雷竞技appFluke TiX501 thermal imager

  • The Capture high quality thermal images with precision using 640 x480 resolution
  • The 240 - degree rotating screen top service it easy to capture images in awkward or hard - to - reach areas
  • Make preventive maintenance decisions quickly with more thermal sensativity
  • For infrared inspections in manufacturing, is suing substations or conducting an energy audit on a ltd. building
  • Make preventive maintenance decisions quickly with more thermal sensativity

The main features

  • With the aid of up to 640 x 480 resolution images, view the images in the little details and faster to find anomalies.
  • Shooting focal near and far focus images.Intelligent interchangeable lens does not need to be calibrated, to provide you with check in almost any environment required versatility and image quality.
  • Easy to find the small temperature difference, have the advanced heat sensitive.

Produc雷竞技appts overview: Fluke TiX501 thermal imager

Capture complete reliability testing, industrial maintenance decision-making, execution building diagnostic testing and troubleshooting high-definition heat as needed.Use the clear screen can rotate 240 degrees, in not convenient or hard-to-reach areas effortlessly.Even in the top of the head image, and difficult to close to the target above, below and around the image, the ergonomic design will also let you can flexibly thermal imager is fixed in a comfortable position.Use of the analysis and reporting capabilities for software asset tag, streaming transmission infrared data, trend analysis and remote thermal imager.

