雷竞技appFluke 190 Series III ScopeMeter ® Test Tool

  • 雷竞技appFluke 190-504 Series III Portable Oscilloscope
  • 雷竞技appFluke 190-504 Series III Handheld Oscilloscope
  • 1000 V / 600 V rated IV CAT CAT III portable oscilloscope
  • Four channel portable handheld oscilloscope

The main features

  • Applies to 1000 V / 600 V IV CAT CAT III industrial environment
  • Automatic capture, display and analysis of complex waveform
  • Bright large color display, facilitate the scene view
  • USB download way and 雷竞技appwi-fi, to use FlukeView ® software to analyze data
  • Up to four separate floating isolated input, up to 1000 V

Produc雷竞技appts overview: Fluke 190 Series III ScopeMeter ® Test Tool

High-performance portable oscilloscope, specially designed for harsh conditions

雷竞技appFluke 190 Series III ScopeMeter ® Test Tool designed specifically for use in different locations, can handle any troubleshooting work anytime and anywhere.These 1000 V / 600 V grade IV CAT CAT III test tool to rugged portability combined with high-performance desktop oscilloscope, help you to easily cope with the installation, commissioning and maintenance of industrial machinery, automation/process control devices and power conversion devices (from dc to 500 MHz) challenge.

Choose double channels or four types, and the bandwidth selection range.Fast sampling rate is as high as 5.0 GS/s, a resolution of 200 ps, the depth of each channel memory can store 10000 samples, which can capture and display waveform high-precision details, noise and other distractions.Available in three phase or three axis control system on timing or amplitude measurement, related or measured on the comparison and contrast in multiple test points.TrendPlot ™ paperless recorder, ScopeRecord ™ mode, Connect - and - View ™ trigger functions as well as the unique 100 screen playback function can help you diagnose the problem quickly, to a greater extent to reduce maintenance costs and downtime.These features make the oscilloscope is easy to use, especially in the diagnosis of the most difficult problems, such as complex waveform, induction noise, intermittent events and fluctuations or drift.

  • Up to four separate floating isolated input, up to 1000 V
  • Top 5 GS/s real-time sampling rate (depending on the use of models and channel)
  • Depth of memory, every time capture wave feature line, can store 10000 points (oscilloscope mode)
  • Is suitable for the industrial environment of 1000 V / 600 V IV safety CAT CAT III instruments
  • The adoption of BP291 battery, battery life for seven hours
  • Bright large color display, in almost any environment is easy to see
  • Easy to store and view the history data, and transmits the PC through USB or Wifi
  • Easy open and close the battery cover, can rapidly change the battery
  • Dustproof and waterproof level for IP51
  • Connect - and - View the trigger function, in View of fast, slow, and even complex signal can intelligently trigger automatically
  • Spectrum using FFT analysis
  • 100 automatic screen capture and replay
  • ScopeRecord mode can provide 30000 points for each input channel, for low frequency signal analysis
  • TrendPlot paperless recorder mode, has a deep memory, in order to realize the automatic measurement for a long time
  • 2 channel model contains 5000 count multimeter (DMM)

Security to mV kV voltage measurement

Independent isolated input enables you to mix with different ground reference circuit measurement, which reduces the risk of accidental short circuit.Traditional desktop oscilloscope probe has not been equipped with a special difference and isolation transformer, only the grounding end as measuring reference end of line power supply.Fluke 190 iii oscillographic table test suite designed for cover from the mV to kV designed a variety of applications, so you can deal with from microelectronics to heavy high voltage electrical application of any problems.Iii 60 190 MHZ and 100 MHZ configuration includes VPS421 for high voltage applications, 100:1 probe, and 200 MHZ and 500 MHZ configuration includes suitable for microelectronics and high voltage application VPS410 - II 10:1 probe.

