雷竞技appFluke - 190-502 ScopeMeter ® color digital oscillographic table
The main features
Use double channels雷竞技app and four CAT level IV Fluke ScopeMeter 190 series II for more information, solve more problems.
雷竞技appFluke ScopeMeter 190 series II will be safe level and strong portability combined with desktop oscillographic table of high performance.These rugged ScopeMeter test tools specially designed for plant maintenance engineers and technicians, can under the condition of hard, dirty, dangerous industrial work, test from microelectronics to all devices in the field of power electronics applications.190 series II is an easy to use test tools, you can use it to handle any troubleshooting tasks.Which include multimeter, TrendPlot ™ and ScopeRecord ™ scroll mode of paperless recorder and Connect with - and - View ™ triggered a hands-free operation, there are more features:
- Two or four electrical isolation input
- Security level for 1000 v / 600 v IV CAT CAT III
- 60 MHz, 100 MHz, 200 MHz or 500 MHz bandwidth models to choose from
- Sampling rate is high, up to 5 GS/s, resolution up to 200 ps (depending on the use of models and channel)
- Waveform capture each channel depth storage: 10000 times, so you can magnify the view details
- Dual channel models dedicated 5000 count digital multimeter
- Model through four channels of oscillographic table BNC input four instrument measurement
- Connect - and - View ™ continuous automatic trigger, a single shot, pulse width and video trigger
- ScopeRecord scroll mode, capture the waveform sampling data up to 48 hours
- TrendPlot, trend readings for 22 days
- The advanced automatic measurement, power (Vpwm, VA, W, PF) and time (mAs, V/s and W/s)
- 51, dustproof and waterproof level for IP can be used in harsh environment
- Isolated storage devices and PC USB port can be connected
- Lithium ion battery support longer running time interval:
- 190 - X04, four channel model for 7 hours (standard BP291)
- 190 - X02, dual channel model for 4 hours (standard BP290) or for up to 8 hours (using the option BP291)
- Using an optional external battery charger EBC290 for spare batteries
- Easy to open the battery cover so you can easily replace the battery
- When unattended, available standard Kensington or ® as fixed lock and lock oscillographic table convenient slot
Diagnostic capacity and CAT IV safety level four
雷竞技appFluke ScopeMeter 190 II series handheld oscillographic table adopts double insulated double channels and four floating oscillographic table, security levels suitable for 1000 v / 600 v IV CAT CAT III environment measurements.
Produc雷竞技appts overview: Fluke - 190-502 ScopeMeter ® color digital oscillographic table
雷竞技appFluke 190 series II ScopeMeter ® handheld oscillographic table - ScopeMeter ® test tools more than 20 years of innovation.
As a safe level of 1000 v / 600 v IV CAT CAT III dou雷竞技appble channels and four portable oscillographic table, Fluke 190 series II ScopeMeter ® oscillographic table will level of performance, durability and portability.You can choose to 60 MHz, 100 MHz, 200 MHz or 500 MHz bandwidth model, real-time sampling rate is as high as 5 GS/s, a resolution of 200 ps, each channel deep memory can store 10000 samples, which can realize high precision capture and display waveform details, noise and other distractions.
All the model achieves IP - 51 grade can be dustproof, waterproof, moistureproof and resistance to a wide range of temperature change.
Three phase or at a multiloop industrial system on the timing or amplitude measurement, or in the circuit under test to compare and contrast more test points.Such as TrendPlot ™, ScopeRecord ™ and Connect - and - View ™ feature helps you to quickly diagnose industrial machinery, such as automation and process control devices and power electronic devices, thereby reducing maintenance costs and downtime as much as possible.These features make the oscillographic sheet is easy to use, especially in the diagnosis of intractable problems, such as complex waveform, induction, intermittent events and fluctuations, or noise drift problem.
New type of lithium battery technology can ensure you the oscillographic table available throughout the day.
