China

雷竞技appFluke 1630-2 FC earth loop resistance test clamp table

  • 雷竞技appFluke 1630-2 FC Earth Ground Clamp
  • 雷竞技appFluke 1630-2 FC Earth Ground Clamp
  • 雷竞技appFluke 1630-2 FC Earth Ground Clamp
  • 雷竞技appFluke 1630-2 FC Earth Ground Clamp

The main features

  • For fast and safely test indoor/outdoor ground loop resistance, support the use of no auxiliary measuring method
  • Ac leakage current measurements: constantly open grounding system grounding rods, can measure ac leakage
  • Durable: in the scene of bad environment, heavy jaw still can keep the precision and durable
  • Record measurements: save up to 32760 measurements in the memory
The spot
selections11552.00
Tax-inclusive price
Fluke authentic guarantee
With $200 free shipping
Enjoy the return within 7 days

Produc雷竞技appts overview: Fluke 1630-2 FC earth loop resistance test clamp table

Grounding resistance test is located in the narrow space inside the equipment (including indoor or do not allow the use of auxiliary grounding area).Keep online - identify grounding resistance, without interruption from the system after opening grounding connection again.

雷竞技appFluke 1630-2 FC ground loop resistance test clamp table with a Fluke tools consistent high quality and durability.Durable clamp table jaw even in the daily operation of the industrial environment can guarantee accurate and durable.

No auxiliary measuring method

1630-2 FC clamp table more than double jaw is used to measure the grounding resistance of grounding system., you don't have to perform dangerous using the test technology and time-consuming to disconnect and connect the ground loop operation, also don't have to find the suitable location to install auxiliary grounding for testing.You can also difficult position before the execution of the grounding test: building interior, cable tower or unable to contact the soil in place of any auxiliary grounding position.

雷竞技appFluke Connect®Wireless systems

1630-2 FC sup雷竞技appport Fluke Connect wireless system (not in all regions are provided).雷竞技appFluke Connect using the application on the smart phone or tablet wirelessly connected clamp table.The application can be on your smartphone or tablet screen earthing resistance measurements.You can use these measurements雷竞技app, GPS location from your phone and images stored in a Fluke Connect Cloud storage, and share them with your team.

Produc雷竞技appt specifications: Fluke 1630-2 FC earth loop resistance test clamp table

Electrical technical indicators
The largest ground voltage 1000 V
The battery type AA alkaline IEC/EN LR6 (x4)
Battery life * for more than 15 hours
* in grounding resistance measurement mode, the back light and radio frequency mode off
Frequency range 40 Hz to 1 kHz
Protection grade IEC/EN 60529: IP30 (jaw closed)
LCD display The digital reading 9999 count
The refresh rate 4 / SEC.
Working temperature - 10 ° C to + 50 ° C
Storage temperature - 20 ° C to + 60 ° C
Working humidity The condensation (< 10 ° C) (< 50 ° F)
90% RH or less (10 ° to 30 ° C C / 50 ° F to 86 ° F)
75% RH or less (30 ° C to 40 ° C / 86 ° F to 104 ° F)
45% RH or less (40 ° C to 50 ° C / 104 ° F to 122 ° F)
(condensate)
Work at an altitude of 2000 m (6561 ft)
For altitude 12, 000 m (39370 ft)
Reference temperature 23 ° C + / - 5 ° C (73 ° F + 9 ° F) for
The temperature coefficient of 0.15% (x) specified precision / ° C (18 ° C or > < 28 ° C [< 64.4 ° F or > 82.4 ° F])
Overload indicator OL
Data record capacity A minimum of 32760 measurements
Data record time interval 1 second to 59 minutes and 59 seconds
According to the standard loop resistance reading specifications
Input (Ω) The minimum The biggest
0.474 0.417 0.531
0.5 0.443 0.558
10 "=" 9.55 10.45
= "100" = "96" = "104"
security
general IEC/EN 61010-1 level pollution IEC/EN 61557-1
measurement IEC/EN 61010-2-032: the CAT III 1000 V, 600 V/CAT IV
Current clamp table for leakage current measurement IEC/EN 61557 - lift, 30 A/m or less
Grounding resistance IEC/EN 61557-5
The effectiveness of the protective measures IEC/EN 61557-16
Electromagnetic compatibility (EMC) The international standard IEC/EN 61326-1: portable electromagnetic environment
CISPR group B class, therefore the IEC/EN 61326-2-2
South Korea's (KCC) Class A equipment (industrial radio and communication equipment)
The United States (FCC) 47 CFR part 15 B child.According to the provisions of article 15.103 of this product is regarded as tax-free equipment
radio
Frequency range 2412 MHz to 2462 MHz
The output power The < 10 mW
Radio frequency certification The FCC ID: T68 - FBLE IC: 6627 a - FBLE
General technical indicators
Conductor size About 40 mm (1.57 in)
Size (length x width x height) 283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)
The weight of the 880 g (31 oz)
Warranty period 1 year
Ground loop resistance
range precision= "1"Plus or minus (+ / - % + Ω reading value)
0.025 Ω to Ω 0.249 1.5% + 0.02 Ω
0.250 Ω to Ω 0.999 1.5% + 0.05 Ω
1.000 Ω to Ω 9.999 1.5% + 0.10 Ω
10.00 Ω to Ω 49.99 1.5% + 0.30 Ω
50.00 Ω to Ω 99.99 1.5% + 0.50 Ω
100.0 Ω to Ω 199.9 3.0% + 1.0 Ω
200.0 Ω to Ω 399.9 5.0% + 5.0 Ω
400 Ω Ω to 599 10.0% + 10 Ω
600 Ω Ω to 1500 20.00%
= "1"Loop resistance, inductance, center conductors and jaw with vertical
After mA floor drain current measurements
Automatic range 50/60 Hz, true RMS, wave coefficient CF 3 or less
range The resolution of the precision= "1"Plus or minus (+ / - % reading value + mA)
0.200 mA to 3.999 mA 1 mu A 2.0% + 0.05 mA
4.00 mA to 39.99 mA 10 mu A 2.0% + 0.03 mA
40.0 mA to 399.9 mA 100 mu A 2.0% + 0.3 mA
0.400 A and 3.999 A 1 mA 2.0% + 3 mA
4.00 A and 39.99 A 10 mA, 2.0% + 30 mA
= "1"Apply to the signal frequency
  • 40 Hz to 1 kHz (filter is set to "off")
  • 40 Hz and 70 Hz (when filter is set to "on")

Mode雷竞技appl: Fluke 1630-2 FC earth loop resistance test clamp table

雷竞技appFLUKE FC - 1630-2
  • 1630-2 FC earth loop resistance test clamp table
  • Hard suitcases
  • Standard calibration loop resistance plate
  • 4 AA batteries
  • Safety information guide and quick reference guide

雷竞技appFluke Connect is not in all countries/regions are provided.

* not all models are available in all countries/regions.Please consult your local representative fluke.

©Fluke companies.All trademarks are the property of their respective owner.When buying is not attached to provide smart phones, wireless services and data package, etc.The first 5 GB free.Compatible models: running iOS 8 or higher version of the iPhone 4 s, and more advanced models;The device (using the iPhone architecture);Run Android 4.3 x or higher version of the Samsung Galaxy S4, and run Android ™ 4.4 x or higher version of the Samsung Galaxy S, Nexus 5, HTC One and One M8.Both Apple and Apple logo for the company in the United States and other countries/regions registered trademark.App Store is a service mark of apple, Google Play is Google the company's trademark.