Suitable for harsh environment protection class IP - 51

Oscillographic table test suit durable and vibration control, is suitable for use in dirty and dangerous environment.Equipped with a sealed enclosure, dustproof, droplets, moisture proof, and against air pollution.Each use of oscillographic table test, you can be at ease use, it can reliably solve any problem for you.

USB and wi-fi connection

雷竞技appFluke 190 Series III provides two and measurement to realize electrical isolation between the input circuit of USB port, this enables you to quickly and easily to transmit the data to PC, after the archive and OEM, colleagues and support staff share the waveform, or set the waveform, screen shots and instrument stored in the USB storage devices, for future use.Through USB transmission easily save the file, via USB or optional wi-fi network directly connected to the computer.These files can be 雷竞技appused for further data processing, or in the FlukeView - 2 software is used to study in more detail waveform.

Connect - and - View the trigger function

Connect - and - View the trigger function can provide real-time, stable display, do not need to adjust the Settings.If you ever use other oscilloscope, you will understand how tricky trigger.If the setting is not correct, the results may not be stable or not correct.Connect - and - by identifying the View function to automatically set the right trigger signal mode.Without having to touch the button, you can stable, reliable, repeatedly shows that almost all of the signals, including the motor drive and control signals.When you fast, continuously measuring a series of test points, this feature is especially fast and convenient.

Connect and View function can capture the most complex signal, without the need for additional Settings
Built-in multimeter can be convenient and precise measurement

The built-in digital multimeter

Using dual channel 190 type iii on the built-in 5000 words digital multimeter, waveform analysis allows you to easily convert multimeter measurement precision.Measurement features include Vdc, Vac, Vac + dc, resistance, on-off and diode testing.Will the right shunt, probes or adapter with a variety of scale factor, the combination of measured current and temperature.

Used to record high resolution waveform ScopeRecord ™ mode

ScopeRecord memory for each channel can store up to 30000 or more data points, and can be captured 8 ns rapid intermittent events as short and short pulse wave interference.(two set of multi-channel records can be stored in the memory, for later analysis.)

  • Record events such as start UPS, power supply or motor cycle
  • With the aid of the "stop" when triggered mode, ScopeMeter Test Tool can automatically identify power failure and waveform data storage before failure
Using ScopeRecord ™ mode to capture the details of the high resolution waveform for a long time
Map multiple trend, thus trap events of intermittent signal, the signal drift or fluctuation problem

TrendPlot paperless recorder, record for 11 days, can help you find the intermittent failures

The hardest thing to find failure is the occasional failure.These events may be intermittently by improper connection, dust, dirt, corrosion, wire break or damaged joint.Lines, plunged, surge and interruptions, or motor start and stop could lead to a stop.When that happens, 雷竞技appyou may not be near, but the Fluke 190 Series III ScopeMeter Test Tool will help you to monitor at any time.

  • Show changes over time of the minimum and maximum peak and average
  • Show any combination of up to four readings, including all the input voltage, current, temperature, frequency and phase, all these are marked with the time and date, in order to find out the fault

雷竞技appFlukeView2 software is used to record, archive, and analysis

Understanding is雷竞技app equipped with Windows version FlukeView 2 ScopeMeter ScopeMeter software Test Tool for details.

  • Record of waveform, screenshots and data transmission to the PC, to print or send data import to the report
  • Add text to the ScopeMeter Test Tool setting - call setup for operators to provide relevant guidance
  • Archive - create waveform library, for easy reference or comparing waveform
  • Export data analysis, use the cursor function or to another analysis program
雷竞技appFlukeView - 2 ScopeMeter software