Produc雷竞技appt specifications: Fluke - 190-502 ScopeMeter ® color digital oscillographic table
Technical indicators | |
---|---|
bandwidth | 雷竞技appFluke 190-504:500 MHz 雷竞技appFluke 190-502:500 MHz 雷竞技appFluke 190-204:200 MHz 雷竞技appFluke 190-202:200 MHz 雷竞技appFluke 190-104:100 MHz 雷竞技appFluke 190-102:100 MHz 雷竞技appFluke 190-062:60 MHz |
The channel number | 雷竞技appFluke. 190-504:500 MHz: 4 channels 雷竞技appFluke 190-502:500 MHz: 2 channels 雷竞技appFluke. 190-204:200 MHz: 4 channels 雷竞技appFluke 190-202:200 MHz: 2 channels 雷竞技appFluke 190-104:100 MHz: 4 channels 雷竞技appFluke 190-102:100 MHz: 2 channels 雷竞技appFluke 190-062:60 MHz: 2 channels |
Real-time sampling rate | 雷竞技appFluke 190-504:5 GS/s 雷竞技appFluke 190-502:5 gs/s 雷竞技appFluke 190-204:2.5 GS/s 雷竞技appFluke 190-202:2.5 GS/s 雷竞技appFluke 190-104:1.25 GS/s 雷竞技appFluke 190-102:1.25 GS/s 雷竞技appFluke 190-062:625 MS/s |
The input | 雷竞技appFluke 190 - X04:4 x BNC input for oscillographic table and multimeter measurement 雷竞技appFluke 190 - X02:2 BNC input and 1 DMM input |
Independent floating input isolation | Up to 1000 V between the input, reference and grounding CAT CAT III / 600 V IV |
Time base scope | Ns/div 1 to 4 s/div (190-504500 MHz model) Ns/div 2 to 4 s/div (190-20 x, 200 MHz model) 5 ns/div to 4 s/div (190-10 x, 100 MHz model) 10 ns/div to 4 s/div (190-062, 60 MHz model) |
The input sensitivity | 2 mV - 100 - V/div and attenuation |
Trigger type | Connect - and - View ™, free operation, a single photo, edge, latency, dual slope, college video, video circuit, pulse width is optional, N cycle |
Trigger source | 雷竞技appFluke 190 - X02:2 BNC input or by DMM external input connection 雷竞技appFluke 190 - X04:Four BNC input |
Electronic pulse capture | 8 ns |
Oscillographic table measurement | The cursor7: Automatically:30 |
Record the length of the largest | ScopeRecord mode: every time input 30000 pt Oscillographic table schema: every time input 10000 pt |
reserved | Digital afterglow provides the oscillographic table similar to the simulation of wave attenuation |
Waveform comparison | With automatic pass/fail test waveform reference |
DMM specifications (type of dual channel) | |
The instrument input (also used as the oscillographic table schema external trigger input) |
4 mm banana plug input and oscillographic table input and grounding is completely isolated |
Maximum resolution | 5000 count |
measurement | Vdc, Vac RMS, Vac + dc RMS, resistance, persistent, diode test, current (by current clamp or shunt), temperature of DHS in C or DHS F (using the optional converter) |
Storage location | Screen + set: 30 store waveform, 10 9 record and store a copy of the screen. |
display | 153 mm quick update of full color LCD |
Environmental indicators | |
Working temperature | 0 DHS C to 40 DHS C (including battery) 0 to 50 DHS DHS C C (including battery) |
Storage temperature | - 20 ° C to + 60 ° C |
Work at an altitude of | The CAT IV III 1000 V, 600 V/CAT up to 2000 m (6666 ft) 600 V / 1000 V II CAT CAT III up to 3000 m (10000 ft) |
Safety specifications < | |
Electrical safety | The CAT CAT III 1000 V / 600 V IV (EN61010-1) |
The mechanical and general specifications | |
size | 270 x 190 x 70 mm |
The weight of the | 2.2 kg |
Warranty period | The host three years warranty |
Lithium ion batteries | 雷竞技appFluke 190 - XX2:BP290 (2400 mah) 雷竞技appFluke 190 - XX4:BP291 (4800 mah) |
Mode雷竞技appls: Fluke - 190-502 ScopeMeter ® color digital oscillographic table
- Color ScopeMeter, 500 MHz
- Four channels
- DMM/Ext.
Manual + 雷竞技appresources: Fluke - 190-502 ScopeMeter ® color digital oscillographic table
- The 190 Series II | user manual
- The 190 Series II | user manual addendum
- The 190 Series II statement | non-volatile memory
- The 190 Series II | product technical indicators
- The 190 Series II | maintenance manual
- The 190 Series II | maintenance manual addendum
- EBC290 | instructions page
- HH290 | instructions page
- F190 oscillographic table: the characteristics of real-time sampling rate index and application | technology application
- A new kind of ScopeMeter 190 c series products | technology application
- Use of F190 new universal oscillographic table for fault diagnosis
- Th雷竞技appe use of Fluke 190 c series testing tool for pulse width trigger | technology application
- Using measurement power | ScopeMeter190 series oscillographic table technology application
- Capture of intermittent signal on hand-held oscillograph | technology application
- For explosion-proof company, the precision of the test tool is vital | technology application
- Hand-held oscillograph in the application of mobile communication power supply computer maintenance | technology application
- Handheld oscillographic table used for the daily maintenance of telecom service providers and diagnosis | technology application
- Basic knowledge of digital storage oscilloscope | technology application
- Measuring no public reference potential signal | technology application
- Oscilloscope storage capacity and storage management methods | technology application
- Oscillographic table | alternator test technology application
- Oscillographic table make debugging easier | technology application
- Oscillographic table to capture the waveform abnormal | technology application
- Oscillographic table check timing driving | technology application
- Oscillographic table to measure the motor shaft voltage current | technology application
- Oscillographic table measuring power | technology application
- Oscillographic table abnormal decrypt the drive | technology application
- Oscillographic table pulse-width trigger | technology application
- Fluke oscillographic table in the application of the fieldbus technology training certification | technology application
- Fluke oscillographic table accurate measurement of the variable frequency drive system | technology application
- Work hard - 190 series oscilloscope table | technology application in the field of heavy industry
- Input channel isolation function advantage | technology application in practical application
- Sound engineer to maintain the fidelity of the concert hall | application