Produc雷竞技appt specifications: Fluke TiX501 thermal imager

Key features
Infrared resolution 640 x 480 (307200 pixels)
Super pixel technology no
IFOV (spatial resolution) standard lens 0.93 mRad, D: S 1065:1
Viewing Angle 34 ° H x 24 ° V
The minimum focus distance 15 cm
MultiSharp focus more no
LaserSharp laser automatic focus Have, to be consistent focus image.Each style.Singles.Times.
Laser ranging function There is, to calculate the distance to the target to obtain a precise focus images, and displayed on the screen this distance
Advanced manual focus is
A wireless connection There, to connect to PC, iPhone ® and the ® (iOS 4 s and updated version), and the Android ™ and updated version 4.3, WiFi to connect to a LAN (if any)
Com雷竞技apppatible with Fluke Connect APP applications *, Connect the thermal imager 雷竞技appto smart phones, will take images automatically and upload images to Fluke Connect application for preserving and sharing
雷竞技appFluke Connect Assets * * in the future, the image will automatically assigned to the assets, in a position easily compare measurement type, and create a report through the cloud based system.
雷竞技appFluke Connect cloud upload immediately *, Connect the thermal imager to WiFi 雷竞技appnetwork, the architecture of a recording images automatically and upload images to Fluke Connect system for your view on the smart phone or PC
雷竞技appFluke Connect server upload immediately Is * *
IR - Fusion of infrared and visible light Fusion technology Yes, add the visual details for infrared images
Durable touch screen 5.7 inches (14.4 centimeters) lateral 640 x 480 LCD
Human body engineering design Can rotate 240 ° (joint)
Thermal sensitivity (NETD) * * 30 ° C target temperature, 0.075 ° C (75 mK) or less
Level and the span Automatic and manual zoom smoothly
Touch screen level/span is adjustable Is.Just touch the screen to easily and quickly set up the scope and level
Fast automatic switch between manual and automatic mode is
Manual mode of fast automatic adjustment again is
Minimum range (manual mode) 2.0 ° c.
The minimum range (automatic mode) 3.0 ° c.
With a built-in digital camera (visible light) 5 mp
Frame frequency 60 Hz or 9 Hz model
Laser designation is
Leds (light torch) is
Digital zoom 2 times
Data storage and image capture
Selection of storage Portable 4 GB micro SD memory card, 4 GB built-in flash memory, can be saved to the U disk, can upload for permanent storage
Image capture, view, save mechanism There is, on the thermal imager for editing and image analysis
The image file format BMP, jpeg, is2, is3, AVI
The memory view Thumbnails and full screen view
software Acce雷竞技appssible Fluke Connect system comprehensive analysis and reporting software
Analysis on the PC and store the radiation data is
Use雷竞技app Fluke Connect software export file format Bitmap (BMP), GIF, JPEG, PNG, TIFF
Voice note Longest 60 seconds per image recording;Can playback view on thermal imager;Optional bluetooth headset but not required
IR - PhotoNotes Is to 2 image
Text notes Is.Including standard shortcuts and user programmable options
Video recording and format standard
The remote control operation Thr雷竞技appough the Fluke Connect remote display
Automatic capture (temperature and interval) no
The MATLAB ® and LabVIEW ® toolbox The thermal imaging data, infrared video and image are integrated into the software to support the research and analysis
The battery
Replacement, rechargeable batteries (can live) Two smart li-ion battery pack, through five lattice LED display to indicate that the power level
Battery life 2-3 hours/battery (according to the condition of specific set up and use, the actual working hours may vary)
Battery charging time 2.5 hours with
Battery charging system Double tank battery charger or within the thermal imager.Optional 12 V car battery adapter
Alternating current (ac) work Through the attached power supply (100 VAC to 240 VAC, 50/60 Hz) using an alternating current work
Energy saving The user can choose sleep and shutdown mode
Temperature measurement
Temperature measurement range (10 ° C below not calibration) - 20 ° C to + 650 ° C
(4 ° F to 1202 ° F) +
precision Plus or minus 2 ° C or 2% (25 ° C, take larger value)
Screen emissivity correction Is (number) and form
The screen background temperature compensation can be adjusted is
The instrument can be carried out on the transmittance correction is
Line temperature figure no
The palette
The standard palette 8: iron oxide red, blue and red, high contrast, amber, amber, hot metal, gray, gray
Ultra Contrast Contrast color palette 8: super iron oxide red, blue and red, high contrast, amber, amber, ultra hot metal, super gray, gray
Smart camera
25 MAC2 macro lens: 25 microns is
2 times the telephoto lens: TELE 2 is
Four times the telephoto lens: TELE4 is
Wide-angle lens: 2 WIDE is
General technical indicators
Color alarm (alarm temperature) High temperature, low temperature and isothermal (range)
Infrared wavelengths 7.5 mu m to 14 microns (long)
Working temperature - 10 ° C to + 50 ° C
Storage temperature - 20 ° C to + 50 ° C does not contain batteries
Relative humidity Between 10% and 95% with no condensation
Central point temperature measurement is
Point temperature Hot and cold spots mark, enabled
User definable point mark Two user definable point mark
User defined metering box One can increase/decrease metering box, with MIN - AVG - MAX (low - medium - high) three temperature display
Hard portable box Strong and durable, IP67 rating, airtight hard shell, with custom bubble plug-in
security IEC 61010-1: overvoltage category II, pollution level 2.
Electromagnetic compatibility IEC 61326-1: basic electromagnetic environment.CISPR 11: group 1, A class
Australia RCM IEC 61326-1
US the FCC 47, CFR part 15 B section
Vibration resistance G2/0.03 Hz (3.8 g), 2.5 g of IEC 60068-2-6
impact 25 g, IEC 68-2-29
fall Designed to be bear dropped from 1 meter (3.3 feet) high (when using the standard lens)
Size (height x width x length) 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in)
Weight (including battery) 1.54 kg (3.4 lb)
Shell protection grade IEC 60529: IP54 (dustproof sealing protection, all-round waterproof)
Warranty period Two years (standard), can prolong the warranty
Recommended by the calibration cycle Two years (assuming a normal operation and aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, polish, Portuguese, Russian, simplified Chinese, Spanish, Swedish, traditional Chinese and Turkish
Conform to the RoHS standard is

Plea雷竞技appse note: Fluke Connect analysis and reporting software in all countries/regions are provided, and the Fluke Connect is not the case.Please consult your authorized fluke dealer

* * s雷竞技appaid Fluke Connect ™ features coming soon.About the software and firmware updates, please check the fluke website.

Mode雷竞技appl: Fluke TiX501 thermal imager

FLK - TiX501 60 HZ

雷竞技appFluke TiX501 thermal imager 60 Hz

Include:

  • Equipped with standard infrared thermal imager
  • The ac power and battery charger (including universal power adapter)
  • Two durable intelligent rechargeable lithium-ion battery pack
  • USB cable
  • HDMI video line
  • Bluetooth headset (if any)
  • Solid hard carry bag
  • Adjustable neck and wrist strap
  • Free 雷竞技appdownload Fluke Connect ® SmartView ® desktop software and user manual
FLK - TiX501 9 HZ

雷竞技appFluke TiX501 thermal imager 9 Hz

Include:

  • Equipped with standard infrared thermal imager
  • The ac power and battery charger (including universal power adapter)
  • Two durable intelligent rechargeable lithium-ion battery pack
  • USB cable
  • HDMI video line
  • Bluetooth headset (if any)
  • Solid hard carry bag
  • Adjustable neck and wrist strap
  • Free 雷竞技appdownload Fluke Connect ® SmartView ® desktop software and user manual