Produc雷竞技appt specifications: Fluke 190 Series III ScopeMeter ® Test Tool

Oscilloscope mode
190-062. 190-102. 190-202. 190-502. 190-104. 190-204. 190-504.
Vertical deflection
The channel number 2 2 2 2 4 4 4
bandwidth 60 MHz 100 MHz 200 MHz 500 MHz 100 MHz 200 MHz 500 MHz
Rise time 5.8 ns 3.5 ns 1.7 ns 0.7 ns 3.5 ns 1.7 ns 0.7 ns
Oscilloscope input number Two input channels and external trigger 4 input channel
Channel architecture All input between each other and with the ground insulation completely.Input can be any combination of activation.
The input coupling Ac or dc with ground level instructions
The input sensitivity Using 10:1 probe, 20-1000 - V/mV
USES 100:1 probe, the 200-10 kV/mV
Dc (1:1) 2-100 - V/mV
Bandwidth limiter 20 MHz and 10 kHz
polarity Normal, reverse, variable
The input voltage 1000 V / 600 V IV CAT CAT III safe level, more detailed information, please see the general technical indicators
Vertical resolution eight
Precision (4 s - 10 mu s/g) 5-100 - V/mV/frames, plus or minus 1.5% (+ 6)
2 / mV, plus or minus 1.5% (+ 10 counts)
The input impedance 1 M Ω (+ 1%) / / 15 pF (+ / - 2.25 pF)
Level display
The largest real-time sampling rate (sample) at the same time 625 Ms/s
Each channel ()
1.25 GS/s (each channel) 2.5 GS/s (each channel) 5 GS/s (single channel) or
2.5 GS/s (dual channel)
1.25 GS/s (each channel) 2.5 GS/s (ch 2)
1.25 GS/s (ch)
5 GS/s (single channel) or 2.5 GS/s (dual channel) or 1.25 GS/s (four channels)
Record length Each channel up to 10000 samples
Time base scope 10 ns/div
To 4 s/div
5 ns/div
To 4 s/div
2 ns/div
To 4 s/div
1 ns/div
To 4 s/div
5 ns/div
To 4 s/div
2 ns/div
To 4 s/div
1 ns/div
To 4 s/div
For the 1-2-4 time base order
Using ScopeRecord ™ scroll mode (see the "recorder model") get slower "/" Settings
Record the length of the largest In the oscilloscope mode, each channel sampling number is 10000;
In ScopeRecord ™ scroll mode (see the "recorder model"), each channel can be recorded 30000 points
Timing accuracy The plus or minus 0.01% (reading + 1 px)
Capture a short pulse wave interference 8 ns (including 10 to 2 min/s/frames)
Display and collect
display 133 mm x 90 mm (5.3 in x 3.5 in) full color high brightness LCD
Display mode Channels can be any combination, average mode on/off;The replay mode.
Visual screen width Oscilloscope mode with 12 level
Continuous digital model When closed, the short, medium, and long, infinite and envelopment model
Waveform mathematical application In the two input channels (A and B, C and D) executed on A (190 - xx2) or two (190 - x04) mathematics: addition, subtraction, multiplication;X-y model;FFT analysis of the spectrum
Acquisition mode Normal, average, automatic, single sampling, ScopeRecord ™ scroll, short pulse interference capture, "pass/fail" automatic test waveform comparison;The replay
Trigger and delay
Signal source Input A, B or external input (via the instrument input) Input A, B, C or D
model Automatic, edge, pulse width, N - Cycle, external (190 - xx2)
Connect - and - View ™ Advanced automatic trigger can identify the mode, automatically set and continuously adjust the trigger, and amplitude.Automatic display complex and dynamic signal (e.g., motor drive and control signal) the stability of the waveform.Also can choose according to individual be fond of closure.
Trigger pulse width (channels) on A By the time limit of the pulse width
Can t = t, in < t >, indicates t triggered when, with 0.01 t among them or the minimum step to select 50 ns
Time delay A trigger before the full screen view, or as many as 100 after the trigger delay screen (= 1200)
Dual slope trigger A similar trigger the rising and falling
N - cycle triggered In the presence of triggers the NTH trigger;N set in the range of 2-99
Automatically capture 100 screens
