雷竞技appFluke TiX1000 infrared thermal imager
The main features
- Use 32 times digital zoom, taken from a safe distance from testing can still be taken photo.
- For the application of your choice and convenient image transmission protocol: thermal imager data port, image transmission, SD card, USB 2.0, video output DVI - D (HDMI).GigE vision and RS232 in 2015.SmartView ® software: SD card.USB 2.0, GigE Vision and RS232 in 2015.
- Using 8 MP camera visible light, and obtain the norm of IR image Fusion ®.
- There are multiple view options available at the scene of the viewfinder view images, outdoor use.
- User-defined Settings button can realize personalized, for quick access to commonly used functions.
- The MATLAB ® and LabVIEW ®Compatibility allows users to integrate the thermal imager data to support the research and development, infrared video and infrared image analysis.
- Can be set to a high frame frequency mode to 240 Hz frame rate for advanced application (additional options) handheld thermal imager.
What is the high frame frequency mode?
Sudden rapid temperature change may be a key part of an analysis.Experts series thermal imager (TiX1000, TiX660 and TiX640) provides an optional mode of high frame frequency (when buying a thermal imager.This function is only found in cooled infrared thermal imager.Using the infrared thermal image instrument series, the user can record and analyze many frames per second data, in order to better understand the sudden temperature changes.
Thermal imager add optional accessories can provide the following frame rate:
- Options for 40 x 480 (60 FPS)
- Option 2:38 4 x 288 FPS (120)
- Option 3:10 24 x 96 FPS (240)
*In the provider's wireless service area.
Produc雷竞技appts overview: Fluke TiX1000 infrared thermal imager
Check the fluke expert infrared thermal imager to generate excellent image.Watch the video
See what you see.
Easy to check the details from a distance. |
|
Embryo incubation monitoring (blue represents stillbirth) at low temperature. |
|
Eight kinds of optional lenses and realize the multifunction. |
|
What is the precise displacement imaging technology?
Under normal circumstances, the infrared image pixels are not between detector captures the blank area, namely the sensitive space between the sensing element, and fluke imaging precision displacement through the instantaneous capture much of the heat will be 4 times sensing element extension, empty area 100% coverage, to improve the image resolution by 4 times.
Eversharp multipoint focus imaging system is what?
Only the fluke Eversharp multipoint focus imaging system can capture from different focal length, many images were combined into a sharp image, let your heat maps without xu jiao, focus every temperature data is accurate.
The high quality image into a super clear image.Choose for your application for optional lens.Understand the related product details, please see the right, or, if you want to get all the list, please see the bottom of the models and accessories tag.
*With precise displacement imaging technology to capture and can use SmartView ® software (only TiX1000) view high-definition images.When shooting cannot see high-definition images.
Produc雷竞技appt specifications: Fluke TiX1000 infrared thermal imager
Image quality | |
Spatial resolution IFOV () | 0.6 mRad |
Image resolution (pixel) | 1024 x 768 (786432 pixels) |
2048 x 1536 (3145728 pixels, open the precision displacement imaging) | |
Under the frame rate (maximum image resolution) | 30 and 9 Hz |
Super resolution and dynamic super resolution (resolution enhancement) | Yes, four times the MicroScan technology in infrared measuring pixels |
provide | Options for 40 x 480 (60 FPS) Option 2:38 4 x 288 FPS (120) Option 3:10 24 x 96 FPS (240) |
Field of view (FOV), equipped with standard 30 mm lens | 32.4 ° x 24.7 ° |
Thermal degree (NETD) | 30 ° C target temperature, 0.05 ° C (mK) 50 or less |
Spectral range | 7.5 (including including m to 14 m |
A wireless connection | |
Com雷竞技apppatible with Fluke Connect ® | There is no |
IR - Fusion ® infrared optical Fusion technology | |
AutoBlend ™ mode | There are |
The view mode | Picture in picture, joining together in a row, color alarm (above and below the user defined temperature) |
Af system | |
LaserSharp ® laser automatic focus | There are |
autofocus | There are |
Manual focus | Is, get a more compact view through his finger |
EverSharp focus more recording | , much focus recording can capture from different focal length of the image, and will be merged into an image, many images with high quality and good image quality and display various objects |
Temperature measurement | |
range | To 40 ° C to + 1200 ° C (to 40 ° F to 2192 ° F), high temperature options - may be required when ordering: up to 2000 ° C (3632 ° F) |
precision | + / - 1.5 ° C or plus or minus 1.5% |
Correction function | LDC ™ - based on the distance of the laser rangefinder correction, emissivity (manual or material list) |
Transmittance, | |
Data storage and image capture | |
Image/video store | SDHC memory card |
Image/data transmission interface | Thermal imager data port support: image transmission: SD card, USB 2.0, video output DVI - D (HDMI).GigE Vision and RS232 listed in 2015 |
SmartView ® software: SD card.USB 2.0, GigE Vision and RS232 listed in 2015 | |
General technical indicators | |
The laser pointer | Is that a laser level: 2 |
Laser range finder | Accuracy: + / - 1.5 mm Range: 70 m (230 ft) Wave length: 635 nm (red) Laser level: 2 |
display | Large 5.6 "TFT color display, 1280 x 800 pixel resolution, suitable for operation under the sun |
Geographic information positioning | Built-in GPS used in geographic location |
Visible digital camera | The highest resolution of 8 million pixels, can take images and video recording |
Digital zoom | Up to 32 x digital zoom |
Text notes | There are |
Voice note | There are |
audio | Integrated microphone and speaker for voice note |
A/D conversion | 16 |
The power supply | External: 12 VDC to 24 VDC Battery: standard lithium ion camera battery |
Equipped with a replaceable intelligent battery level indicator LED | Two pieces of |
Working temperature | 25 ° C to + 55 ° C (13 ° F to 131 ° F) |
Storage temperature | To 40 ° C to + 70 ° C (to 40 ° F to 158 ° F) |
humidity | Relative humidity of 10% to 95%, with no condensation |
impact | Run: 25 g, IEC 68-2-29 |
vibration | Run: 2 g, IEC 68-2-6 |
Protection grade | IP54 |
Human body engineering design | Camcorders, with his hand |
The viewfinder | Can tilt the LCoS viewfinder color display, 800 x 600 pixel resolution |
Standard size (including 1.0/30 mm lens | 210 mm * 125 mm * 155 mm (8.25 x 4.9 x 6.1 in) |
Weight (including 1.0/30 mm standard lens) | 1.95 kg (4.3 lb) |
Measurement functions (select) | Multiple points and interest (ROI), |
Automatic function (option) | Focus, images, level, range, NUC, camera recognition, image optimization, alarm sequence |
SmartView ® software | There are |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish. |
Warranty period | 2 years |
Mode雷竞技appl: Fluke TiX1000 infrared thermal imager
- Two pieces of rechargeable batteries
- The battery charger and current adapter
- The AC adapter (communication)
- SD card reader
- Used for fluke Connect ™ FC SD card (not on all countries to provide)
- The lens cap
- Wrist strap and neck band
- Carrying case
- Warranty card and safety instructions
- Calibration certificate
- Two pieces of rechargeable batteries
- The battery charger and current adapter
- The AC adapter (communication)
- SD card reader
- Used for fluke Connect ™ FC SD card (not on all countries to provide)
- The lens cap
- Wrist strap and neck band
- Carrying case
- Warranty card and safety instructions
- Calibration certificate