雷竞技appFluke 289 IMSK industrial multimeter repair kit
The main features
- By manual and automatic range adjustment, display, automatic keep records and minimum/maximum and average achieve true RMS accuracy and provide the result of what you need.
- 雷竞技appFluke - i400 400 a ac current clamp can be transformed into 289 clamp table.
- CAT, CAT IV 600 V, 1000 V safety grade III instrument allows you to obtain reliable safety at work.
Produc雷竞技appts overview: Fluke 289 IMSK industrial multimeter repair kit
The composi雷竞技appte suite building foundation multimeter Fluke Fluke for next generation high performance industrial records 289 and i400 ac current clamp.These products can help together to solve the electronic equipment, factory automation, power distribution and complex problems in mechanical and electrical equipment.The suite to accompany special accessories, compared with the separate sales of products, can improve the work efficiency and save more than 15% of the cost.
雷竞技appThe characteristics of the Fluke 289 digital multimeter
- Provide data and graphically display the results of function
- TrendCapture (captured) function can be graphically display data recording session, to rapidly determine whether appear abnormal situation.
- Through the onboard TrendCapture (capture) function to check as many as 10000 record events and record the readings
- Trend amplification function to provide users with an unprecedented way to view and analysis by TrendCapture (capture) function to capture the data;The biggest can enlarge 14 times.
- Low pass filter can accurately measure speed regulating motor driven equipment at the same time on the signal-to-noise ratio (SNR) or other electrical equipment voltage and frequency.
- The attached quality test wires, alligator clip and current plugs
雷竞技appThe characteristics of the Fluke i400 alternating current clamp
- Provide up to 400 A accurate ac current measurements, without having to disconnect the circuit.
- Flexible thermal test wires and alligator clip is the powerful supplement of high-performance suite.
- Soft slippery bag film handle to prevent accidental contact with live circuit
- 32 mm diameter wire
1000 v voltage detection range, suitable for wide applications
- Measure up to 1000 V ac/dc voltage
- To measure up to 10 A ac/dc current
- Measuring 500 M Ω resistance
- To measure up to 1000 kHz frequency
Security features
- The CAT III level of 1000 V, provide additional protection
- CAT 600 V grade IV, provide additional protection
- CE and CSA certification
Produc雷竞技appt specifications: Fluke 289 IMSK industrial multimeter repair kit
The specifications of the 289 | ||
function | ||
Dc voltage | Range/resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic precision | 0.025% | |
Ac voltage | Range/resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic precision | True RMS (0.4%) | |
Dc current | Range/resolution | (including 500.00 A and 50.000 A, 5000.0 (including mA, mA, 5.0000 A, 10.000 A 400.00 |
Basic precision | 0.05% | |
Alternating current | Range/resolution | (including 500.00 A and 50.000 A, 5000.0 (including mA, mA, 5.0000 A, 10.000 A 400.00 |
Basic precision | True RMS (0.6%) | |
Temperature (excluding probe) | Range/resolution | 200.0 ° and 1350.0 ° C C ° F (328.0 to 2462.0 ° F) |
Basic precision | 1.0% | |
resistance | Range/resolution | 50.000 Ω, 500.00 Ω Ω Ω, 5.0000 k, 50.000 k, 500.00 k Ω Ω, 5.0000 M, 50.00 M Ω Ω, 500.0 M |
Basic precision | 0.05% | |
capacitance | Range/resolution | NF, 10.00 the nF, nF, 1.000, 100.0 1.000 (including 100.0, 10.00 (including F, F (including F, 1000 (including F, mF, 10.00 100 mF |
Basic precision | 1.0% | |
frequency | Range/resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Basic precision | 0.005% | |
connectivity | Opt雷竞技appional Fluke ir3000 FC infrared connector |
General technical indicators | ||
The highest voltage between any terminal and earthing | 1000 V | |
The battery type | 6 AA alkaline batteries, NEDA IECLR6 15 a | |
Battery life | The shortest 100 hours, 200 hours record mode | |
The temperature | work | - 20 ° C to 55 ° C |
store | To 40 ° to 60 ° C C | |
Relative humidity | 0 to 90% 37 ° C) on the (0, 0 to 65% (37 ° to 45 ° C) C, 0 to 45% (45 ° C to 55 ° C) | |
Electromagnetic compatibility | EMC EN61326-1 | |
vibration | MIL - PRF - 28800 - f 2 levels of random vibration | |
impact | 1 meter high drop test, according to the third edition standard IEC 61010-1 | |
Size (height x width x length) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
The weight of the | 28 oz (870.9 g) | |
Screen display multiple sets of data | is | |
True RMS communication bandwidth | 100 kHz | |
DBV/dBm | is | |
Dc voltage resolution | 1 mu V | |
The resistance range | As high as 500 M Ω | |
conductance | 50.00 nS | |
On-off test buzzer | is | |
Battery/fuse inspection door | There are / | |
Timing clock | is | |
Calendar clock | is | |
The average minimum and maximum - | is | |
Duty ratio | is | |
The pulse width | is | |
Isolation fiber interface | is | |
Auto/touch | is | |
Reading the memory | is | |
Login to the PC | is | |
Interval/event log | is | |
Record the memory | As many as 15000 readings | |
A wireless connection (optional) |
Spe雷竞技appcification: Fluke i400 alternating current clamp | |
Rated current range | 400 A |
Continuous current range | 1 A - 400 - A |
Most current nondestructive | 1000 A |
The minimum current can be obtained | 1 A |
Basic precision | 2% + 0.06 A |
(45-400 Hz) | |
Percentage (reading) + minimum specifications | |
Frequencies available | 5 Hz - 20 kHz |
The output value | 1 mA/A |
Security technology parameters | |
security | The CAT IV III 1000 V 600 V, the CAT |
Maximum voltage | Ac 1000 V RMS grounding, in line with EN61010 |
The mechanical and general specifications | |
The warranty period | 1 year |
The largest diameter of wire | 32 mm (1.25 in) |
The biggest wire size (bus) | 750 MCM |
The output cable length | 1.5 m (59) in |
Belt sheathed banana plug | is |
Mode雷竞技appl: Fluke 289 IMSK industrial multimeter repair kit
雷竞技app/ IMSK FLUKE - 289
雷竞技appFluke 289 IMSK industrial multimeter repair kit
Include:
- 雷竞技appFluke 289 true RMS multimeter data records
- 雷竞技appFluke i400 400 a alternating current clamp
- TL71 flexible silica gel test lead group
- AC175 thread alligator clip group
Requi雷竞技appres the use of Fluke ir3000 FC infrared connector Fluke Connect communications