In the oscilloscope mode, the instrument always can store the last 100 - without specific user Settings screen.When discovery is unusual, can be repeatedly "replay" button to view the screen sequence of all events.Instrument can be set up for short-term trigger or intermittent abnormal trigger pulse interference, and will be in "care" mode, and capturing 100 specified event.
The replay Manual or continuous playback.In the form of a "real time" animation or under manual control displays the 100 screen capture.Each screen has a date and time stamp.
Replay storage The screen may be retained within the two groups (each group of 100), for later calls and analysis.Additional screen through the USB host port group directly stored in the external flash drive.
FFT spectrum analysis
Using fast Fourier transform of display oscilloscope waveform frequency
The window function Automatic, hamming, hanning or no
The automatic window function In digital way for collecting waveform sampling again, with the FFT is reasonable to get the best frequency resolution.
Vertical scale Linear/log (in volts or amps)
The frequency axis Frequency range automatically set as the function of the base when the oscilloscope
Waveform comparison and pass/fail test
Waveform comparison To provide the reference waveform storage and display, with his new acquisition waveform visual comparison.Reference waveform from the acquisition of waveform, and can be modified in the oscilloscope.
Pass/fail test In the waveform comparison mode, the oscilloscope can be set to only matches (" through "), or does not match (" failure ") acquisition of the waveform is stored in the replay memory chips, for further analysis.
Oscilloscope automatic measurement
V dc, ac + V ac RMS, V dc, V (maximum peak), V (minimum peak), V (peak value), A ac, A dc, ac + dc, frequency (Hz), A rise time (using the cursor), decrease time (using the cursor), power factor (PF) reactive, wattage, VA, VA, phase (2) between the input (kathi Jones from A&B or C&D), pulse width (positive/negative), the duty ratio (positive/negative), ° C temperature, temperature ° F () does not apply to Japan, dBV, dBm (Ω corresponding Ω 50 and 600), the VPWM ac and VPWM (ac + dc) (used to measure the pulse width modulation motor drives and converter), V/Hz ratio;
High power and motor drive function V/Hz ratio, power factor (PF), wattage, VA, reactive VA, V - - PWM PWM (ac) and V (ac + dc) (used to measure the pulse width modulation motor drives and converter)
The cursor measurement
Signal source In arbitrary input waveform or mathematical synthesis waveform (not including x-y mode)
Double horizontal line Cursor 1 and 2 cursor in the voltage, the voltage between the cursor
Double vertical line Time, between the cursor between the cursor 1 / T (in Hz), mark the voltage between the rise time of a tag, the marked decline in time;The cursor Vrms, between the cursor between the wattage.
A single vertical line The cursor location of the minimum, maximum voltage, and the average voltage FFT frequency and root mean square of single frequency component in the amount of value
Advanced features MA * (s) between current changes with time, the cursor;V * (s) between voltage change with time, the cursor;W * s (between energy consumption and the cursor)
The zoom Zoom range is from the overview of amplification to sample level, suitable for any record length.
Meter mode
190-062. 190-102. 190-202. 190-502. 190-104. 190-204. 190-504.
The instrument input With oscilloscope by 4 mm banana plug input, input and grounding is completely isolated Through the BNC input oscilloscope
Reading the number By DMM input each read a multimeter A maximum of four oscilloscope automatic measurement at the same time
The highest resolution 5000 count Plus or minus 999 counts
(counting frequency: 9999)
