68 - FBLE IC: 6627 a - FBLE
Protection (IP) rating IP42
Pollution levels 2
Jaw opening 25.4 cm (10) in the coil
Size (high x width x deep) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
The weight of the 0.22 kg (8 oz.)
Warranty period Three years,
Is雷竞技app not compatible with Fluke CNX testing tools

Model: Ti300 a3001 FC iFlex ® suite

FLK - Ti300 / FCA Kit
雷竞技appFluke Ti300 a3001 FC iFlex ® Kit

Includes:

Ti300 Infrared Camera

  • The AC power supply and 'pack charger (o mains adapters)
  • Two, rugged lithium ion smart 'packs
  • Micro SD memory card
  • The USB cable
  • HDMI video cable
  • SmartView ® software available via free download
  • Rugged, hard to their case
  • Soft transport bag
  • Adjustable hand strap
  • Giant registration card
  • International adapter set (9 Hz only)

3000 FC Series Wireless Multimeter

  • 雷竞技appFluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)
  • One (1) a3001 FC Module with two (2) AA batteries (installed)
  • One (1) iFlex 10 "" coil
  • One (1) all/strap
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • 3 - compartment C3003 soft case
  • Information pack