The input impedance 1 M Ω (+ 1%) / / 14 pF (+ / - 1.5 pF) 1 M Ω (+ 1%) / / 15 pF (+ / - 2.25 pF)
Advanced instrument function Automatic/manual range, relative measurement benchmark (zero), TrendPlot ™ records
When the temperature range for 18 ° C - 28 ° C, the specified accuracy effectively.The temperature低于 18 °C 或高于 28 °C 时,温度每变化 1 °C,精度变化指定精度的 10%
voltage
V dc accuracy Counting 0.5% plus or minus (+ 6) Counting 1.5% plus or minus (+ 6)
V ac true RMS accuracy
15 Hz to 60 Hz Plus or minus 1% (+ 10 counts) Plus or minus 1.5% (+ 10 counts)
60 Hz to 1 kHz + + 15 counts (2.5%) -
60 Hz and 20 kHz - + + 15 counts (2.5%)
True RMS ac + V dc accuracy
15 Hz to 60 Hz Plus or minus 1% (+ 10 counts) Plus or minus 1.5% (+ 10 counts)
60 Hz to 1 kHz + + 15 counts (2.5%) -
60 Hz and 20 kHz - + + 15 counts (2.5%)
Voltage meter range 500 mV, 5 V, 50 V, 500 V, 1100 V
resistance
range 500 Ω Ω, 50 k, 5 k Ω Ω, 500 k Ω, 5 M and 30 M Ω -
precision Counting 0.6% plus or minus (+ 6) -
Other instrument functions
On and off sex < 50 Ω (plus or minus 30 Ω) when the buzzer -
Diode test The highest 2.8 V -
Current (A) A dc, ac, A A ac + dc, using an optional current clamp or shunt ratio factor: 0.1 mV/A, 1 mV/A - 100 mV/V/A and 400 A
The temperature With optional accessories.The scaling factor 1 mv / ° C or 1 mv / ° F
Recorder mode
190-062. 190-102. 190-202. 190-502. 190-104. 190-204. 190-504.
ScopeRecord ™ scroll mode
Double input or input waveform storage mode, the use of deep memory
Signal source and display Type A, type B, the double input
All channel sampling at the same time
Any combination of input, college as many as four channels.
All channel sampling at the same time
The depth of the storage The 30000 data points, each channel can be stored separately for minimum/maximum information
Minimum/maximum To measure the size of the sample under the high sampling rate to create minimum/maximum, to ensure that capture and display the short-time pulse interference.
Recording mode A single scan, continuous rolling;Triggered when open (through the external input);Trigger stops (through external input) A single scan, continuous rolling;Triggered when open (through any channel);Trigger stops (through any channel)
Triggered when to stop ScopeRecord mode can pass any input channel (190 - series XX2 is through external input)
Triggered by a single event or by repeated interrupt trigger signal to stop
The level of scale The start time, day time
The zoom Zoom range is from the overview of amplification to sample level
memory May be retained within two multichannel input ScopeRecord waveform, for later calls and analysis.
ScopeRecord ™ scroll mode sampling rate and recording time range
Time base scope 4 ~ 2 minutes/ms/frames
Record the time range 4.8 ~ 40 hours
"See all" mode of time/space 0.4 ~ 4 h/s/frames
Capture a short pulse wave interference 8 ns
Sampling rate 125 MS/s
The resolution of the 160 microseconds ~ 4.8 seconds
TrendPlot ™ records
Multi-channel paperless electronic recorder.Graphically, display and storage of up to four automatic oscilloscope measurement results or DMM readings of change over time.
Signal source and display Arbitrary combination oscilloscope measurement (on an arbitrary input channel) or DMM readings (dual channel instrument)
The depth of the storage Each record store 19200 points (group).Records of each sample point including minimum, maximum and average, as well as the date and time stamp.
range Normal view: 5-30 minutes/seconds/frames;On the "view all" mode: 5-48 hours/minutes/frames (overview) any record
Record the time range For 22 days, a resolution of 102 seconds;4 readings for 5.5 days.
Recording mode Continuous recording, from the beginning of the 5 s/case, with automatic timing compression
Measurement speed Automatic measuring 3 or more times per second
The level of scale The start time, day time
The zoom 64 times the most narrow overview (used to display all records), up to 10 x magnification (for maximum limit display details)
memory May be retained within two multichannel input TrendPlot records, for later calls and analysis.
The cursor measurement - all recorder patterns
Signal source Arbitrary waveform display mode (oscilloscope, ScopeRecord or TrendPlot) under any line in the wave
Double vertical line The cursor with the cursor time interval, start time, or recorded in the absolute time together is used to identify any average value, the maximum or minimum of data points.
General technical indicators
190-062. 190-102. 190-202. 190-502. 190-104. 190-204. 190-504.
The input voltage range
Largest floating voltage rating 1000 V / 600 V IV CAT CAT III (any contact with the maximum voltage between the grounding voltage level)
VPS410 - II probes the input voltage 1000 V / 600 V IV CAT CAT III (standard 10:1 the maximum voltage between the probe tip and reference lead)
VPS421 probe input voltage 1000 v / 600 v IV CAT CAT III (probe tip and reference lead and grounding, the maximum voltage between the probe tip and reference lead between the maximum is 2000 v)
The biggest BNC input voltage The CAT IV 300 V (maximum voltage directly BNC input)
Maximum input voltage 1000 V / 600 V IV CAT CAT III
(the safety design of banana input connectors)
-
Memory storage and call
Memory location (built-in) 30 waveform storage, 10 records storage and nine screen copy storage
30 waveform storage Each storage location can contain up to two or four waveform and the corresponding Settings.
10 the record store Each storage location may contain: 100 screen playback sequence, ScopeRecord scroll mode records (2 or 4 trace), or as many as four measuring TrendPlot record
External data storage On the PC雷竞技app using FlukeView ™ - 2 software storage, or stored in an external flash drive directly by USB host port (32 GB)
The screen copy Used on P雷竞技appC FlukeView ™ - 2 software storage, or internal storage () in the instrument, the screen copy can through the USB host port as BMP file is copied to the external flash drive
non-volatile In non-volatile flash ROM to save, and all data is safe, has nothing to do with the battery or power supply condition.
Real time clock For ScopeRecord, 100 screen playback sequence and TrendPlot record provides information on date and time stamp.
The shell
design Solid and shockproof, with one-piece protective holster.The standard wrist belt and belt.
Support kensington lock to lock instrument when unattended.
Waterproof and dustproof IP protection grade, 51 IEC60529 standards
Vibration and shock Impact resistance up to 30 g, vibration resistance (sinusoidal) up to 3 g / 0.03 g2 / Hz (random), accord with MIL - PRF - 28800 - f 2 class standard
The screen size 133 mm x 90 mm (5.3 in x 3.5 in) LCD
The resolution of the 1120 x 765 pixels
brightness The user can be adjusted, up to 300 CD/m2
Mechanical data
size 265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in)
Weight (including battery) 2.1 kg (4.6 lb) 2.2 kg (4.8 lb)
The power supply
Circuit, Enclose BC190/830 universal power adapter/battery charger, with removable type 2 power cords: 100 Vac to 240 Vac, plus or minus 10%, 50 to 60 Hz
Battery power Rechargeable lithium ion batteries (attached).Battery can pass on the back of the instrument is easy to open the battery cover for replacement
The attached battery type and capacity [optional battery] BP290:10.8 V, 2500 mAh
[BP291 (5000 mAh) optional]
BP291:10.8 V, 5000 mAh
Battery marking Battery is equipped with a built-in status identification, and external charger, is located in the instrument next to the battery status identification on the screen.
Low battery life (backlit) When using BP290 (attached), 3.5 hours;When using BP291 (optional), up to seven hours When using BP291 (attached), up to seven hours
Battery charging time When using BP290 for 2 1/2 level hours;When using BP291 for 5 hours When using BP291 for 5 hours
Battery power saving function Automatic "power" and power can be adjusted."Screen off", automatically adjustable power outage time.
The battery power on the screen
security
compliance Pollution EN61010-1, level 2,
IEC 61010-2-030: the CAT III 1000 V, 600 V/CAT IV
Environmental requirements
Working temperature The battery discharge: 0 ° C to 40 ° C (32 ° F to 104 ° F)
Battery: 0 ° C to 40 ° C (32 ° F to 104 ° F)
Storage temperature - 20 ° to 60 ° C (C - 4 ° F to 140 ° F)
humidity 0 ° C to 10 ° C (32 ° F to 50 ° F) : no condensation
10 ° to 30 ° C C (50 ° F to 86 ° F) : 95% (+ / - 5%)
30 ° C to 40 ° C (86 ° F to 104 ° F) : 75% (+ / - 5%)
40 ° C to 50 ° C (104 ° F to 122 ° F) : 45% (+ / - 5%)
Maximum working altitude CAT, CAT III 1000 V, 600 V IV: up to 2000 m (6600 ft)
CAT is 300 V, 600 V CAT III, IV CAT II 1000 V: up to 4000 m (13000 ft)
Largest store elevation 12 km (, 40000 ft)
Electromagnetic compatibility (EMC) IEC 61326-1: industry;
CISPR 11: group 1, A class;
South Korea (KCC) : class A equipment (industrial radio and communication equipment);
The United States (FCC) : 47 CFR part 15 C section.
interface With two USB ports.Port with the floating of the instrument measurement circuit insulation completely.
USB host port connected directly to the external flash memory (up to 32 GB), used to store the waveform data, measurement results, instrument Settings and screen copy.Or, the USB - A port can be used to connect the WiFi adapter in order to realize the wireless PC connection.Provide the Mini USB - B port, a雷竞技appllow interconnection with PC, in order to use the FlukeView - 2 under PC control software for remote control and data transmission.
The probe calibration output With a special probe calibration reference contact output, with arbitrary input channels completely insulation measurement.
Generator output: 1.225 Vpp / 500 Hz square-wave
Warranty period The main instrument for 3 years, 1 year batteries and accessories
Form a complete set of accessories
The battery charger/power adapter BC190/830
Lithium ion battery BP290 (10.8 V, 2500 mAh) BP291 (10.8 V, 5000 mAh)
Voltage probe set.Each set includes grounding wire, hook clamp;VPS410 - II - x also bushing with grounding spring and the probe tip. 2 VPS421 -x rugged industrial-grade probe, 100:1150 MHz, have 4 mm banana with sheath tips and large jaw alligator clip (a red and a blue) 2 VPS410 - II - x 10:1 voltage probe, 500 MHz (a red and a blue) Four VPS421 - x rugged probe, 100:1150 MHz, (red, blue, gray, green) Four VPS410 - II - x 10:1 voltage probe, 500 MHz (a red, a gray, a blue, green)
Test leads TL175 (a red and black), with the test pins -
other Lithium ion battery (see above) for BP290 or BP291,;Battery charger (BC190) with general power cord sets;Hanging belt;Wrist band (the user can choose the left hand or right hand use);About th雷竞技appe user manual and FlukeView ® - 2 demo software package (limited) download information;And the USB cable to PC connection.Feed-through cable termination, 50 Ω (each channel one, and only 190-50 x).
Optional configuration Each model can be "box" to provide (as above), or the optional SCC293 suite.SCC293 include: CXT293 rugged 雷竞技appprotective portable bag, full version FlukeView PC software (including activation code), as well as the WiFi adapter (for the use of FlukeView - 2 software wireless PC connection).
Optional accessories SCC293, VPS101-1:1 voltage probe;VPS510 - x - broadband compact probe;I400s electrical pliers;HH290 hooks;CXT293 protective portable bag;TRM50 - BNC feed-through cable termination, 50 Ω, safety design;EBC290 batteries

Mode雷竞技appl: Fluke 190 Series III ScopeMeter ® Test Tool

ScopeMeter 190-062 - III Test Tool
UPC: 195112021774

The attached:

  • ScopeMeter. 190-062 - III
  • BC190/830 type power adapter
  • The power line
  • BP290 lithium-ion battery pack
  • TL175 test lead group
  • VPS421 probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • Printed instructions
ScopeMeter 190-102 - III Test Tool
UPC: 195112021798

The attached:

  • ScopeMeter. 190-102 - III
  • BC190/830 type power adapter
  • The power line
  • BP290 lithium-ion battery pack
  • TL175 test lead group
  • VPS421 probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • Printed instructions
ScopeMeter 190-104 - III Test Tool
UPC: 195112021828

The attached:

  • ScopeMeter. 190-104 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • VPS421 probe (4 x)
  • Hand with
  • Hang with
  • The USB cable
  • Printed instructions
ScopeMeter 190-202 - III Test Tool
UPC: 195112021842

The attached:

  • ScopeMeter. 190-202 - III
  • BC190/830 type power adapter
  • The power line
  • BP290 lithium-ion battery pack
  • TL175 test lead group
  • VPS410 - II probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • Printed instructions
ScopeMeter 190-204 - III Test Tool
UPC: 195112021866

The attached:

  • ScopeMeter. 190-204 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • VPS410 - II probes (4 x)
  • Hand with
  • Hang with
  • The USB cable
  • Printed instructions
ScopeMeter 190-502 - III Test Tool
UPC: 195112021880

The attached:

  • ScopeMeter. 190-502 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • TL175 test lead group
  • VPS410 - II probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • TRM50 cable termination (2)
  • Printed instructions
ScopeMeter 190-504 - III Test Tool
UPC: 195112021903

The attached:

  • ScopeMeter. 190-504 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • VPS410 - II probes (4 x)
  • Hand with
  • Hang with
  • The USB cable
  • TRM50 cable termination (4)
  • Printed instructions
ScopeMeter 190-062 - III/S Test Tool with the kit
UPC: 195112021781

The attached:

  • ScopeMeter. 190-062 - III
  • BC190/830 type power adapter
  • The power line
  • BP290 lithium-ion battery pack
  • TL175 test lead group
  • VPS421 probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions
ScopeMeter 190-102 - III/S Test Tool with the kit
UPC: 195112021804

The attached:

  • ScopeMeter. 190-102 - III
  • BC190/830 type power adapter
  • The power line
  • BP290 lithium-ion battery pack
  • TL175 test lead group
  • VPS421 probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions
ScopeMeter 190-104 - III/S Test Tool with the kit
UPC: 195112021835

The attached:

  • ScopeMeter. 190-104 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • VPS421 probe (4 x)
  • Hand with
  • Hang with
  • The USB cable
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions
ScopeMeter 190-202 - III/S Test Tool, with a suite
UPC: 195112021859

The attached:

  • ScopeMeter. 190-202 - III
  • BC190/830 type power adapter
  • The power line
  • BP290 lithium-ion battery pack
  • TL175 test lead group
  • VPS410 - II probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions
ScopeMeter 190-204 - III/S Test Tool, with a suite
UPC: 195112021873

The attached:

  • ScopeMeter. 190-204 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • VPS410 - II probes (4 x)
  • Hand with
  • Hang with
  • The USB cable
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions
ScopeMeter 190-502 - III/S Test Tool, with a suite
UPC: 195112021897

The attached:

  • ScopeMeter. 190-502 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • TL175 test lead group
  • VPS410 - II probe (2 x)
  • Hand with
  • Hang with
  • The USB cable
  • TRM50 cable termination (2)
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions
ScopeMeter 190-504 - III/S Test Tool, with a suite
UPC: 195112021910

The attached:

  • ScopeMeter. 190-504 - III
  • BC190/830 type power adapter
  • The power line
  • BP291 lithium-ion battery pack
  • VPS410 - II probes (4 x)
  • Hand with
  • Hang with
  • The USB cable
  • TRM50 cable termination (4)
  • CXT293 portable package
  • DWA - 131 WiFi adapter
  • 雷竞技appFlukeView activate manual (paper)
  • Printed instructions